DRV pressure reducing valves for water, air and gases up to 40 bar

DRV pressure reducing valves by the manufacturer Berluto reduce the pressure of water, compressed air or a neutral gas from an industrial network – up to 25 or 40 bar – to the set pressure and keep it constant. The body is made of gunmetal, and a pressure gauge is included.
Three versions cover outlet pressures of 0.2 to 20 bar, eight sizes threads from G 1/4" to G 2". The valves are designed for industrial networks – they are not approved for drinking water and are not for steam or flammable gases.
Three versions
Choose the version according to the pressure you want to set and the pressure in the network.
| Version | Inlet pressure | Outlet | Pressure gauge | Reduction ratio | Control | Spring housing |
|---|---|---|---|---|---|---|
| DRV 250 (low-pressure) | 25 bar | 0.2–2 bar | 0–2.5 bar | 20 : 1 | diaphragm | gunmetal |
| DRV 200 (standard) | 25 bar | 1.5–8 bar | 0–10 bar | 10 : 1 | diaphragm | brass / grey cast iron |
| DRV 225 (high-pressure) | 40 bar | 1.5–20 bar | 0–25 bar | 6 : 1 | piston | brass / grey cast iron |
The minimum difference between inlet and outlet pressure is 1 bar. Reduction ratio = maximum ratio of inlet to outlet pressure. On DRV 200 and DRV 225, the spring housing of sizes G 1 1/4" to G 2" is made of grey cast iron.
All DRV pressure reducing valves
| Code | Thread | Control range | Inlet pressure | kvs (water) | L × H2 | Weight |
|---|---|---|---|---|---|---|
| DRV200-14 | G 1/4" | 1.5–8 bar | 25 bar | 0.5 m³/h | 70 × 165 mm | 0.9 kg |
| DRV200-38 | G 3/8" | 1.5–8 bar | 25 bar | 0.6 m³/h | 70 × 169 mm | 0.85 kg |
| DRV200-12 | G 1/2" | 1.5–8 bar | 25 bar | 1.2 m³/h | 85 × 190 mm | 1.1 kg |
| DRV200-34 | G 3/4" | 1.5–8 bar | 25 bar | 1.3 m³/h | 85 × 190 mm | 1.1 kg |
| DRV200-10 | G 1" | 1.5–8 bar | 25 bar | 1.6 m³/h | 95 × 242 mm | 1.8 kg |
| DRV200-114 | G 1 1/4" | 1.5–8 bar | 25 bar | 4.2 m³/h | 104 × 324 mm | 4.2 kg |
| DRV200-112 | G 1 1/2" | 1.5–8 bar | 25 bar | 4.5 m³/h | 108 × 324 mm | 4.3 kg |
| DRV200-20 | G 2" | 1.5–8 bar | 25 bar | 7.2 m³/h | 147 × 377 mm | 7.0 kg |
| DRV250-14 | G 1/4" | 0.2–2 bar | 25 bar | 0.5 m³/h | 70 × 187 mm | 1.0 kg |
| DRV250-38 | G 3/8" | 0.2–2 bar | 25 bar | 0.6 m³/h | 70 × 187 mm | 1.0 kg |
| DRV250-12 | G 1/2" | 0.2–2 bar | 25 bar | 1.2 m³/h | 85 × 253 mm | 2.5 kg |
| DRV250-34 | G 3/4" | 0.2–2 bar | 25 bar | 1.3 m³/h | 85 × 253 mm | 2.5 kg |
| DRV250-10 | G 1" | 0.2–2 bar | 25 bar | 1.6 m³/h | 95 × 290 mm | 4.4 kg |
| DRV250-114 | G 1 1/4" | 0.2–2 bar | 25 bar | 4.2 m³/h | 104 × 329 mm | 8.0 kg |
| DRV250-112 | G 1 1/2" | 0.2–2 bar | 25 bar | 4.5 m³/h | 108 × 329 mm | 8.0 kg |
| DRV250-20 | G 2" | 0.2–2 bar | 25 bar | 7.2 m³/h | 147 × 380 mm | 14.0 kg |
| DRV225-14 | G 1/4" | 1.5–20 bar | 40 bar | 0.5 m³/h | 70 × 194 mm | 1.2 kg |
| DRV225-38 | G 3/8" | 1.5–20 bar | 40 bar | 0.6 m³/h | 70 × 194 mm | 1.2 kg |
| DRV225-12 | G 1/2" | 1.5–20 bar | 40 bar | 1.2 m³/h | 85 × 228 mm | 1.7 kg |
| DRV225-34 | G 3/4" | 1.5–20 bar | 40 bar | 1.3 m³/h | 85 × 228 mm | 1.7 kg |
| DRV225-10 | G 1" | 1.5–20 bar | 40 bar | 1.6 m³/h | 95 × 252 mm | 2.7 kg |
| DRV225-114 | G 1 1/4" | 1.5–20 bar | 40 bar | 4.2 m³/h | 104 × 362 mm | 7.0 kg |
| DRV225-112 | G 1 1/2" | 1.5–20 bar | 40 bar | 4.5 m³/h | 108 × 362 mm | 6.0 kg |
| DRV225-20 | G 2" | 1.5–20 bar | 40 bar | 7.2 m³/h | 147 × 400 mm | 10.0 kg |
kvs = water flow rate in m³/h at a pressure drop of 1 bar with the valve fully open (manufacturer Berluto). L = length, H2 = overall height (drawing below).
