Omega Air high-pressure compressed air filters up to 420 bar

CHP and IHP high-pressure filters from the Slovenian manufacturer Omega Air remove solid particles, water, oil aerosol, hydrocarbons and vapours from compressed air at pressures up to 100, 250 or 420 bar. CHP filters have a housing made of chemically nickel-plated carbon steel, IHP filters a stainless steel housing.
Both ranges have 8 sizes with G 1/4" to G 2" threads and flows of 667 to 11,917 l/min at 7 bar. At a higher pressure the filter passes more air — from 100 bar, 12 times as much. The housing holds a single element, and the element determines the filtration stage. The filters are part of the range of industrial compressed air filters.
Choose a range
The range is chosen by the highest pressure in the air line and by the housing material. Each tile leads to a range with all its stages and sizes.

CHP1 filters up to 100 bar
Nickel-plated carbon steel, six stages from a coarse filter to activated carbon.

IHP1 stainless steel filters up to 100 bar
Stainless steel 1.4301, six stages from a stainless steel mesh to activated carbon.

IHP2 stainless steel filters up to 250 bar
The same housing and elements as IHP1, working pressure up to 250 bar.

IHP4 stainless steel filters up to 420 bar
The same housing and elements as IHP1, working pressure up to 420 bar.
Ranges at a glance
| High-pressure filter ranges | ||||
|---|---|---|---|---|
| Range | Housing | Working pressure | Filtration stages | Connection |
| CHP1 filters | nickel-plated carbon steel | 100 bar | B, P, R, M, S, A | G 1/4" to 2" |
| CHP2 filters | nickel-plated carbon steel | 250 bar | B, P, R, M, S, A | G 1/4" to 2" |
| CHP4 filters | nickel-plated carbon steel | 420 bar | B, P, R, M, S, A | G 1/4" to 2" |
| IHP1 filters | stainless steel 1.4301 | 100 bar | N25, N5, R, M, S, A | G 1/4" to 2" |
| IHP2 filters | stainless steel 1.4301 | 250 bar | N25, N5, R, M, S, A | G 1/4" to 2" |
| IHP4 filters | stainless steel 1.4301 | 420 bar | N25, N5, R, M, S, A | G 1/4" to 2" |
Sizes, flows and dimensions are the same for all six ranges; they differ in housing material and working pressure.
Filtration stages
The ISO 8573-1 class is written as solid particles – water – oil. The letter x means that the stage does not determine that component.
| CHP filtration stages | |||||
|---|---|---|---|---|---|
| Stage | Filtration rating | ISO 8573-1 class | Residual oil | Element replacement | Temperature up to |
| B – coarse filter | 15 µm | 8-x-x | – | cleaning, replacement as needed | +65 °C |
| P – basic filter | 3 µm | 6-x-x | – | 350 mbar, at least once a year | +65 °C |
| R – dust filter | 1 µm | 3-x-x | – | 350 mbar, at least once a year | +65 °C |
| M – fine pre-filter | 0.1 µm | 2-x-2 | < 0.1 mg/m³ | 350 mbar, at least once a year | +65 °C |
| S – microfilter | 0.01 µm | 1-x-1 | < 0.01 mg/m³ | 350 mbar, at least once a year | +65 °C |
| A – activated carbon filter | – | 1-x-1 | < 0.005 mg/m³ | every 6 months | +45 °C |
| IHP filtration stages | |||||
|---|---|---|---|---|---|
| Stage | Filtration rating | ISO 8573-1 class | Residual oil | Element replacement | Temperature up to |
| N25 – coarse filter | 25 µm | – | – | at least once a year | +65 °C |
| N5 – basic filter | 5 µm | – | – | at least once a year | +65 °C |
| R – dust filter | 1 µm | 3-x-x | – | 350 mbar, at least once a year | +65 °C |
| M – fine pre-filter | 0.1 µm | 2-x-2 | < 0.1 mg/m³ | 350 mbar, at least once a year | +65 °C |
| S – microfilter | 0.01 µm | 1-x-1 | < 0.01 mg/m³ | 350 mbar, at least once a year | +65 °C |
| A – activated carbon filter | – | 1-x-1 | < 0.005 mg/m³ | every 6 months | +45 °C |
Solid particle class 1 for activated carbon A only applies when an S microfilter is installed before it. The manufacturer does not state a class for the N25 and N5 stainless steel meshes.
#showmore#
How to choose a filter
Pressure first: range 1 is rated up to 100 bar, range 2 up to 250 bar and range 4 up to 420 bar. The working pressure of the range must be equal to or higher than the highest pressure in the air line.
Then the housing material: CHP has a housing made of carbon steel with chemical nickel plating, IHP one made of stainless steel 1.4301, or 1.4404 on request. Sizes, flows and dimensions are the same for both.
Finally, the filtration stage according to how clean the air needs to be, and the size according to the flow at your pressure.
How to put the filtration together

The stages are arranged from coarse to fine in the direction of flow. In the CHP range, this is the coarse filter B, basic P, dust R, fine pre-filter M, microfilter S and finally activated carbon A. In the stainless steel IHP range, filtration starts with the N25 and N5 stainless steel meshes.
The fine pre-filter M goes before the microfilter S and protects its element. An S microfilter always goes before activated carbon — only with it does solid particle class 1 apply. Activated carbon must not work in an oil-saturated environment.
How to read the ISO 8573-1 purity class
The ISO 8573-1 standard describes the purity of compressed air with three numbers: solid particles, water and oil. The lower the number, the cleaner the air.
The S microfilter with class 1-x-1 ensures the highest purity for solid particles and oil, but it does not deal with humidity. Filters only trap water that has already condensed. Water vapour is removed by a compressed air dryer.
Filter sizes

