Omega Air industrial compressed air filters up to 50 bar

Omega Air industrial filters from the Slovenian manufacturer remove solid contaminants, water, oil, oil vapours and odours from compressed air. The filter housing holds an element, and the element determines the filtration stage — from a 15 µm coarse filter to activated carbon.
There are five ranges to choose from: AAF and BF up to 16 bar, BFHP up to 25 bar, HF up to 50 bar and AAFHT for hot air up to +120 °C. The connection is a G 1/8" to 3" thread or DN80 to DN300 flanges, with flows of 167 to 523,333 l/min at 7 bar. All five ranges are among the industrial compressed air filters.
Choose a range
The range is chosen by pressure, flow and air temperature. Each tile leads to a range with all its filtration stages, sizes and spare elements.

AAFHT filters for high temperatures
Up to +120 °C at 10 bar and +85 °C at 13 bar, G 1/8" to 3" thread, 17 sizes.

BFHP flanged filters up to 25 bar
Steel housing with DN80 to DN300 flanges for higher pressure, 10 sizes.

HF high-pressure filters up to 50 bar
Aluminium housing for higher pressure, G 1/2" to 3" thread, 9 sizes.
Which range for your pressure and flow

Up to 16 bar and a flow of up to 46,000 l/min, choose the AAF range. For larger flows of up to 523,333 l/min, there is the BF flanged range, which holds 1 to 20 identical elements. For pressures up to 25 bar, there are BFHP flanged filters in the same sizes.
At pressures above 16 bar and flows of up to 46,000 l/min, the HF range up to 50 bar belongs in the air line. For hot air up to +120 °C, there are AAFHT filters. For pressures of 100 to 420 bar, there are CHP and IHP high-pressure filters.
Ranges at a glance
| Omega Air filter ranges | ||||||
|---|---|---|---|---|---|---|
| Range | Working pressure | Connection | Sizes | Flow at 7 bar | Housing | Element stages |
| AAF | up to 16 bar | G 1/4" to 3" thread | 15 | 417 to 46,000 l/min | aluminium | 9 + cyclone separator |
| AAFHT | up to 13 bar (+120 °C up to 10 bar) | G 1/8" to 3" thread | 17 | 167 to 46,000 l/min | aluminium | 6 + cyclone separator |
| BF | up to 16 bar | DN80 to DN300 flanges | 10 | 28,000 to 523,333 l/min | welded carbon steel | 6 |
| BFHP | up to 25 bar | DN80 to DN300 flanges | 10 | 28,000 to 523,333 l/min | carbon steel | 6 |
| HF | up to 50 bar | G 1/2" to 3" thread | 9 | 1,183 to 46,000 l/min | cast aluminium | 6 + cyclone separator |
Working pressure, connection and flows according to the manufacturer’s technical data sheets. The flow applies to a pressure of 7 bar and a temperature of +20 °C.
Filtration stages
The stage codes are the same in all ranges: the letter after the range name determines the element. The ISO 8573-1 class is written as solid particles – water – oil.
| Filtration stages in the AAF, BF, BFHP and HF ranges | |||||||
|---|---|---|---|---|---|---|---|
| Stage | Filtration rating | ISO 8573-1 class | Residual oil | AAF | BF | BFHP | HF |
| cyclone separator | – | – | – | AAFC | – | – | HFC |
| coarse filter B | 15 µm | 7-x-x | – | AAFB | BFB | BFHPB | HFB |
| basic filter P | 3 µm | 6-x-x | – | AAFP | BFP | BFHPP | HFP |
| dust filter R | 1 µm | 3-x-x | – | AAFR | BFR | BFHPR | HFR |
| fine pre-filter M | 0.1 µm | 2-x-2 | < 0.1 mg/m³ | AAFM | BFM | BFHPM | HFM |
| microfilter S | 0.01 µm | 1-x-1 | < 0.01 mg/m³ | AAFS | BFS | BFHPS | HFS |
| activated carbon A | – | 1-x-1 | < 0.005 mg/m³ | AAFA | BFA | BFHPA | HFA |
| adsorption filter A2 | – | 1-x-0 | < 0.005 mg/m³ | AAFA2 | – | – | – |
| catalytic filter (reduces CO) H2 | – | 1-x-x | < 0.005 mg/m³ | AAFH2 | – | – | – |
| molecular sieve MS2 | – | 1-x-x | – | AAFMS2 | – | – | – |
Solid particle class 1 for activated carbon A only applies when an S microfilter is installed before it. Stages B to S withstand +65 °C, stages A, A2, H2 and MS2 +45 °C. The AAFHT range for high temperatures has its own stages: cyclone separator C, coarse filter B, meshes N25 and N5, dust filter R, fine pre-filter M and microfilter S.
#showmore#
How to put the filtration together