How to choose a DRV pressure reducing valve
- Outlet pressure. You set 0.2–2 bar with the low-pressure DRV 250, 1.5–8 bar with the standard DRV 200 and 1.5–20 bar with the high-pressure DRV 225.
- Inlet pressure. DRV 200 and DRV 250 withstand 25 bar, DRV 225 40 bar. The inlet must be at least 1 bar higher than the outlet and no more than 10× (DRV 200), 20× (DRV 250) or 6× (DRV 225) higher.
- Size according to the flow rate. For water, Q = kvs × √Δp applies: a valve with kvs 1.2 m³/h passes about 2.4 m³/h fully open at a pressure drop of 4 bar. For water, the manufacturer assumes lower flow rates – choose with a reserve.
- Thread. The sizes have a female G thread according to ISO 228 – choose it according to the pipework, but check the flow rate against the kvs value.
Example: a cooling water network has 10 bar, a machine needs 4 bar and no more than 25 l/min. At a pressure drop of 6 bar, DRV200-38 (kvs 0.6 m³/h) passes about 24 l/min fully open – with no reserve. With a reserve, DRV200-12 (kvs 1.2 m³/h) is suitable.
Not sure which regulator to choose? Try the pressure regulator selector – based on line pressure, required pressure and flow.
#showmore#
Flow diagram

The manufacturer’s diagram shows how much water flows through the fully open valve at a given pressure drop. At a pressure drop of 1 bar, the flow rate equals the kvs value; at four times the pressure drop it doubles. At your pressure drop, the required flow rate should lie well to the left of the line for the chosen size – during control the valve is not fully open.
What DRV valves are for – and what they are not for
Yes
- industrial networks for water and neutral non-sticky liquids (the manufacturer assumes lower flow rates)
- compressed air and nitrogen
- neutral non-flammable gases
- medium temperature −15 to +100 °C, with the supplied pressure gauge up to +60 °C
No
- drinking water – the manufacturer does not state approval for drinking water
- steam
- flammable gases
- oxygen – the manufacturer does not state approval
How a pressure reducing valve works

- With the adjusting head you tension the spring, which opens the valve – the medium flows from the inlet to the outlet.
- The outlet pressure pushes against the spring on the diaphragm (DRV 225 on the piston). When it reaches the set value, the valve partially closes and lets through only as much as is being drawn off.
- The pressure gauge shows the outlet pressure. The G 1/4" pressure gauge connection is on both sides of the body.
- The valve has no secondary venting: when you reduce the set pressure, the outlet pressure only drops once medium is drawn off.
Dimensions

L is the length between the connection faces, H1 the height of the pipe axis above the base and H2 the overall height including the adjusting head. The dimensions of all sizes are in the table above and on the page of each valve.
