Industrial compressed air filters according to ISO 8573-1

Industrial compressed air filters remove solid contaminants, liquid water, oil, oil vapours and odours from the air after the compressor. The ISO 8573-1 standard describes air purity with three numbers: solid particles, water and oil.
The filters are divided into 10 groups by pressure and application — from Omega Air industrial filters up to 50 bar and high-pressure filters up to 420 bar to process and sterile stainless steel filters. This page is part of compressed air filtration, regulation and treatment.
You can choose by pressure and group or use the calculator. Filters by filtration grade and the selection by ISO class, material and pressure are further down once you expand the description. Looking for a spare element? You will find it in the overview of spare filter elements.
Not sure which filters you need? Based on your application, pressure and flow rate, the calculator puts together the filtration grades, sizes, condensate drains and clogging indication. Without it, the overview of filter groups below will help.
Filters for compressed air lines
The group is chosen by the pressure in the air line and by the environment. Each tile leads to a group with all its ranges, filtration stages and spare elements.

Omega Air industrial filters
AAF and BF ranges up to 16 bar, BFHP up to 25 bar, HF up to 50 bar and AAFHT for hot air up to +120 °C.

High-pressure filters up to 420 bar
CHP ranges in nickel-plated steel and stainless IHP for 100, 250 and 420 bar.

Hankison NGF filters
Five stages from a basic filter to activated carbon, up to 16 bar, with clogging indication.

Stainless steel process filters
Stainless steel 1.4404 up to 14 and 50 bar for the food, pharmaceutical and chemical industries.
Filters for special applications

Sterile stainless steel filters
0.01 µm sterile element for pharmaceuticals and food, air venting filters for tanks.

PPA filtration system
Wall-mounted unit for painting: filtration, activated carbon, regulator and 2 quick couplings.
What air quality do you need – ISO 8573-1
ISO 8573-1 describes compressed air purity with three numbers in the order solid particles : water : oil. The lower the number, the cleaner the air – class 1 is the strictest. Filters remove solid particles and oil; the dryer determines the water class.
| Examples of ISO 8573-1 classes by application | ||||
|---|---|---|---|---|
| Application | ISO 8573-1 class | Water – pressure dew point | Total oil | Set-up in the direction of flow |
| Workshop, tools, air line | 3:4:4 | +3 °C | up to 5 mg/m³ | Basic filter → refrigeration dryer → dust filter |
| Spray painting | 1:4:1 | +3 °C | up to 0.01 mg/m³ | Basic filter → refrigeration dryer → fine pre-filter → microfilter → activated carbon; silicone-free |
| Food – direct contact | 1:2:1 | −40 °C | up to 0.01 mg/m³ | Basic filter → fine pre-filter → desiccant dryer → microfilter → activated carbon |
| Food – indirect contact | 2:4:2 | +3 °C | up to 0.1 mg/m³ | Basic filter → refrigeration dryer → fine pre-filter |
| Instrument air | 1:4:1 | +3 °C | up to 0.01 mg/m³ | Basic filter → refrigeration dryer → fine pre-filter → microfilter |
| Laser cutting | 1:4:1 | +3 °C | up to 0.01 mg/m³ | Basic filter → refrigeration dryer → fine pre-filter → microfilter → activated carbon |
| Pharmaceuticals, cleanrooms | 1:2:1 | −40 °C | up to 0.01 mg/m³ | Basic filter → fine pre-filter → desiccant dryer → microfilter → activated carbon; sterile filter at the point of use, stainless steel design |
The calculator above works out the set-up for your pressure and flow rate, including sizes. A detailed table of classes and filtration grades is further down once you expand the description.
#showmore#
Filters by filtration grade
In the direction of air flow, from coarse to finest – each grade protects the next. Each grade page lists the filters of all series, their spare elements and the filters of air treatment units.
Selection by ISO class, material and pressure
| Filters of all series by one property | |
|---|---|
| By | Pages |
| Material and connection | stainless steel filters · flanged filters DN10–DN300 |
| Solid particle class ISO 8573-1 | class 1 · class 2 · class 3 · class 6 · class 7 |
| Oil class ISO 8573-1 | class 1 · class 2 · class 4 |
| Housing pressure | 10 bar · 11 bar · 16 bar · 50 bar · 100 bar · 250 bar |
| Condensate drain | automatic · manual · without drain |
Which group for your pressure

