Omega Air stainless steel process filters up to 14 and 50 bar

Stainless steel process filters from the Slovenian manufacturer Omega Air clean compressed air where there is a risk of corrosion or where the entire air line must be made of stainless steel — in the food industry, pharmaceuticals, breweries, dairies and chemicals. The housings are made of stainless steel 1.4404, or 1.4301 on request.
The PF, WFIT, WFIF and WFIW ranges work up to 14 bar, the HPF and WHFIT ranges up to 50 bar. The connection is a G 1/4" to G 3" thread, a DN15 to DN200 flange or welding onto a ø 17.2 to 88.9 mm pipe, with flows of 1,250 to 352,000 l/min at 7 bar. The housing holds an element, and the element determines the filtration stage. The filters are part of the range of industrial compressed air filters.
Choose a range
The range is chosen by pressure, connection and housing design. Each tile leads to a range with all its stages and sizes.

PF process filters up to 14 bar
Polished stainless steel housing, G 1/4" to 3" thread, flanges from DN100.

HPF process filters up to 50 bar
Polished stainless steel housing for higher pressure, G 1/2" to 3" thread.
Ranges at a glance
| Process filter ranges | ||||
|---|---|---|---|---|
| Range | Housing | Working pressure | Connection | Filtration stages |
| PF filters | stainless steel 1.4404, polished | 14 bar, 10 bar from DN100 | G 1/4" to 3", DN100 to DN200 | N25, I20, IW20, N5, P, I1, IW1, R, M, S, A, SF |
| HPF filters | stainless steel 1.4404, polished | 50 bar | G 1/2" to 3" | N25, I20, IW20, N5, P, I1, IW1, R, M, S, A, SF |
| WFIT filters | welded stainless steel 1.4404 | 14 bar | G 1/4" to 3" | C, N25, I20, IW20, N5, P, I1, IW1, R, M, S, A |
| WFIF filters | welded stainless steel 1.4404 | 14 bar, 10 bar from DN100 | DN15 to DN200 | C, N25, I20, IW20, N5, P, I1, IW1, R, M, S, A |
| WFIW filters | welded stainless steel 1.4404 | 14 bar | welding ends ø 17.2 to 88.9 mm | C, N25, I20, IW20, N5, P, I1, IW1, R, M, S, A |
| WHFIT filters | welded stainless steel 1.4404 | 50 bar | G 1/2" to 3" | C, N25, I20, IW20, N5, P, I1, IW1, R, M, S, A |
Working pressure, connection and dimensions according to the manufacturer’s technical data sheets.
Filtration stages
The ISO 8573-1 class is written as solid particles – water – oil. The letter x means that the stage does not determine that component.
| Filtration stages | |||||
|---|---|---|---|---|---|
| Stage | Filtration rating | ISO 8573-1 class | Residual oil | Temperature up to | In ranges |
| C – cyclone separator | – | – | – | +120 °C | WFIT, WFIF, WFIW, WHFIT |
| N25 – coarse filter | 25 µm | – | – | +150 °C | PF, HPF, WFIT, WFIF, WFIW, WHFIT |
| I20 – sintered pre-filter | 20 µm | – | – | +150 °C | PF, HPF, WFIT, WFIF, WFIW, WHFIT |
| IW20 – welded pre-filter | 20 µm | – | – | +150 °C | PF, HPF, WFIT, WFIF, WFIW, WHFIT |
| N5 – basic filter | 5 µm | – | – | +150 °C | PF, HPF, WFIT, WFIF, WFIW, WHFIT |
| P – fibre pre-filter | 3 µm | 6-x-x | – | +65 °C | PF, HPF, WFIT, WFIF, WFIW, WHFIT |
| I1 – sintered pre-filter | 1 µm | – | – | +150 °C | PF, HPF, WFIT, WFIF, WFIW, WHFIT |
| IW1 – welded pre-filter | 1 µm | – | – | +150 °C | PF, HPF, WFIT, WFIF, WFIW, WHFIT |
| R – dust filter | 1 µm | 3-x-x | – | +120 °C | PF, HPF, WFIT, WFIF, WFIW, WHFIT |
| M – fine pre-filter | 0.1 µm | 2-x-2 | < 0.1 mg/m³ | +120 °C | PF, HPF, WFIT, WFIF, WFIW, WHFIT |
| S – microfilter | 0.01 µm | 1-x-1 | < 0.01 mg/m³ | +120 °C | PF, HPF, WFIT, WFIF, WFIW, WHFIT |
| A – activated carbon filter | – | 1-x-1 | – | +45 °C | PF, HPF, WFIT, WFIF, WFIW, WHFIT |
| SF – sterile filter | 0.01 µm | 1-x-x | – | +150 °C | PF, HPF |
Solid particle class 1 for activated carbon A only applies when an S microfilter is installed before it. The manufacturer does not state a class for the stainless steel meshes and sintered elements. The temperature is the limit of the element; the housing withstands +150 °C.
#showmore#
How to choose a filter
Pressure first: the PF, WFIT, WFIF and WFIW ranges are rated up to 14 bar (the large flanged sizes from DN100 up to 10 bar), the HPF and WHFIT ranges up to 50 bar.
Then the connection and housing: PF and HPF have a polished stainless steel housing with a thread, WFIT and WHFIT a welded housing with a thread, WFIF a welded housing with flanges and WFIW a welded housing with welding ends for the pipeline. All housings are made of stainless steel 1.4404, or 1.4301 on request.
Finally, the filtration stage according to how clean the air needs to be, and the size according to the flow at your pressure. The welded ranges also have a cyclone separator C, the PF and HPF ranges a sterile element SF.
How to put the filtration together

