Simalube multipoint 5×8 ml – empty 5 lubrication points · empty for own filling
Code: SLM-5X8-00Product detailed description
Simalube multipoint 5×8 ml – empty

simalube multipoint supplies lubricant to 5 lubrication points for up to 1 year with the same reliability as single-point simalube lubricators. The filling consists of five chambers of 8 ml for your own filling with the lubricant prescribed by the machine; each supplies its own hose. Thanks to the snap-on connector it is very easy to replace once empty.
- versatile lubricator for linear guides
- very small dose over a long time
- snap-on connector and quick connectors for Ø 4 mm hoses
- stepless 1–12 months
Why a multipoint instead of five lubricators
- For five nearby lubrication points one activation and one replacement are enough — instead of five.
- Very small doses over a long time, exactly what linear guides need.
- Replacement without loosening hoses: the empty multipoint snaps off, the new one snaps on.
- Same drive and reliability as single-point lubricators: gas cell, max. 5 bar, −20 to +55 °C.
How the multipoint lubricates

The filling is divided into five chambers of 8 ml and each supplies its own hose, so all five points are lubricated at the same time. At a 1-month setting this is roughly 0.27 ml per day per point, at 12 months roughly 0.02 ml. You connect the hoses with quick connectors directly into the lubrication points of the carriages or the nut. Where there are fewer than five lubrication points, a single-point 15 ml lubricator is simpler.
Dose per lubrication point
| simalube multipoint — approximate dose by setting (calculated from 8 ml per outlet) | |||||
|---|---|---|---|---|---|
| Setting | 1 month | 3 months | 6 months | 9 months | 12 months |
| Per 1 lubrication point | ~0.27 ml/day | ~0.09 ml/day | ~0.04 ml/day | ~0.03 ml/day | ~0.02 ml/day |
| Total 5 points | ~1.33 ml/day | ~0.44 ml/day | ~0.22 ml/day | ~0.15 ml/day | ~0.11 ml/day |
The real dose is affected by the ambient temperature, back pressure in the hoses and lubricant viscosity — just like with single-point lubricators. At low temperatures set a shorter time, in the heat a longer one.
Specifications
| simalube multipoint SLM-5X8-00 | |
|---|---|
| Volume | 5 × 8 ml |
| Lubricant | empty for own filling |
| Lubrication points | 5 |
| Dispensing time | stepless 1–12 months |
| Drive | hydrogen gas producing dry cell |
| Working pressure | max. 5 bar |
| Ambient temperature | −20 °C to +55 °C |
| Dimensions | Ø 52 × 109 mm, connector 16.5 mm |
| Hose | Ø 4/2.7 mm, 5 outlets |
| Weight full / empty | ~147 g / ~120 g |
| Storage | recommended 20 °C ± 5 °C |
Multipoint fillings
| simalube multipoint 5 × 8 ml fillings | |||
|---|---|---|---|
| Code | Filling | Lubricant temperature | Where |
| SLM-5X8-00 | empty for own filling | depends on filling | lubricant prescribed by the machine |
| SLM-5X8-01 | multi-purpose grease, lithium/calcium | −30 °C to +120 °C | linear guides, carriages, spindle nuts |
| SLM-5X8-06 | fluid grease | −30 °C to +100 °C | guides needing a free-flowing grease |
| SLM-5X8-10 | food grade grease NSF H1, aluminium complex | −40 °C to +120 °C | food and packaging machines |
| SLM-5X8-14 | chain oil, mineral | −10 °C to +90 °C | chains and linear guides |
| SLM-5X8-18 | food grade oil NSF H1, synthetic | −15 °C to +150 °C | food machines — chains and guides |
Mounting step by step
- Screw quick connectors for Ø 4 mm hose (G 1/8, G 1/4, M5 or M6) into the lubrication points of the carriages and the nut.
- Cut the Ø 4/2.7 mm hoses to the required length, route them without sharp bends and pre-fill them with the same lubricant.
- Push the hoses into the SLM connector (5 × Ø 4 mm) and into the quick connectors.
- Set the time of 1–12 months on the multipoint and write down the activation date.