Standard air lines up to 16 bar are covered by AAF filters and Hankison NGF; for large flows there are BF flanged filters, and for pressures up to 25 bar BFHP. Up to 50 bar there are HF high-pressure filters, for 100 to 420 bar the CHP and IHP ranges.
Hot air after the compressor up to +120 °C is handled by AAFHT filters for high temperatures. Where the air comes into contact with food or pharmaceuticals, stainless steel process and sterile filters are used.
Groups at a glance
| Industrial filter groups and ranges | ||
|---|---|---|
| Group and range | Working pressure | Application |
| Omega Air AAF filters | up to 16 bar | compressed air lines |
| AAFHT filters for high temperatures | up to 13 bar | hot air up to +120 °C |
| BF flanged filters | up to 16 bar | large flows, DN80 to DN300 flanges |
| BFHP flanged filters | up to 25 bar | large flows at higher pressure |
| HF high-pressure filters | up to 50 bar | air lines above 16 bar |
| CHP and IHP high-pressure filters | 100, 250 and 420 bar | high-pressure air lines |
| Hankison NGF filters | up to 16 bar | air lines with clogging indication |
| PF, HPF, WFIT, WFIF, WFIW and WHFIT process filters | up to 14 and 50 bar | food, pharmaceuticals, chemicals |
| SF and SPF sterile filters, AV and AVI air venting filters | up to 10 and 14 bar | sterile air, tank venting |
| AAFS silicone-free filters | up to 16 bar | paint shops, surface finishing |
| PPA filtration system | up to 16 bar | painting |
| B-AIR and B-AIR PLUS breathing air | up to 16 bar | air for breathing |
| AAFO2 and HFO2 oxygen filters | up to 16 and 50 bar | compressed oxygen |
| P-VAC and M-VAC vacuum filters | 20 to 2,000 mbar absolute | vacuum pumps |
Working pressure according to the manufacturers’ technical data sheets. Detailed sizes, flows and connections are on the group pages.
Filtration stages and ISO 8573-1 classes
In most ranges, the letter after the range name determines the filtration stage. The ISO 8573-1 class is written as solid particles – water – oil; filters selected by solid particle class are in the last column.
| Omega Air filtration stages | ||||
|---|---|---|---|---|
| Stage | Filtration rating | ISO 8573-1 class | Residual oil | Filters by class |
| coarse filter B | 15 µm | 7-x-x | – | class 7 |
| basic filter P | 3 µm | 6-x-x | – | class 6 |
| dust filter R | 1 µm | 3-x-x | – | class 3 |
| fine pre-filter M | 0.1 µm | 2-x-2 | < 0.1 mg/m³ | class 2 |
| microfilter S | 0.01 µm | 1-x-1 | < 0.01 mg/m³ | class 1 |
| activated carbon A | – | 1-x-1 | < 0.005 mg/m³ | – |
Solid particle class 1 for activated carbon A only applies when an S microfilter is installed before it. Values according to the Omega Air technical data sheets.
How to put the filtration together