The stages are arranged from coarse to fine in the direction of flow: first the cyclone separator C (in the welded ranges), then 25 and 5 µm stainless steel meshes, 20 and 1 µm sintered elements, the 3 µm fibre pre-filter, the 1 µm dust filter, the fine pre-filter M, the microfilter S, activated carbon A and finally the sterile element SF. The welded elements IW20 and IW1 are a different design of the 20 and 1 µm stages and are used instead of I20 and I1.
The fine pre-filter M goes before the microfilter S and protects its element. An S microfilter always goes before activated carbon — only with it does solid particle class 1 apply. Activated carbon must not work in an oil-saturated environment.
How to read the ISO 8573-1 purity class
The ISO 8573-1 standard describes the purity of compressed air with three numbers: solid particles, water and oil. The lower the number, the cleaner the air.
The S microfilter with class 1-x-1 ensures the highest purity for solid particles and oil, but it does not deal with humidity. Filters only trap water that has already condensed. Water vapour is removed by a compressed air dryer.
Flow at a different pressure

The flows in the tables apply to a pressure of 7 bar and a temperature of +20 °C. At a different pressure, multiply the flow by the correction factor: at 14 bar it is 1.88, at 4 bar 0.63. For the HPF and WHFIT ranges at 50 bar, it is 6.38.
Example: the PFM-010 has a flow of 2,500 l/min at 7 bar and 2,500 × 1.88 = 4,700 l/min at 14 bar.
| Flow correction factor by pressure – PF, WFIT, WFIF and WFIW | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Pressure (bar) | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 | 14 |
| Factor | 0.38 | 0.5 | 0.63 | 0.75 | 0.88 | 1 | 1.13 | 1.25 | 1.38 | 1.5 | 1.63 | 1.75 | 1.88 |
| Flow correction factor by pressure – HPF and WHFIT | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| Pressure (bar) | 3 | 5 | 7 | 10 | 13 | 16 | 20 | 30 | 40 | 50 |
| Factor | 0.5 | 0.75 | 1 | 1.38 | 1.75 | 2.13 | 2.63 | 3.88 | 5.13 | 6.38 |
Housing and materials

PF and HPF filters: stainless steel 1.4404, 1.4301 on request, EPDM seals (FKM or silicone on request), outer surface polished to Ra 1.6. WFIT and WHFIT filters: welded stainless steel 1.4404, 1.4301 on request, FKM seals (EPDM or silicone on request). WFIF filters: welded stainless steel 1.4404, 1.4301 on request, FKM seals (EPDM or silicone on request), flanges according to EN 1092-1/11 PN16, ANSI B16.5 WN Class 150 on request. WFIW filters: welded stainless steel 1.4404, 1.4301 on request, FKM seals (EPDM or silicone on request), welding ends for the pipeline.
The housing withstands temperatures from −20 to +150 °C; the actual limit depends on the seals and the element. For oil separation, a coalescing element (M or S) is fitted in the housing; the air flows through it from the inside out, and the filter is mounted head up with the bowl down.
The filter is supplied with an element, without a condensate drain.
Accessories