The size determines the thread, the flow and the housing dimensions. All stages of the same size have the same housing; only the element differs.
The smallest filters, 003 and 005, are 182 mm tall; the largest, 094, is 460 mm tall. The CHP housing weighs 7.6 to 71.4 kg, the IHP housing 7.9 to 73.5 kg.
| CHP and IHP filter sizes | |||||||||
|---|---|---|---|---|---|---|---|---|---|
| Size | Thread | Nm³/h at 7 bar | l/min at 7 bar | A | B | C | D | Weight CHP | Weight IHP |
| 003 | G 1/4" | 40 | 667 | 182 mm | 98 mm | 104 mm | 30 mm | 7.6 kg | 7.9 kg |
| 005 | G 3/8" | 70 | 1,167 | 182 mm | 98 mm | 104 mm | 30 mm | 7.6 kg | 7.9 kg |
| 007 | G 1/2" | 130 | 2,167 | 230 mm | 118 mm | 129 mm | 36 mm | 15.3 kg | 15.7 kg |
| 010 | G 3/4" | 195 | 3,250 | 254 mm | 118 mm | 129 mm | 36 mm | 16.1 kg | 16.6 kg |
| 018 | G 1" | 275 | 4,583 | 276 mm | 145 mm | 158 mm | 46 mm | 26.5 kg | 27.3 kg |
| 030 | G 1 1/4" | 380 | 6,333 | 328 mm | 145 mm | 158 mm | 46 mm | 28.6 kg | 29.6 kg |
| 047 | G 1 1/2" | 495 | 8,250 | 385 mm | 195 mm | 216 mm | 65 mm | 65.9 kg | 67.8 kg |
| 094 | G 2" | 715 | 11,917 | 460 mm | 195 mm | 216 mm | 65 mm | 71.4 kg | 73.5 kg |
A height, B head width, C maximum width of the housing, D from the top edge. Dimensions and weights according to the manufacturer.
Flow at a higher pressure

The flows in the tables apply to a pressure of 7 bar and a temperature of +20 °C. At a higher pressure, multiply the flow by the correction factor. The factor rises up to 100 bar and stays at 12 above that.
Example: the CHP1S-007 has a flow of 2,167 l/min at 7 bar and 2,167 × 12 = 26,004 l/min at 100 bar.
| Flow correction factor by pressure | |||||||
|---|---|---|---|---|---|---|---|
| Pressure (bar) | 7 | 25 | 40 | 64 | 100 | 250 | 420 |
| Factor | 1 | 3 | 5 | 8 | 12 | 12 | 12 |
Housing and dimensions

CHP filters: ANSI A-105 carbon steel with chemical nickel plating, fittings and bolts made of stainless steel 1.4404, FKM seals with a PTFE back-up ring. IHP filters: stainless steel 1.4301, 1.4404 on request.
The air is connected through female pipe threads in the filter head; the condensate leaves through a G 1/4" opening in the bottom. The filter is supplied with an element, without a condensate drain.
Accessories
Condensate drainage and mounting
The condensate trapped in the filter has to be drained. For pressures up to 420 bar, the TD420M timed drain for 230 V AC or the TD420M-24VDC for 24 V DC is suitable; it is connected with a G 1/4" thread. You will find more among the TD timed drains.
The filter is fixed to the wall with stainless steel brackets: CHP-WS for sizes 003 and 005, CHP-WM for 007 and 010, CHP-WL for 018 and 030 and CHP-WXL for 047. They fit both CHP and IHP filters.
Liquid water before the filters is separated by CHP cyclone separators and stainless steel IHP cyclone separators.
Where high-pressure filters are used
The manufacturer designs them for general industry, the automotive industry, electronics, food and beverages, chemicals and petrochemicals, plastics and PET production and paint shops. Use with technical gases other than air is assessed separately.
For pressures up to 50 bar, there are HF filters, and for ordinary pressures up to 16 bar, Omega Air industrial filters.
Ventilek’s tip
Choose the range by the highest pressure. The filter must withstand the highest pressure that occurs in the air line. At 300 bar, that means the CHP4 or IHP4 range up to 420 bar, not range 2.
- What is the difference between CHP and IHP?
- The housing material. CHP has a housing made of chemically nickel-plated carbon steel, IHP one made of stainless steel 1.4301, or 1.4404 on request. Pressures, sizes and flows are the same. The IHP range starts filtration with the N25 and N5 stainless steel meshes.
- Which pressure should I choose?
- Range 1 is rated up to 100 bar, range 2 up to 250 bar and range 4 up to 420 bar. The working pressure of the filter must be equal to or higher than the highest pressure in the air line.
- How do I choose the size?
- By the flow at your pressure. The flows in the tables apply to 7 bar; at a higher pressure, multiply them by the correction factor — from 100 bar it is 12.
- How often should the elements be replaced?
- Elements P, R, M and S at a pressure drop of 350 mbar, at least once every 12 months. Activated carbon elements every 6 months. The sintered element B is cleaned in an ultrasonic bath or by blowing it out.
- Does one element fit filters for different pressures?
- Yes. The element fits all three pressure ranges of the same housing and size — for example, the CHPS-007V fits the CHP1S-007, CHP2S-007 and CHP4S-007 filters.
- Is a condensate drain included with the filter?
- No. The filter is supplied with an element; the condensate drain is ordered separately. For pressures up to 420 bar, the TD420M timed drain is suitable.
-
CHP1 filters up to 100 bar
-
CHP2 filters up to 250 bar
-
CHP4 filters up to 420 bar
-
IHP1 stainless steel filters up to 100 bar
-
IHP2 stainless steel filters up to 250 bar
-
IHP4 stainless steel filters up to 420 bar
-
CHP spare elements
-
IHP spare elements