The filters are arranged one after another from coarse to fine in the direction of flow. Each coarser stage protects the finer element after it from clogging.
The fine pre-filter M goes before the microfilter S, and an S microfilter always goes before activated carbon — activated carbon must not work in an oil-saturated environment. Liquid water directly after the compressor is separated by the AAFC or HFC cyclone separator.
How to read the ISO 8573-1 purity class
The ISO 8573-1 standard describes the purity of compressed air with three numbers: solid particles, water and oil. The lower the number, the cleaner the air. The letter x means that the filter does not determine that component.
Filters only trap water that has already condensed. Water vapour, and therefore the water class, is determined by a compressed air dryer.
Condensate drainage
A drain releases the condensate from the filter bowl. You will find filters with automatic drain, with manual drain and without a drain.
An automatic drain releases the condensate by itself; a manual drain has to be opened regularly. Filters without a drain are fitted with a suitable type from the condensate drains according to the pressure.
What goes with the filters
Ventilek’s tip
Choose the group by the pressure in the air line and the filter size by the flow at the actual pressure. The flows in the tables apply to 7 bar — at a lower pressure the filter passes less air, at a higher pressure more. An undersized filter has a high pressure drop and its element clogs faster.
- How do I choose the filter size?
- By the flow at your pressure. The flows in the tables apply to 7 bar; at a different pressure, they are multiplied by a pressure-dependent correction factor.
- What does class 1-x-1 mean?
- The first number is the solid particle class, the second the water class and the third the oil class. The letter x means that the filter does not determine that component — water vapour is removed by a dryer.
- Which group should I choose for pressures above 16 bar?
- Up to 25 bar the BFHP flanged filters, up to 50 bar the HF range, and for 100 to 420 bar the CHP and IHP high-pressure filters.
- In what order are the filters arranged?
- From coarse to fine: coarse filter B, basic P, dust R, fine pre-filter M, microfilter S and finally activated carbon A.
- Does the filter remove moisture from the air?
- Only liquid water that has already condensed. Water vapour is removed by a compressed air dryer.
- When should I use a stainless steel filter?
- When the air comes into contact with food, pharmaceuticals or chemicals. Process and sterile filters have a housing made of stainless steel 1.4404.
Product sorting
List of products
The MDM40 magnetic differential pressure gauge fits on the filter head and shows the pressure drop across the element on a scale with a green and a red field. Up to 16 bar.
Spare element AAFM-120V for fine pre-filter AAFM-120. Recommended replacement every 12 months or 4,000 operating hours.
The PDI mechanical indicator fits on the filter head and shows by colour whether the element is clean (green) or clogged (red). Working pressure up to 16 bar.
Spare element AAFP-1000V for basic filter AAFP-1000. Recommended replacement every 12 months or 4,000 operating hours.
Spare element AAFM-35V for fine pre-filters AAFM-35 and AAFM-60. Recommended replacement every 12 months or 4,000 operating hours.
Spare element AAFS-78V for microfilter AAFS-78. Recommended replacement every 12 months or 4,000 operating hours.
The stainless steel AF-WM kit fixes an Omega Air AF series filter, sizes AF-33 to AF-130, to the wall. It carries up to 15 kg.
Spare cyclone element AAFC-78V for the AAFC-78 cyclone separator. Recommended replacement every 12 months or 4,000 operating hours.
Spare cyclone element AAFC-1000V for the AAFC-1000 cyclone separator. Recommended replacement every 12 months or 4,000 operating hours.
The AF-2M connection kit joins 2 Omega Air AF series filters, sizes AF-33 to AF-130, into one bank.
The stainless steel AF-WS kit fixes an Omega Air AF series filter, sizes AF-10 to AF-20, to the wall. It carries up to 6 kg.
Parts for joining the filters and 2 brackets for wall mounting, for 3 AAF filters, sizes 35 to 120.
The AF-3M connection kit joins 3 Omega Air AF series filters, sizes AF-33 to AF-130, into one bank.
Spare cyclone element AAFC-198V for the AAFC-198 cyclone separator. Recommended replacement every 12 months or 4,000 operating hours.
Spare cyclone element AAFC-120V for the AAFC-120 cyclone separator. Recommended replacement every 12 months or 4,000 operating hours.
Spare cyclone element AAFC-510V for the AAFC-510 cyclone separator. Recommended replacement every 12 months or 4,000 operating hours.
With a G 3/8" thread and a flow of 983 l/min, the Hankison NGF F03-B-HF microfilter traps solid and liquid particles larger than 0.01 µm and removes over 99.9% of oil aerosol;...
With a G 3" thread and a flow of 36,000 l/min at 7 bar, the AAFC-2160 cyclone separator removes liquid water directly after the compressor. Working pressure up to 16 bar.
Spare element AAFS-120V for microfilter AAFS-120. Recommended replacement every 12 months or 4,000 operating hours.
Spare element SF-04 with a orange end cap for the Hankison F04-B-SF basic filter. Replacement: 6,000 h / 12 months.
Spare element HF-03 with a green end cap for the Hankison F03-B-HF microfilter. Replacement: 3,000 h / 12 months.
The AK-12 connection kit joins filters with a 1/2" thread into one bank, and its bracket fixes the bank to the wall. Up to 20 bar.
Spare element AAFS-335V for microfilter AAFS-335. Recommended replacement every 12 months or 4,000 operating hours.
Spare element AAFP-510V for basic filter AAFP-510. Recommended replacement every 12 months or 4,000 operating hours.
The AK-38 connection kit joins filters with a 3/8" thread into one bank, and its bracket fixes the bank to the wall. Up to 20 bar.
Omega Air AFM-170 fine pre-filter with a 2" thread and a flow of 16,667 l/min at 7 bar, up to 16 bar. The AF series has been replaced by the AAF series; the successor is the...
The AK-34 connection kit joins filters with a 3/4" thread into one bank, and its bracket fixes the bank to the wall. Up to 20 bar.
With a G 1/2" thread and a flow of 1,300 l/min at 7 bar, the AAFC-78 cyclone separator removes liquid water directly after the compressor. Working pressure up to 16 bar.
Parts for joining the filters into one bank through the holes in the head, for 3 AAF filters, sizes 35 to 120.
Manual condensate drain MCD in brass with a G 1/2" thread for filters, pressure vessels and cyclone separators. It opens with a turn. Up to 20 bar.
Omega Air AFM-33 fine pre-filter with a 1" thread and a flow of 3,300 l/min at 7 bar, up to 16 bar. The AF series has been replaced by the AAF series; the successor is the...
2 brackets and parts for wall mounting one AAF filter, sizes 35 to 120.
The MDHI 50 differential pressure gauge shows the pressure drop of the filter element on HF filters with pressures up to 50 bar. Range 0 to 1 bar, 2 × G 1/8" connection,...
Parts for joining the filters into one bank through the holes in the head, for 2 AAF filters, sizes 35 to 120.
The AK-15 connection kit joins filters with a 1 1/2" thread into one bank, and its bracket fixes the bank to the wall. Up to 20 bar.
Spare element AAFA-78V for activated carbon filter AAFA-78. Recommended replacement within 6 months at the latest, earlier if the oil content is higher.
Parts for joining the filters into one bank through the holes in the head, for 2 AAF filters, sizes 198 to 780.
Parts for joining the filters into one bank through the holes in the head, for 3 AAF filters, sizes 198 to 780.
Omega Air AFS-170 microfilter with a 2" thread and a flow of 16,667 l/min at 7 bar, up to 16 bar. The AF series has been replaced by the AAF series; the successor is the AAFS-1000.
Omega Air AFR-33 dust filter with a 1" thread and a flow of 3,300 l/min at 7 bar, up to 16 bar. The AF series has been replaced by the AAF series; the successor is the AAFR-198.