The filters are arranged one after another from coarse to fine in the direction of flow: coarse filter B, basic filter P, dust filter R, fine pre-filter M, microfilter S and finally activated carbon A. Each coarser stage protects the finer element after it from clogging.
The fine pre-filter M goes before the microfilter S. An S microfilter always goes before activated carbon — activated carbon must not work in an oil-saturated environment. Liquid water directly after the compressor is separated by the AAFC or HFC cyclone separator.
How to read the ISO 8573-1 purity class
The ISO 8573-1 standard describes the purity of compressed air with three numbers: solid particles, water and oil. The lower the number, the cleaner the air. The letter x means that the filter does not determine that component.
The S microfilter with class 1-x-1 ensures the highest purity for solid particles and oil, but it does not deal with humidity. Filters only trap water that has already condensed. Water vapour is removed by a compressed air dryer.
Flow at a different pressure

The flows in the tables apply to a pressure of 7 bar. At a different pressure, multiply the flow by the correction factor: at 4 bar it is 0.63, at 16 bar 2.13 and at 50 bar 6.38.
Example: a filter with a flow of 2,000 l/min at 7 bar passes 2,000 × 2.13 = 4,260 l/min at 16 bar. So choose the filter size by the flow at your actual pressure.
Accessories for the filters
Element replacement
Elements of stages B to S are replaced at least once a year or at a pressure drop of 350 mbar, activated carbon elements within 6 months at the latest.
AAF filters have a factory-fitted drain in the bowl: the AOK16B float drain, or the MCD manual drain for stages A, A2, H2 and MS2. BF, BFHP and HF filters are supplied without a condensate drain — you will find suitable drains among the condensate drains.
Other Omega Air filters