- Snap the multipoint onto the connector. When empty you just replace it, the hoses stay.
What goes with the multipoint
- SLM connector 5 × Ø 4 mm — snaps onto the lubricator
- Quick connectors for Ø 4 mm hose with G 1/8, G 1/4, M5 or M6 thread into the lubrication points
- Hose Ø 4/2.7 mm by the metre
- Drive unit SLM-5006 for refilling


Why an automatic lubricator instead of manual lubrication
No more manual lubrication
A grease gun depends on people, time and memory. simalube dispenses by itself — continuously, precisely and even where you cannot safely reach with a gun.
- Saves maintenance time and staff
- Greater work safety — fewer interventions on running machines and at heights
- Hard-to-reach points are lubricated permanently
- Lower lubricant consumption
No under- or over-lubrication
Manual lubrication swings between extremes — either too little lubricant (seized bearing) or too much (damaged seal, leakage, dirt). simalube keeps the exact dose throughout the cycle.
- Less wear of components
- Fewer unplanned shutdowns
- Higher machine performance and reliability
Sealed, dustproof and waterproof system
The closed design with IP68 protection rules out mixing up lubricants and dirt entering the lubrication point — it works even under water.
- No mixing up of lubricants
- Lower risk of contamination
- The lubrication point stays clean
Compliance with international standards
The simalube range is certified for demanding and explosive environments and complies with European and British regulations.
- Ex certification (ATEX) in all zones
- Greater workplace safety
- Recycling and disposal according to regulations — no environmental burden
- CE and UKCA compliance


VENTILEK ADVISES:
Five carriages, one lubricator, one replacement a year. But keep the hoses as short as possible and without sharp bends — lubricant in a thin hose does not like unnecessary resistance.
Frequently asked questions
- How many points does the multipoint lubricate?
- Five — each of the five 8 ml chambers has its own outlet and hose.
- Do I have to connect all 5 outlets?
- The multipoint is built for 5 points. If you have fewer, a single-point 15 ml lubricator for each point is more suitable.
- How is the multipoint replaced?
- Snap the empty multipoint off the connector and snap on a new one; the hoses stay connected.
- Which hoses does the multipoint use?
- Ø 4/2.7 mm hoses by the metre, connected with Ø 4 mm quick connectors with G 1/8, G 1/4, M5 or M6 thread.
- Can the multipoint be filled with my own lubricant?
- Yes, it is also available empty (SLM-5X8-00); the SLM-5006 drive unit is used for refilling.
Additional parameters
| Category: | Multipoint automatic lubricators |
|---|---|
| Application: | Empty container |
| Dispenser time: | 1 - 12 months |
| Vessel volume: | 5 x 8 ml |
| Average: | 52 mm |
| Temperature range: | Empty container |
| Height: | 109 mm |
| Thickener: | Empty container |
| Base oil: | Empty container |
| In stock: | External warehouse |
Product rating
Be the first who will post an article to this item!
Simalube is an automatic single-point lubricator made by simatec, a Swiss family company founded in 1983. The lubricator screws straight into the lubrication point and dispenses lubricant on its own, continuously for 1 to 12 months, even where a grease gun cannot reach.
Inside is a dry cell that produces hydrogen: the gas pushes a piston, which presses the lubricant into the bearing. No battery and no cables. The lubricator works in any position, even under water, and the dispensing period can be changed or stopped at any time.
Made in SwitzerlandWhich lubricant for which point
All-purpose SL01, SL24 and SL02
Bearings, guides and standard machines. Multi-purpose grease SL01, EP grease SL24 for changing temperatures and SL02 grease with MoS₂ for shock loads.
- SL01: −30 to +120 °C
- SL24: −30 to +140 °C, outdoor machines
- SL02: shock-loaded bearings and pins
Hot processes SL04 and SL15
Dryers, ovens and paint shops. High-temperature grease SL04 for bearings and synthetic chain oil SL15.
- SL04: grease up to +160 °C
- SL15: chain oil up to +250 °C
- the lubricator itself takes ambient up to +55 °C
Food industry SL10 and SL18
NSF H1 registered lubricants. SL10 grease and SL18 oil for points where incidental food contact is possible.