MDHI 50-K gauge
A differential pressure gauge with connecting tubes shows the pressure drop across the element, for the welded ranges.
Where process filters are used
The manufacturer designs them for packaging lines, biotechnology, breweries, dairies, fermentation processes, food and beverages, pharmaceuticals, hospitals and the chemical industry, and the welded WFIT, WFIF and WFIW ranges also for petrochemicals. Use with technical gases other than air is assessed separately.
When stainless steel is not needed, there are Omega Air industrial filters; for higher pressures, HF filters up to 50 bar and high-pressure filters up to 420 bar.
Ventilek’s tip
The element sets the temperature limit, not the housing. The stainless steel housing withstands +150 °C, as do the meshes and sintered elements. The dust filter, fine pre-filter and microfilter, however, only +120 °C, the fibre pre-filter +65 °C and activated carbon +45 °C — choose the stage accordingly.
- What is the difference between PF and WFIT?
- Both ranges have a stainless steel 1.4404 housing with a thread and work up to 14 bar. PF has a polished surface and EPDM seals, WFIT a welded housing and FKM seals. The elements are the same for both ranges.
- When should I choose HPF or WHFIT?
- When the pressure in the air line is higher than 14 bar. Both ranges work up to 50 bar and take the same elements as the PF range; HPF has a polished housing, WHFIT a welded one.
- When should I choose WFIW?
- When the filter is welded directly into a stainless steel pipeline. Depending on the size, the housing ends match a pipe diameter of ø 17.2 to 88.9 mm.
- How do I choose the size?
- By the flow at your pressure. The flows in the tables apply to 7 bar; at a different pressure, multiply them by the correction factor.
- How often should the elements be replaced?
- At least once every 12 months. Once a year, also check the housing for visible damage.
- Does one element fit several ranges?
- Yes. All ranges take PF range elements — for example, the PFM-010V fits the PFM-010, HPFM-010, WFITM-010, WFIFM-010, WFIWM-010 and WHFITM-010 filters.
- Is a condensate drain included with the filter?
- No. The filter is supplied with an element; the condensate drain is ordered separately. For the ranges up to 14 bar, the AOK20SS float drain is suitable; for the HPF and WHFIT ranges, the AOK50SS or the TD420M timed drain.
-
PF process filters
-
HPF process filters
-
WFIT welded filters
-
WFIF welded filters
-
WFIW welded filters
-
WHFIT welded filters
-
Spare elements
Bestsellers
Product sorting
List of products
Spare element PFM-010V for PF, HPF, WFIT, WFIF, WFIW, WHFIT and SPF fine pre-filters of size 010 — borosilicate microfibres. Replace it at least once every 12 months. The same...
Spare element PFI1-200V for PF, HPF, WFIT, WFIF, WFIW, WHFIT and SPF sintered pre-filters of size 200 — sintered stainless steel 1.4404. Replace it at least once every 12...
Spare element PFI20-010V for PF, HPF, WFIT, WFIF, WFIW, WHFIT and SPF sintered pre-filters of size 010 — sintered stainless steel 1.4404. Replace it at least once every 12...
With a DN150 connection and a flow of 224,000 l/min at 7 bar, the PFA-1200 activated carbon filter removes oil vapours, hydrocarbons and odours. Working pressure up to 10 bar,...
With a DN200 connection and a flow of 288,000 l/min at 7 bar, the PFA-1800 activated carbon filter removes oil vapours, hydrocarbons and odours. Working pressure up to 10 bar,...
With a DN200 connection and a flow of 352,000 l/min at 7 bar, the PFA-2000 activated carbon filter removes oil vapours, hydrocarbons and odours. Working pressure up to 10 bar,...
With a DN100 connection and a flow of 84,000 l/min at 7 bar, the PFA-450 activated carbon filter removes oil vapours, hydrocarbons and odours. Working pressure up to 10 bar,...
With a DN100 connection and a flow of 112,000 l/min at 7 bar, the PFA-600 activated carbon filter removes oil vapours, hydrocarbons and odours. Working pressure up to 10 bar,...
With a DN150 connection and a flow of 160,000 l/min at 7 bar, the PFA-900 activated carbon filter removes oil vapours, hydrocarbons and odours. Working pressure up to 10 bar,...
With a DN150 connection and a flow of 224,000 l/min at 7 bar, the WFIFA-1200 activated carbon filter removes oil vapours, hydrocarbons and odours. Working pressure up to 10 bar,...
With a DN200 connection and a flow of 288,000 l/min at 7 bar, the WFIFA-1800 activated carbon filter removes oil vapours, hydrocarbons and odours. Working pressure up to 10 bar,...
With a DN200 connection and a flow of 352,000 l/min at 7 bar, the WFIFA-2000 activated carbon filter removes oil vapours, hydrocarbons and odours. Working pressure up to 10 bar,...
With a DN100 connection and a flow of 84,000 l/min at 7 bar, the WFIFA-450 activated carbon filter removes oil vapours, hydrocarbons and odours. Working pressure up to 10 bar,...