Stainless steel process filters
Stainless steel 1.4404 housings up to 14 and 50 bar for the food and chemical industries.
Ventilek’s tip
Choose the filter size by the flow at the actual pressure. The flows in the tables apply to 7 bar — at a lower pressure the filter passes less air, at a higher pressure more. An undersized filter has a high pressure drop and its element clogs faster.
- What is the difference between the AAF, BF and HF ranges?
- AAF and BF work up to 16 bar, HF up to 50 bar. AAF and HF have an aluminium housing with a thread, BF a welded steel housing with flanges for large flows.
- What are the AAFHT and BFHP ranges for?
- AAFHT is for hot air: up to +120 °C at 10 bar and up to +85 °C at 13 bar. BFHP has the same flanges and flows as BF, but works up to 25 bar.
- Which range should I choose for pressures above 16 bar?
- For large flows up to 25 bar, the BFHP flanged filters; with a thread up to 50 bar, the HF range. For pressures of 100 to 420 bar, there are CHP and IHP high-pressure filters.
- How do I choose the filter size?
- By the flow at your pressure. The flows in the tables apply to 7 bar; at a different pressure, multiply them by the correction factor.
- How often should the elements be replaced?
- Elements B to S at least once a year or at a pressure drop of 350 mbar, activated carbon elements every 6 months.
- Does the filter remove moisture from the air?
- Only liquid water that has already condensed. Water vapour is removed by a compressed air dryer.
- Is a condensate drain included with the filter?
- For the AAF range, yes: the AOK16B float drain; the activated carbon stages and the other adsorption stages have the MCD manual drain. BF, BFHP and HF filters are supplied without a condensate drain; the drain is chosen separately according to the pressure.
Product sorting
List of products
The MDM40 magnetic differential pressure gauge fits on the filter head and shows the pressure drop across the element on a scale with a green and a red field. Up to 16 bar.
Spare element AAFM-120V for fine pre-filter AAFM-120. Recommended replacement every 12 months or 4,000 operating hours.
The PDI mechanical indicator fits on the filter head and shows by colour whether the element is clean (green) or clogged (red). Working pressure up to 16 bar.
The AOK16B float drain releases condensate automatically, with no electricity and no setting up. It is fitted inside the filter bowl. Up to 16 bar, 120 l/h at 7 bar.
Spare element AAFP-1000V for basic filter AAFP-1000. Recommended replacement every 12 months or 4,000 operating hours.
Spare element AAFM-35V for fine pre-filters AAFM-35 and AAFM-60. Recommended replacement every 12 months or 4,000 operating hours.
Spare element AAFS-78V for microfilter AAFS-78. Recommended replacement every 12 months or 4,000 operating hours.
The stainless steel AF-WM kit fixes an Omega Air AF series filter, sizes AF-33 to AF-130, to the wall. It carries up to 15 kg.
Spare cyclone element AAFC-1000V for the AAFC-1000 cyclone separator. Recommended replacement every 12 months or 4,000 operating hours.
The AF-2M connection kit joins 2 Omega Air AF series filters, sizes AF-33 to AF-130, into one bank.
The stainless steel AF-WS kit fixes an Omega Air AF series filter, sizes AF-10 to AF-20, to the wall. It carries up to 6 kg.
The AF-3M connection kit joins 3 Omega Air AF series filters, sizes AF-33 to AF-130, into one bank.
Spare cyclone element AAFC-198V for the AAFC-198 cyclone separator. Recommended replacement every 12 months or 4,000 operating hours.
Spare cyclone element AAFC-120V for the AAFC-120 cyclone separator. Recommended replacement every 12 months or 4,000 operating hours.
Spare cyclone element AAFC-510V for the AAFC-510 cyclone separator. Recommended replacement every 12 months or 4,000 operating hours.
With a G 3" thread and a flow of 36,000 l/min at 7 bar, the AAFC-2160 cyclone separator removes liquid water directly after the compressor. Working pressure up to 16 bar.
Spare element AAFS-120V for microfilter AAFS-120. Recommended replacement every 12 months or 4,000 operating hours.
The AK-12 connection kit joins filters with a 1/2" thread into one bank, and its bracket fixes the bank to the wall. Up to 20 bar.
Spare element AAFS-335V for microfilter AAFS-335. Recommended replacement every 12 months or 4,000 operating hours.
Spare element AAFP-510V for basic filter AAFP-510. Recommended replacement every 12 months or 4,000 operating hours.
The AK-38 connection kit joins filters with a 3/8" thread into one bank, and its bracket fixes the bank to the wall. Up to 20 bar.
Omega Air AFM-170 fine pre-filter with a 2" thread and a flow of 16,667 l/min at 7 bar, up to 16 bar. The AF series has been replaced by the AAF series; the successor is the...
The AK-34 connection kit joins filters with a 3/4" thread into one bank, and its bracket fixes the bank to the wall. Up to 20 bar.
With a G 1 1/2" thread and a flow of 8,500 l/min at 7 bar, the AAFC-510 cyclone separator removes liquid water directly after the compressor. Working pressure up to 16 bar.
With a G 1/2" thread and a flow of 1,300 l/min at 7 bar, the AAFC-78 cyclone separator removes liquid water directly after the compressor. Working pressure up to 16 bar.
Manual condensate drain MCD in brass with a G 1/2" thread for filters, pressure vessels and cyclone separators. It opens with a turn. Up to 20 bar.
Omega Air AFM-33 fine pre-filter with a 1" thread and a flow of 3,300 l/min at 7 bar, up to 16 bar. The AF series has been replaced by the AAF series; the successor is the...
The MDHI 50 differential pressure gauge shows the pressure drop of the filter element on HF filters with pressures up to 50 bar. Range 0 to 1 bar, 2 × G 1/8" connection,...
The AK-15 connection kit joins filters with a 1 1/2" thread into one bank, and its bracket fixes the bank to the wall. Up to 20 bar.
Spare element AAFA-78V for activated carbon filter AAFA-78. Recommended replacement within 6 months at the latest, earlier if the oil content is higher.
Omega Air AFS-170 microfilter with a 2" thread and a flow of 16,667 l/min at 7 bar, up to 16 bar. The AF series has been replaced by the AAF series; the successor is the AAFS-1000.
Omega Air AFR-33 dust filter with a 1" thread and a flow of 3,300 l/min at 7 bar, up to 16 bar. The AF series has been replaced by the AAF series; the successor is the AAFR-198.
Spare element AAFMS2-120V for molecular sieve filter AAFMS2-120. Recommended replacement within 6 months at the latest, earlier depending on use.
With a G 2" thread and a flow of 16,667 l/min at 7 bar, the AAFC-1000 cyclone separator removes liquid water directly after the compressor. Working pressure up to 16 bar.
With a G 2" thread and a flow of 25,000 l/min at 7 bar, the AAFC-1500 cyclone separator removes liquid water directly after the compressor. Working pressure up to 16 bar.
Omega Air AFP-33 basic filter with a 1" thread and a flow of 3,300 l/min at 7 bar, up to 16 bar. The AF series has been replaced by the AAF series; the successor is the AAFP-198.
With a G 1 1/2" thread and a flow of 8,500 l/min at 7 bar, the AAFM-510 fine pre-filter traps fine solid particles larger than 0.1 µm, water and oil; residual oil is below 0.1...
The AOK13PA float drain releases condensate automatically, with no electricity and no setting up. It is fitted to the outside of the filter bowl. Up to 13 bar, 167 l/h at 7 bar.
Spare element AAFP-25V for basic filters AAFP-25 and AAFP-30. Recommended replacement every 12 months or 4,000 operating hours.
Spare cyclone element AAFC-60V for the AAFC-60 cyclone separator. Recommended replacement every 12 months or 4,000 operating hours.