AAFHTN5 mesh pre-filters for high temperatures

AAFHTN5 mesh pre-filters for high temperatures trap solid contaminants larger than 5 µm. They belong to the range of Omega Air AAFHT filters for high temperatures: they work up to 13 bar at +85 °C, or up to 10 bar at +120 °C.
17 sizes from 1/8" to 3", flow of 167 to 46,000 l/min at 7 bar. Supplied as a filter housing with an element and an MCD manual condensate drain.
Sizes
| Filter | Connection | Flow at 7 bar | Dimensions A × B × C × D | Spare element |
|---|---|---|---|---|
| AAFHTN5-10 | 1/8" | 167 l/min | 105 × 55 × 14 × 50 mm | AAFHTN5-10V |
| AAFHTN5-18 | 1/4" | 300 l/min | 125 × 55 × 14 × 70 mm | AAFHTN5-18V |
| AAFHTN5-25 | 1/4" | 417 l/min | 145 × 73 × 18 × 50 mm | AAFHTN5-25V |
| AAFHTN5-30 | 3/8" | 500 l/min | 145 × 73 × 18 × 50 mm | |
| AAFHTN5-35 | 1/4" | 583 l/min | 189 × 88 × 21 × 60 mm | AAFHTN5-35V |
| AAFHTN5-60 | 3/8" | 1,000 l/min | 189 × 88 × 21 × 60 mm | |
| AAFHTN5-78 | 1/2" | 1,300 l/min | 189 × 88 × 21 × 80 mm | AAFHTN5-78V |
| AAFHTN5-120 | 3/4" | 2,000 l/min | 257 × 88 × 21 × 150 mm | AAFHTN5-120V |
| AAFHTN5-198 | 1" | 3,300 l/min | 261 × 125 × 37 × 160 mm | AAFHTN5-198V |
| AAFHTN5-335 | 1" | 5,583 l/min | 361 × 125 × 37 × 250 mm | AAFHTN5-335V |
| AAFHTN5-510 | 1 1/2" | 8,500 l/min | 461 × 125 × 37 × 350 mm | AAFHTN5-510V |
| AAFHTN5-780 | 1 1/2" | 13,000 l/min | 641 × 125 × 37 × 530 mm | AAFHTN5-780V |
| AAFHTN5-1000 | 2" | 16,667 l/min | 696 × 164 × 50 × 520 mm | AAFHTN5-1000V |
| AAFHTN5-1500 | 2" | 25,000 l/min | 943 × 164 × 50 × 770 mm | AAFHTN5-1500V |
| AAFHTN5-1680 | 2 1/2" | 28,000 l/min | 943 × 164 × 50 × 770 mm | |
| AAFHTN5-2160 | 3" | 36,000 l/min | 801 × 242 × 60 × 630 mm | AAFHTN5-2160V |
| AAFHTN5-2760 | 3" | 46,000 l/min | 998 × 242 × 60 × 780 mm | AAFHTN5-2760V |
#showmore#
Where to place it

It goes before the AAFHTR dust filter and the AAFHTM fine pre-filter. It can be preceded by the coarser N25 mesh pre-filter.
Element replacement
Replace the element once every 12 months, or earlier when the pressure drop across the filter reaches 350 mbar. Elements for all stages are among the AAFHT spare elements.
Flow at a different pressure
The flows in the tables apply to a pressure of 7 bar and a temperature of +20 °C. At a different pressure, multiply the flow by the manufacturer’s correction factor:
| Pressure (bar) | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Correction factor | 0.38 | 0.5 | 0.63 | 0.75 | 0.88 | 1 | 1.13 | 1.25 | 1.38 | 1.5 | 1.63 | 1.75 |
Above 10 bar, the maximum working temperature is +85 °C. For other conditions, such as a different temperature, the flow has to be recalculated — contact us.
You will find other Omega Air filters among the Omega Air industrial compressed air filters.
Product sorting
List of products
The AAFHTN5-10 high-temperature mesh pre-filter traps solid contaminants larger than 5 µm. It has a 1/8" female thread and a flow of 167 l/min at 7 bar; it works up to 13 bar at...
The AAFHTN5-1000 high-temperature mesh pre-filter traps solid contaminants larger than 5 µm. It has a 2" female thread and a flow of 16,667 l/min at 7 bar; it works up to 13 bar...
The AAFHTN5-120 high-temperature mesh pre-filter traps solid contaminants larger than 5 µm. It has a 3/4" female thread and a flow of 2,000 l/min at 7 bar; it works up to 13 bar...
The AAFHTN5-1500 high-temperature mesh pre-filter traps solid contaminants larger than 5 µm. It has a 2" female thread and a flow of 25,000 l/min at 7 bar; it works up to 13 bar...
The AAFHTN5-1680 high-temperature mesh pre-filter traps solid contaminants larger than 5 µm. It has a 2 1/2" female thread and a flow of 28,000 l/min at 7 bar; it works up to 13...