With a DN100 connection and a flow of 112,000 l/min at 7 bar, the WFIFA-600 activated carbon filter removes oil vapours, hydrocarbons and odours. Working pressure up to 10 bar,...
With a DN150 connection and a flow of 160,000 l/min at 7 bar, the WFIFA-900 activated carbon filter removes oil vapours, hydrocarbons and odours. Working pressure up to 10 bar,...
With a DN150 connection and a flow of 224,000 l/min at 7 bar, the WFIFN5-1200 basic filter traps solid contaminants larger than 5 µm. Working pressure up to 10 bar, welded...
With a DN200 connection and a flow of 288,000 l/min at 7 bar, the WFIFN5-1800 basic filter traps solid contaminants larger than 5 µm. Working pressure up to 10 bar, welded...
With a DN200 connection and a flow of 352,000 l/min at 7 bar, the WFIFN5-2000 basic filter traps solid contaminants larger than 5 µm. Working pressure up to 10 bar, welded...
With a DN100 connection and a flow of 112,000 l/min at 7 bar, the WFIFN5-600 basic filter traps solid contaminants larger than 5 µm. Working pressure up to 10 bar, welded...
With a DN150 connection and a flow of 160,000 l/min at 7 bar, the WFIFN5-900 basic filter traps solid contaminants larger than 5 µm. Working pressure up to 10 bar, welded...
With a DN150 connection and a flow of 224,000 l/min at 7 bar, the PFN25-1200 coarse filter traps coarse solid contaminants larger than 25 µm and protects the finer stages after...
With a DN200 connection and a flow of 288,000 l/min at 7 bar, the PFN25-1800 coarse filter traps coarse solid contaminants larger than 25 µm and protects the finer stages after...
With a DN200 connection and a flow of 352,000 l/min at 7 bar, the PFN25-2000 coarse filter traps coarse solid contaminants larger than 25 µm and protects the finer stages after...
With a DN100 connection and a flow of 112,000 l/min at 7 bar, the PFN25-600 coarse filter traps coarse solid contaminants larger than 25 µm and protects the finer stages after...
With a DN150 connection and a flow of 160,000 l/min at 7 bar, the PFN25-900 coarse filter traps coarse solid contaminants larger than 25 µm and protects the finer stages after...
With a DN150 connection and a flow of 224,000 l/min at 7 bar, the WFIFN25-1200 coarse filter traps coarse solid contaminants larger than 25 µm and protects the finer stages...
With a DN200 connection and a flow of 288,000 l/min at 7 bar, the WFIFN25-1800 coarse filter traps coarse solid contaminants larger than 25 µm and protects the finer stages...
With a DN200 connection and a flow of 352,000 l/min at 7 bar, the WFIFN25-2000 coarse filter traps coarse solid contaminants larger than 25 µm and protects the finer stages...
With a DN100 connection and a flow of 112,000 l/min at 7 bar, the WFIFN25-600 coarse filter traps coarse solid contaminants larger than 25 µm and protects the finer stages after...
With a DN150 connection and a flow of 160,000 l/min at 7 bar, the WFIFN25-900 coarse filter traps coarse solid contaminants larger than 25 µm and protects the finer stages after...
With a DN150 connection and a flow of 224,000 l/min at 7 bar, the PFR-1200 dust filter traps solid particles and dust larger than 1 µm, solid particle class 3 according to ISO...
With a DN200 connection and a flow of 288,000 l/min at 7 bar, the PFR-1800 dust filter traps solid particles and dust larger than 1 µm, solid particle class 3 according to ISO...
With a DN200 connection and a flow of 352,000 l/min at 7 bar, the PFR-2000 dust filter traps solid particles and dust larger than 1 µm, solid particle class 3 according to ISO...
With a DN100 connection and a flow of 84,000 l/min at 7 bar, the PFR-450 dust filter traps solid particles and dust larger than 1 µm, solid particle class 3 according to ISO...
With a DN100 connection and a flow of 112,000 l/min at 7 bar, the PFR-600 dust filter traps solid particles and dust larger than 1 µm, solid particle class 3 according to ISO...
With a DN150 connection and a flow of 160,000 l/min at 7 bar, the PFR-900 dust filter traps solid particles and dust larger than 1 µm, solid particle class 3 according to ISO...
With a DN150 connection and a flow of 224,000 l/min at 7 bar, the WFIFR-1200 dust filter traps solid particles and dust larger than 1 µm, solid particle class 3 according to ISO...
With a DN200 connection and a flow of 288,000 l/min at 7 bar, the WFIFR-1800 dust filter traps solid particles and dust larger than 1 µm, solid particle class 3 according to ISO...
With a DN200 connection and a flow of 352,000 l/min at 7 bar, the WFIFR-2000 dust filter traps solid particles and dust larger than 1 µm, solid particle class 3 according to ISO...
With a DN100 connection and a flow of 84,000 l/min at 7 bar, the WFIFR-450 dust filter traps solid particles and dust larger than 1 µm, solid particle class 3 according to ISO...