WFIFI20 sintered stainless steel pre-filters up to 14 bar

The WFIFI20 sintered pre-filter has an element made of sintered stainless steel 1.4404 and traps solid particles larger than 20 µm. It goes at the start of the filtration in the WFIF range: it protects the finer stages after it.
The WFIFI20 filter comes in 16 sizes (DN15 to DN200) with flows of 2,500 to 352,000 l/min at 7 bar; working pressure up to 14 bar, sizes from DN100 up to 10 bar. It is one of the stages of the WFIF filters — the housing is the same for all stages, only the element differs.
WFIFI20 filters by size
The size determines the connection and the flow. Each size has its own PF range spare element.
| WFIFI20 filters and spare elements by size | ||||||
|---|---|---|---|---|---|---|
| Filter | Connection | l/min at 7 bar | Nm³/h at 7 bar | Height A × diameter C | Weight | Spare element |
| WFIFI20-010 | DN15 flange | 2,500 | 150 | 230 × 76.1 mm | 3.5 kg | PFI20-010V |
| WFIFI20-018 | DN20 flange | 3,750 | 225 | 263 × 76.1 mm | 4.3 kg | PFI20-018V |
| WFIFI20-030 | DN25 flange | 5,250 | 315 | 279 × 88.9 mm | 5.7 kg | PFI20-030V |
| WFIFI20-047 | DN32 flange | 7,000 | 420 | 348 × 88.9 mm | 6.6 kg | PFI20-047V |
| WFIFI20-070 | DN40 flange | 10,000 | 600 | 391 × 114.3 mm | 8 kg | PFI20-070V |
| WFIFI20-094 | DN50 flange | 15,000 | 900 | 444 × 114.3 mm | 9.8 kg | PFI20-094V |
| WFIFI20-150 | DN50 flange | 21,000 | 1,260 | 571 × 114.3 mm | 11 kg | PFI20-150V |
| WFIFI20-175 | DN65 flange | 28,000 | 1,680 | 752 × 139.7 mm | 14.2 kg | PFI20-175V |
| WFIFI20-200 | DN80 flange | 40,000 | 2,400 | 978 × 139.7 mm | 21.2 kg | PFI20-200V |
| WFIFI20-240 | DN80 flange | 60,000 | 3,600 | 1,041 × 168.3 mm | 22.9 kg | PFI20-240V |
| WFIFI20-450 | DN100 flange | 84,000 | 5,040 | 981 × 219.1 mm | 55 kg | 3× PFI20-175V |
| WFIFI20-600 | DN100 flange | 112,000 | 6,720 | 1,288 × 219.1 mm | 64 kg | 3× PFI20-200V |
| WFIFI20-900 | DN150 flange | 160,000 | 9,600 | 1,310 × 273 mm | 87 kg | 4× PFI20-200V |
| WFIFI20-1200 | DN150 flange | 224,000 | 13,440 | 1,351 × 323.9 mm | 110 kg | 6× PFI20-200V |
| WFIFI20-1800 | DN200 flange | 288,000 | 17,280 | 1,496 × 406.4 mm | 200 kg | 8× PFI20-200V |
| WFIFI20-2000 | DN200 flange | 352,000 | 21,120 | 1,496 × 406.4 mm | 200 kg | 10× PFI20-200V |
The flows apply to a pressure of 7 bar and a temperature of +20 °C. Dimensions according to the manufacturer’s technical data sheet; you will find further data on the product page of each filter.
#showmore#
When to use it
The 20 µm sintered pre-filter is suitable at the start of the filtration. The element is made entirely of stainless steel and, like the housing, withstands up to +150 °C. It does not trap oil; the manufacturer does not state an ISO 8573-1 class for it.
Where to place it

At the start of the filtration or after the WFIFN25 coarse filter, before the WFIFN5 basic filter or the WFIFM fine pre-filter.
Flow by pressure
The catalogue flows apply to a pressure of 7 bar and a temperature of +20 °C. At a different pressure, they are multiplied by the correction factor: 1.88 at 14 bar.
| WFIFI20 filter flow in l/min by pressure | ||||
|---|---|---|---|---|
| Size (connection) | 4 bar | 7 bar | 10 bar | 14 bar |
| 010 (DN15 flange) | 1,575 | 2,500 | 3,450 | 4,700 |
| 018 (DN20 flange) | 2,363 | 3,750 | 5,175 | 7,050 |
| 030 (DN25 flange) | 3,308 | 5,250 | 7,245 | 9,870 |
| 047 (DN32 flange) | 4,410 | 7,000 | 9,660 | 13,160 |
| 070 (DN40 flange) | 6,300 | 10,000 | 13,800 | 18,800 |
| 094 (DN50 flange) | 9,450 | 15,000 | 20,700 | 28,200 |
| 150 (DN50 flange) | 13,230 | 21,000 | 28,980 | 39,480 |
| 175 (DN65 flange) | 17,640 | 28,000 | 38,640 | 52,640 |
| 200 (DN80 flange) | 25,200 | 40,000 | 55,200 | 75,200 |
| 240 (DN80 flange) | 37,800 | 60,000 | 82,800 | 112,800 |
| 450 (DN100 flange) | 52,920 | 84,000 | 115,920 | – |
| 600 (DN100 flange) | 70,560 | 112,000 | 154,560 | – |
| 900 (DN150 flange) | 100,800 | 160,000 | 220,800 | – |
| 1200 (DN150 flange) | 141,120 | 224,000 | 309,120 | – |
| 1800 (DN200 flange) | 181,440 | 288,000 | 397,440 | – |
| 2000 (DN200 flange) | 221,760 | 352,000 | 485,760 | – |
Element, condensate drainage and maintenance