The AAFHTN5-18 high-temperature mesh pre-filter traps solid contaminants larger than 5 µm. It has a 1/4" female thread and a flow of 300 l/min at 7 bar; it works up to 13 bar at...
The AAFHTN5-198 high-temperature mesh pre-filter traps solid contaminants larger than 5 µm. It has a 1" female thread and a flow of 3,300 l/min at 7 bar; it works up to 13 bar...
The AAFHTN5-2160 high-temperature mesh pre-filter traps solid contaminants larger than 5 µm. It has a 3" female thread and a flow of 36,000 l/min at 7 bar; it works up to 13 bar...
The AAFHTN5-25 high-temperature mesh pre-filter traps solid contaminants larger than 5 µm. It has a 1/4" female thread and a flow of 417 l/min at 7 bar; it works up to 13 bar at...
The AAFHTN5-2760 high-temperature mesh pre-filter traps solid contaminants larger than 5 µm. It has a 3" female thread and a flow of 46,000 l/min at 7 bar; it works up to 13 bar...
The AAFHTN5-30 high-temperature mesh pre-filter traps solid contaminants larger than 5 µm. It has a 3/8" female thread and a flow of 500 l/min at 7 bar; it works up to 13 bar at...
The AAFHTN5-335 high-temperature mesh pre-filter traps solid contaminants larger than 5 µm. It has a 1" female thread and a flow of 5,583 l/min at 7 bar; it works up to 13 bar...
The AAFHTN5-35 high-temperature mesh pre-filter traps solid contaminants larger than 5 µm. It has a 1/4" female thread and a flow of 583 l/min at 7 bar; it works up to 13 bar at...
The AAFHTN5-510 high-temperature mesh pre-filter traps solid contaminants larger than 5 µm. It has a 1 1/2" female thread and a flow of 8,500 l/min at 7 bar; it works up to 13...
The AAFHTN5-60 high-temperature mesh pre-filter traps solid contaminants larger than 5 µm. It has a 3/8" female thread and a flow of 1,000 l/min at 7 bar; it works up to 13 bar...
The AAFHTN5-78 high-temperature mesh pre-filter traps solid contaminants larger than 5 µm. It has a 1/2" female thread and a flow of 1,300 l/min at 7 bar; it works up to 13 bar...
The AAFHTN5-780 high-temperature mesh pre-filter traps solid contaminants larger than 5 µm. It has a 1 1/2" female thread and a flow of 13,000 l/min at 7 bar; it works up to 13...
Spare element AAFHTN5-1000V for the AAFHTN5-1000 mesh pre-filter. Replace it once every 12 months, or earlier at a pressure drop of 350 mbar.
Spare element AAFHTN5-10V for the AAFHTN5-10 mesh pre-filter. Replace it once every 12 months, or earlier at a pressure drop of 350 mbar.
Spare element AAFHTN5-120V for the AAFHTN5-120 mesh pre-filter. Replace it once every 12 months, or earlier at a pressure drop of 350 mbar.
Spare element AAFHTN5-1500V for the AAFHTN5-1500 and AAFHTN5-1680 mesh pre-filters. Replace it once every 12 months, or earlier at a pressure drop of 350 mbar.
Spare element AAFHTN5-18V for the AAFHTN5-18 mesh pre-filter. Replace it once every 12 months, or earlier at a pressure drop of 350 mbar.
Spare element AAFHTN5-198V for the AAFHTN5-198 mesh pre-filter. Replace it once every 12 months, or earlier at a pressure drop of 350 mbar.
Spare element AAFHTN5-2160V for the AAFHTN5-2160 mesh pre-filter. Replace it once every 12 months, or earlier at a pressure drop of 350 mbar.
Spare element AAFHTN5-25V for the AAFHTN5-25 and AAFHTN5-30 mesh pre-filters. Replace it once every 12 months, or earlier at a pressure drop of 350 mbar.
Spare element AAFHTN5-2760V for the AAFHTN5-2760 mesh pre-filter. Replace it once every 12 months, or earlier at a pressure drop of 350 mbar.
Spare element AAFHTN5-335V for the AAFHTN5-335 mesh pre-filter. Replace it once every 12 months, or earlier at a pressure drop of 350 mbar.
Spare element AAFHTN5-35V for the AAFHTN5-35 and AAFHTN5-60 mesh pre-filters. Replace it once every 12 months, or earlier at a pressure drop of 350 mbar.
Spare element AAFHTN5-510V for the AAFHTN5-510 mesh pre-filter. Replace it once every 12 months, or earlier at a pressure drop of 350 mbar.
Spare element AAFHTN5-780V for the AAFHTN5-780 mesh pre-filter. Replace it once every 12 months, or earlier at a pressure drop of 350 mbar.
Spare element AAFHTN5-78V for the AAFHTN5-78 mesh pre-filter. Replace it once every 12 months, or earlier at a pressure drop of 350 mbar.