CHP high-pressure cyclone separators up to 420 bar

CHP high-pressure cyclone separators remove liquid water, oil and coarse contaminants from compressed air — by centrifugal force, without a filter element. They belong to the range of CHP high-pressure filters: they have the same housing, with a cyclone element instead of a filter element. The housing is made of carbon steel with chemical nickel plating. The condensate drain is ordered separately.
8 sizes from G 1/4" to G 2", flow 667 to 11,917 l/min at 7 bar, working pressure 100, 250 or 420 bar.
Sizes
| CHP high-pressure cyclone separators | |||||||
|---|---|---|---|---|---|---|---|
| Connection | Flow at 7 bar | Separator 100 bar | Separator 250 bar | Separator 420 bar | Spare cyclone element | Dimensions A × B × C × D | Weight |
| G 1/4" | 667 l/min (40 Nm³/h) | CHP1C-003 | CHP2C-003 | CHP4C-003 | CHPC-003V | 182 × 98 × 104 × 30 mm | 7.6 kg |
| G 3/8" | 1,167 l/min (70 Nm³/h) | CHP1C-005 | CHP2C-005 | CHP4C-005 | CHPC-005V | 182 × 98 × 104 × 30 mm | 7.6 kg |
| G 1/2" | 2,167 l/min (130 Nm³/h) | CHP1C-007 | CHP2C-007 | CHP4C-007 | CHPC-007V | 230 × 118 × 129 × 36 mm | 15.3 kg |
| G 3/4" | 3,250 l/min (195 Nm³/h) | CHP1C-010 | CHP2C-010 | CHP4C-010 | CHPC-010V | 254 × 118 × 129 × 36 mm | 16.1 kg |
| G 1" | 4,583 l/min (275 Nm³/h) | CHP1C-018 | CHP2C-018 | CHP4C-018 | CHPC-018V | 276 × 145 × 158 × 46 mm | 26.5 kg |
| G 1 1/4" | 6,333 l/min (380 Nm³/h) | CHP1C-030 | CHP2C-030 | CHP4C-030 | CHPC-030V | 328 × 145 × 158 × 46 mm | 28.6 kg |
| G 1 1/2" | 8,250 l/min (495 Nm³/h) | CHP1C-047 | CHP2C-047 | CHP4C-047 | CHPC-047V | 385 × 195 × 216 × 65 mm | 65.9 kg |
| G 2" | 11,917 l/min (715 Nm³/h) | CHP1C-094 | CHP2C-094 | CHP4C-094 | CHPC-094V | 460 × 195 × 216 × 65 mm | 71.4 kg |
#showmore#
How the separator works
The cyclone element sets the incoming air spinning. Centrifugal force throws the heavier droplets of water and oil and the coarse contaminants against the housing wall, from where they run down to the condensate outlet. The separator has no filter element, so it does not clog like a filter.
Housing and dimensions

The housing is made of carbon steel with chemical nickel plating, the same as on CHP filters. The dimensions and weight apply to all three pressures of the same size.
Flow at a different pressure
The flows apply to a pressure of 7 bar and a temperature of +20 °C. At a different pressure, multiply the flow by the manufacturer’s correction factor:
| Pressure (bar) | 7 | 25 | 40 | 64 | 100 | 250 | 420 |
|---|---|---|---|---|---|---|---|
| Correction factor | 1 | 3 | 5 | 8 | 12 | 12 | 12 |
Condensate drain
The separator comes without a drain. The condensate leaves through a G 1/4" opening in the bottom, which suits timed drains: the TD150M up to 100 bar, and the TD420M-230VAC or TD420M-24VDC for 250 and 420 bar. For other options, see the drains for filters.
Spare cyclone element
A cyclone separator has no filter element, only a cyclone element. The spare cyclone element for each size is in the table above. Separators of the same size for 100, 250 and 420 bar use the same cyclone element.
Where to place it
It goes after the compressor or aftercooler, before the CHP filters. The separator traps most of the liquid water before it reaches the filters, and their elements then last longer.
You will find filters of the same range among the high-pressure filters, and the other separator ranges under cyclone water separators.
Bestsellers
Product sorting
List of products
Spare cyclone element CHPC-018V for the CHP1C-018, CHP2C-018 and CHP4C-018 cyclone separators. The separator has no filter element — the cyclone element is its separating part.
Spare cyclone element CHPC-005V for the CHP1C-005, CHP2C-005 and CHP4C-005 cyclone separators. The separator has no filter element — the cyclone element is its separating part.
Spare cyclone element CHPC-007V for the CHP1C-007, CHP2C-007 and CHP4C-007 cyclone separators. The separator has no filter element — the cyclone element is its separating part.
Spare cyclone element CHPC-010V for the CHP1C-010, CHP2C-010 and CHP4C-010 cyclone separators. The separator has no filter element — the cyclone element is its separating part.
Spare cyclone element CHPC-003V for the CHP1C-003, CHP2C-003 and CHP4C-003 cyclone separators. The separator has no filter element — the cyclone element is its separating part.
Spare cyclone element CHPC-030V for the CHP1C-030, CHP2C-030 and CHP4C-030 cyclone separators. The separator has no filter element — the cyclone element is its separating part.
Spare cyclone element CHPC-047V for the CHP1C-047, CHP2C-047 and CHP4C-047 cyclone separators. The separator has no filter element — the cyclone element is its separating part.
Spare cyclone element CHPC-094V for the CHP1C-094, CHP2C-094 and CHP4C-094 cyclone separators. The separator has no filter element — the cyclone element is its separating part.