A PF range element is fitted in the housing — for example, the PFI20-010V for the WFIFI20-010. The same element also fits the PFI20-010, HPFI20-010, WFITI20-010, WFIWI20-010 and WHFITI20-010. Flanged filters from DN100 have several elements — their number is given in the table for each size. Element working temperature +1.5 to +150 °C.
The filter is supplied with an element, without a condensate drain. For WFIF filters, the manufacturer offers the AOK20SS stainless steel float drain up to 20 bar and +65 °C and, for the head, the MDHI 50-K differential pressure gauge. The drain outlet in the bottom has a G 1/2" thread, G 1" for sizes from DN100.
Replace the element at least once every 12 months. Once a year, also check the housing for visible damage.
Accessories for WFIFI20 filters

MDHI 50-K gauge
Differential pressure gauge with connecting tubes; it shows how clogged the element is.
The same stage in other ranges
Stage I20 also comes in the PFI20 filters up to 14 bar, HPFI20 filters up to 50 bar, WFITI20 filters up to 14 bar, WFIWI20 filters up to 14 bar and WHFITI20 filters up to 50 bar. The elements are the same for all ranges.
Ventilek’s tip
Coarse contaminants first. The sintered pre-filter I20 traps larger particles before they reach the fine pre-filter, whose element then lasts longer.
- What filtration rating does the WFIFI20 pre-filter have?
- The element traps particles larger than 20 µm. The manufacturer does not state an ISO 8573-1 class for it.
- Does it also trap oil?
- No. Oil aerosol is handled by the fine pre-filter M.
- When should the element be replaced?
- At least once every 12 months.
Bestsellers
Product sorting
List of products
With a DN15 connection and a flow of 2,500 l/min at 7 bar, the WFIFI20-010 sintered pre-filter traps solid contaminants larger than 20 µm and protects the finer stages after it....
With a DN20 connection and a flow of 3,750 l/min at 7 bar, the WFIFI20-018 sintered pre-filter traps solid contaminants larger than 20 µm and protects the finer stages after it....
With a DN25 connection and a flow of 5,250 l/min at 7 bar, the WFIFI20-030 sintered pre-filter traps solid contaminants larger than 20 µm and protects the finer stages after it....
With a DN32 connection and a flow of 7,000 l/min at 7 bar, the WFIFI20-047 sintered pre-filter traps solid contaminants larger than 20 µm and protects the finer stages after it....
With a DN40 connection and a flow of 10,000 l/min at 7 bar, the WFIFI20-070 sintered pre-filter traps solid contaminants larger than 20 µm and protects the finer stages after...
With a DN50 connection and a flow of 15,000 l/min at 7 bar, the WFIFI20-094 sintered pre-filter traps solid contaminants larger than 20 µm and protects the finer stages after...
With a DN150 connection and a flow of 224,000 l/min at 7 bar, the WFIFI20-1200 sintered pre-filter traps solid contaminants larger than 20 µm and protects the finer stages after...
With a DN50 connection and a flow of 21,000 l/min at 7 bar, the WFIFI20-150 sintered pre-filter traps solid contaminants larger than 20 µm and protects the finer stages after...
With a DN65 connection and a flow of 28,000 l/min at 7 bar, the WFIFI20-175 sintered pre-filter traps solid contaminants larger than 20 µm and protects the finer stages after...
With a DN200 connection and a flow of 288,000 l/min at 7 bar, the WFIFI20-1800 sintered pre-filter traps solid contaminants larger than 20 µm and protects the finer stages after...
With a DN80 connection and a flow of 40,000 l/min at 7 bar, the WFIFI20-200 sintered pre-filter traps solid contaminants larger than 20 µm and protects the finer stages after...
With a DN200 connection and a flow of 352,000 l/min at 7 bar, the WFIFI20-2000 sintered pre-filter traps solid contaminants larger than 20 µm and protects the finer stages after...
With a DN80 connection and a flow of 60,000 l/min at 7 bar, the WFIFI20-240 sintered pre-filter traps solid contaminants larger than 20 µm and protects the finer stages after...
With a DN100 connection and a flow of 84,000 l/min at 7 bar, the WFIFI20-450 sintered pre-filter traps solid contaminants larger than 20 µm and protects the finer stages after...
With a DN100 connection and a flow of 112,000 l/min at 7 bar, the WFIFI20-600 sintered pre-filter traps solid contaminants larger than 20 µm and protects the finer stages after...
With a DN150 connection and a flow of 160,000 l/min at 7 bar, the WFIFI20-900 sintered pre-filter traps solid contaminants larger than 20 µm and protects the finer stages after...