Installation and adjustment
- connect the valve according to the arrow on the body; any mounting position is possible, the manufacturer recommends vertical
- flush or blow out the pipework before installation – dirt will damage the valve seat
- you can move the pressure gauge to the other side of the body – the G 1/4" connection is on both sides
- set the pressure with the adjusting head while a small amount is being drawn off, then check it on the pressure gauge
- the internal parts are replaceable – for worn seals, there is a seal kit for each version and size
Seal kits
Each valve has its own seal kit according to version and size.
| Size | DRV 200 | DRV 250 | DRV 225 |
|---|---|---|---|
| G 1/4" | DRV200-14REP | DRV250-14REP | DRV225-14REP |
| G 3/8" | DRV200-38REP | DRV250-38REP | DRV225-38REP |
| G 1/2" | DRV200-12REP | DRV250-12REP | DRV225-12REP |
| G 3/4" | DRV200-34REP | DRV250-34REP | DRV225-34REP |
| G 1" | DRV200-10REP | DRV250-10REP | DRV225-10REP |
| G 1 1/4" | DRV200-114REP | DRV250-114REP | DRV225-114REP |
| G 1 1/2" | DRV200-112REP | DRV250-112REP | DRV225-112REP |
| G 2" | DRV200-20REP | DRV250-20REP | DRV225-20REP |
Series specifications
| Parameter | Value |
|---|---|
| Inlet pressure | max. 25 bar (DRV 200 and 250), max. 40 bar (DRV 225) |
| Outlet pressure | 1.5–8 bar (DRV 200), 0.2–2 bar (DRV 250), 1.5–20 bar (DRV 225) |
| Maximum reduction ratio | 10 : 1 (DRV 200), 20 : 1 (DRV 250), 6 : 1 (DRV 225) |
| Minimum pressure difference | 1 bar |
| kvs (water) | 0.5 to 7.2 m³/h depending on the size |
| Connection | G 1/4" to G 2" female thread (ISO 228) |
| Pressure gauge | ⌀ 50 mm included, G 1/4" connection on both sides |
| Control | diaphragm (DRV 200 and 250), piston (DRV 225) |
| Secondary venting | no |
| Medium | water and neutral non-sticky liquids, compressed air, nitrogen, neutral non-flammable gases; not steam |
| Operating temperature | −15 to +100 °C, with pressure gauge max. +60 °C |
| Material | body gunmetal CC499K, spring housing brass or grey cast iron (DRV 250 gunmetal), diaphragm and seals NBR/CR |
| Mounting position | any, preferably vertical |
| Conformity | Pressure Equipment Directive 2014/68/EU |
Ventilek advises
Choose a pressure reducing valve according to the flow rate, not according to the pipe thread. And with water, bear in mind that DRV valves are for industrial networks – they are not for drinking water installations in houses.
- compressed air with venting and high flow rate: air pressure regulators
- shutting off water, air and gas: ball valves
- high pressure from a cylinder or network: high-pressure regulators
- Can I use a DRV valve for drinking water?
- No. The manufacturer does not state approval for drinking water. DRV valves are for industrial water, air and neutral gas networks.
- What is the difference between DRV 200, 225 and 250?
- The outlet pressure range and the inlet pressure: DRV 250 sets 0.2–2 bar, DRV 200 1.5–8 bar (both inlet 25 bar) and DRV 225 1.5–20 bar with an inlet of up to 40 bar. DRV 225 controls with a piston, the others with a diaphragm.
- How much air does the valve let through?
- The manufacturer only specifies kvs for water. For air, when the outlet is below half the inlet (absolute), approximately Q [l/min] ≈ 13.4 × kv [l/min] × p1 [bar abs.] applies. This is an approximate estimate for a fully open valve, not a figure from the manufacturer.
- Is the pressure gauge included?
- Yes, a ⌀ 50 mm pressure gauge with a scale of 0–10 bar (DRV 200), 0–2.5 bar (DRV 250) or 0–25 bar (DRV 225).
- Why must the pressure difference not be less than 1 bar?
- The valve needs a pressure drop of at least 1 bar to control. If the inlet is only slightly higher than the set outlet, the valve cannot hold the pressure.
Technical data according to the manufacturer Berluto Armaturen-Gesellschaft (data sheets DRV 200, 225 and 250). The air flow rate is our approximate calculation, not a figure from the manufacturer.
You will find more regulators in the category air pressure regulators.