- SL10: grease −40 to +120 °C
- SL18: oil −15 to +150 °C
- food, beverage and pharmaceutical lines
Chains, gears and outdoors
SL14 oil, SL06 fluid grease and SL09 bio grease. For conveyor chains, central lubrication circuits, gearboxes and machines near water.
- SL14: chain oil −10 to +90 °C
- SL06: fluid EP grease, easy to pump
- SL09: biodegradable grease
Empty SL00 and drive units
For the lubricant your machine maker specifies. Fill the empty lubricator with your own grease or oil. A new drive unit brings a used lubricator back into service.
- all 5 sizes, 15–250 ml
- can be refilled up to three times
- the drive unit must match the size
All simalube lubricators are in one category. The filter narrows them down by lubricant, container size and base oil.
All simalube lubricatorsSimalube fillings side by side
| Type, lubricant, lubricant temperature and use | |||
|---|---|---|---|
| Type | Lubricant | Lubricant temperature | Use |
| SL01 | multi-purpose grease | −30 to +120 °C | rolling and plain bearings, guides, electric motors |
| SL02 | multi-purpose grease with MoS₂ | −25 to +130 °C | shock-loaded bearings, pins, construction machinery |
| SL04 | high-temperature grease | −20 to +160 °C | bearings in dryers, ovens and fans |
| SL06 | fluid EP grease | −30 to +100 °C | central circuits, gearboxes, open gears |
| SL09 | biodegradable grease | −20 to +100 °C | machines near water, forestry and agriculture |
| SL10 | NSF H1 food-grade grease | −40 to +120 °C | food and pharmaceutical lines |
| SL14 | chain oil | −10 to +90 °C | conveyor and drive chains |
| SL15 | high-temperature chain oil | −30 to +250 °C | chains in ovens, paint shops and dryers |
| SL18 | NSF H1 food-grade oil | −15 to +150 °C | food lines, sliding surfaces |
| SL24 | EP grease for a wide temperature range | −30 to +140 °C | construction and mobile machinery, outdoor machines |
| SL00 | empty, for your own lubricant | depends on lubricant | lubricant specified by the machine maker |
The temperature applies to the lubricant; the lubricator itself works at an ambient −20 to +55 °C. Every filling comes in five sizes from 15 to 250 ml.
How to fit the lubricator
1. Choose lubricant and size
Choose the lubricant by location and temperature and the size by consumption. A larger lubricator lasts longer, a smaller one fits into tight spaces.
2. Set the period
Cut off the plastic cap and set the emptying period of 1 to 12 months on the activation screw. Hold an oil lubricator with the thread pointing up.
3. Mark and screw in
Write the activation date on the lubricator with a marker and screw it into the lubrication point. The connection thread is R 1/4″.
4. Replace or refill
Replace an empty lubricator with the same type, or fill it with lubricant and fit a new drive unit of the same size.
Frequently asked questions
- How does a simalube lubricator work?
- Turning the activation screw makes a dry cell produce hydrogen. The gas pushes the piston evenly, which presses the lubricant into the lubrication point. You can see the remaining lubricant through the transparent body.
- How many times can it be refilled?
- Up to three times. Fill the body with lubricant and fit a new drive unit of the same size. The empty SL00 lubricator is filled with your own lubricant from the start.
- Does the lubricator work under water?
- Yes. The lubricator is rated IP68, dust-tight and waterproof, and can be installed in any position. It works at ambient temperatures from −20 to +55 °C.
- Is it suitable for explosive atmospheres?
- Yes. Simalube lubricators are Ex certified for all zones (KEMA 09ATEX0098X, IECEx DEK 20.0032X). The exact marking is on the product page.
- How long can the lubricator be stored?
- It should be activated within 2 years of the production date. Ideally store it at 20 °C ± 5 °C.
Installation and filling instructions and a brochure in Czech are available for download with every lubricator. The manufacturer simatec ag also makes simatherm induction heaters and simatool tools. simalube® is a registered trademark of simatec ag.