Product sorting
List of products
Berluto DRV 200 pressure reducing valve (standard version) made of gunmetal for industrial water, air and neutral gas networks.connection G 1 1/2" (female thread)outlet 1.5–8...
Berluto DRV 200 pressure reducing valve (standard version) made of gunmetal for industrial water, air and neutral gas networks.connection G 1 1/4" (female thread)outlet 1.5–8...
Berluto DRV 200 pressure reducing valve (standard version) made of gunmetal for industrial water, air and neutral gas networks.connection G 1" (female thread)outlet 1.5–8 bar,...
Berluto DRV 200 pressure reducing valve (standard version) made of gunmetal for industrial water, air and neutral gas networks.connection G 1/2" (female thread)outlet 1.5–8 bar,...
Berluto DRV 200 pressure reducing valve (standard version) made of gunmetal for industrial water, air and neutral gas networks.connection G 1/4" (female thread)outlet 1.5–8 bar,...
Berluto DRV 200 pressure reducing valve (standard version) made of gunmetal for industrial water, air and neutral gas networks.connection G 2" (female thread)outlet 1.5–8 bar,...
Berluto DRV 200 pressure reducing valve (standard version) made of gunmetal for industrial water, air and neutral gas networks.connection G 3/4" (female thread)outlet 1.5–8 bar,...
Berluto DRV 200 pressure reducing valve (standard version) made of gunmetal for industrial water, air and neutral gas networks.connection G 3/8" (female thread)outlet 1.5–8 bar,...
Berluto DRV 225 pressure reducing valve (high-pressure version) made of gunmetal for industrial water, air and neutral gas networks.connection G 1 1/2" (female thread)outlet...
Berluto DRV 225 pressure reducing valve (high-pressure version) made of gunmetal for industrial water, air and neutral gas networks.connection G 1 1/4" (female thread)outlet...
Berluto DRV 225 pressure reducing valve (high-pressure version) made of gunmetal for industrial water, air and neutral gas networks.connection G 1" (female thread)outlet 1.5–20...
Berluto DRV 225 pressure reducing valve (high-pressure version) made of gunmetal for industrial water, air and neutral gas networks.connection G 1/2" (female thread)outlet...
Berluto DRV 225 pressure reducing valve (high-pressure version) made of gunmetal for industrial water, air and neutral gas networks.connection G 1/4" (female thread)outlet...
Berluto DRV 225 pressure reducing valve (high-pressure version) made of gunmetal for industrial water, air and neutral gas networks.connection G 2" (female thread)outlet 1.5–20...
Berluto DRV 225 pressure reducing valve (high-pressure version) made of gunmetal for industrial water, air and neutral gas networks.connection G 3/4" (female thread)outlet...
Berluto DRV 225 pressure reducing valve (high-pressure version) made of gunmetal for industrial water, air and neutral gas networks.connection G 3/8" (female thread)outlet...
Berluto DRV 250 pressure reducing valve (low-pressure version) made of gunmetal for industrial water, air and neutral gas networks.connection G 1 1/2" (female thread)outlet...
Berluto DRV 250 pressure reducing valve (low-pressure version) made of gunmetal for industrial water, air and neutral gas networks.connection G 1 1/4" (female thread)outlet...
Berluto DRV 250 pressure reducing valve (low-pressure version) made of gunmetal for industrial water, air and neutral gas networks.connection G 1" (female thread)outlet 0.2–2...
Berluto DRV 250 pressure reducing valve (low-pressure version) made of gunmetal for industrial water, air and neutral gas networks.connection G 1/2" (female thread)outlet 0.2–2...
Berluto DRV 250 pressure reducing valve (low-pressure version) made of gunmetal for industrial water, air and neutral gas networks.connection G 1/4" (female thread)outlet 0.2–2...
Berluto DRV 250 pressure reducing valve (low-pressure version) made of gunmetal for industrial water, air and neutral gas networks.connection G 2" (female thread)outlet 0.2–2...
Berluto DRV 250 pressure reducing valve (low-pressure version) made of gunmetal for industrial water, air and neutral gas networks.connection G 3/4" (female thread)outlet 0.2–2...
Berluto DRV 250 pressure reducing valve (low-pressure version) made of gunmetal for industrial water, air and neutral gas networks.connection G 3/8" (female thread)outlet 0.2–2...