WFITP fibre pre-filters for dust up to 14 bar

The WFITP fibre pre-filter has a pleated element of acrylic fibres and cellulose and traps solid particles and dust larger than 3 µm — solid particle class 6 according to ISO 8573-1. The housing is made of stainless steel 1.4404.
The WFITP filter comes in 12 sizes (G 1/4" to 3") with flows of 1,250 to 60,000 l/min at 7 bar; working pressure up to 14 bar. It is one of the stages of the WFIT filters — the housing is the same for all stages, only the element differs.
WFITP filters by size
The size determines the connection and the flow. Each size has its own PF range spare element.
| WFITP filters and spare elements by size | ||||||
|---|---|---|---|---|---|---|
| Filter | Connection | l/min at 7 bar | Nm³/h at 7 bar | Height A × diameter C | Weight | Spare element |
| WFITP-005 | G 1/4" | 1,250 | 75 | 204 × 76.1 mm | 1.9 kg | PFP-005V |
| WFITP-007 | G 3/8" | 1,750 | 105 | 235 × 76.1 mm | 2.1 kg | PFP-007V |
| WFITP-010 | G 1/2" | 2,500 | 150 | 239 × 76.1 mm | 2.2 kg | PFP-010V |
| WFITP-018 | G 3/4" | 3,750 | 225 | 263 × 76.1 mm | 2.3 kg | PFP-018V |
| WFITP-030 | G 1" | 5,250 | 315 | 278 × 88.9 mm | 3.1 kg | PFP-030V |
| WFITP-047 | G 1 1/4" | 7,000 | 420 | 348 × 88.9 mm | 3.4 kg | PFP-047V |
| WFITP-070 | G 1 1/2" | 10,000 | 600 | 376 × 114.3 mm | 4.6 kg | PFP-070V |
| WFITP-094 | G 2" | 15,000 | 900 | 458 × 114.3 mm | 5.4 kg | PFP-094V |
| WFITP-150 | G 2" | 21,000 | 1,260 | 571 × 114.3 mm | 6.1 kg | PFP-150V |
| WFITP-175 | G 2 1/2" | 28,000 | 1,680 | 722 × 139.7 mm | 11.4 kg | PFP-175V |
| WFITP-200 | G 3" | 40,000 | 2,400 | 1,004 × 139.7 mm | 12 kg | PFP-200V |
| WFITP-240 | G 3" | 60,000 | 3,600 | 1,029 × 168.3 mm | 16 kg | PFP-240V |
The flows apply to a pressure of 7 bar and a temperature of +20 °C. Dimensions according to the manufacturer’s technical data sheet; you will find further data on the product page of each filter.
#showmore#
When to use it
The fibre pre-filter P is suitable where the air contains dust and finer contaminants that a stainless steel mesh lets through. The element only withstands +65 °C — for warmer air, there are meshes and sintered elements up to +150 °C.
The manufacturer does not state an oil class for it; oil aerosol is handled by the fine pre-filter M.
Where to place it

After the WFITN5 basic filter or the WFITI20 sintered pre-filter, before the WFITR dust filter or the WFITM fine pre-filter.
Flow by pressure
The catalogue flows apply to a pressure of 7 bar and a temperature of +20 °C. At a different pressure, they are multiplied by the correction factor: 1.88 at 14 bar.
| WFITP filter flow in l/min by pressure | ||||
|---|---|---|---|---|
| Size (connection) | 4 bar | 7 bar | 10 bar | 14 bar |
| 005 (G 1/4") | 788 | 1,250 | 1,725 | 2,350 |
| 007 (G 3/8") | 1,103 | 1,750 | 2,415 | 3,290 |
| 010 (G 1/2") | 1,575 | 2,500 | 3,450 | 4,700 |
| 018 (G 3/4") | 2,363 | 3,750 | 5,175 | 7,050 |
| 030 (G 1") | 3,308 | 5,250 | 7,245 | 9,870 |
| 047 (G 1 1/4") | 4,410 | 7,000 | 9,660 | 13,160 |
| 070 (G 1 1/2") | 6,300 | 10,000 | 13,800 | 18,800 |
| 094 (G 2") | 9,450 | 15,000 | 20,700 | 28,200 |
| 150 (G 2") | 13,230 | 21,000 | 28,980 | 39,480 |
| 175 (G 2 1/2") | 17,640 | 28,000 | 38,640 | 52,640 |
| 200 (G 3") | 25,200 | 40,000 | 55,200 | 75,200 |
| 240 (G 3") | 37,800 | 60,000 | 82,800 | 112,800 |
Element, condensate drainage and maintenance

A PF range element is fitted in the housing — for example, the PFP-010V for the WFITP-010. The same element also fits the PFP-010, HPFP-010, WFIFP-010, WFIWP-010 and WHFITP-010. Element working temperature +1.5 to +65 °C.
The filter is supplied with an element, without a condensate drain. For WFIT filters, the manufacturer offers the AOK20SS stainless steel float drain up to 20 bar and +65 °C and, for the head, the MDHI 50-K differential pressure gauge. The drain outlet in the bottom has a G 1/2" thread.
Replace the element at least once every 12 months. Once a year, also check the housing for visible damage.
Accessories for WFITP filters

MDHI 50-K gauge
Differential pressure gauge with connecting tubes; it shows how clogged the element is.
The same stage in other ranges
Stage P also comes in the PFP filters up to 14 bar, HPFP filters up to 50 bar, WFIFP filters up to 14 bar, WFIWP filters up to 14 bar and WHFITP filters up to 50 bar. The elements are the same for all ranges.
Ventilek’s tip
Fibres only up to +65 °C. The fibre element P is suitable for cooler air. For warmer air, choose the N5 mesh or a sintered pre-filter — they withstand +150 °C.
- What filtration rating does the WFITP fibre pre-filter have?
- The element traps particles larger than 3 µm, solid particle class 6 according to ISO 8573-1.
- What temperature does it withstand?
- The element from +1.5 to +65 °C.
- When should the element be replaced?
- At least once every 12 months.
Product sorting
List of products
With a G 1/4" connection and a flow of 1,250 l/min at 7 bar, the WFITP-005 fibre pre-filter traps solid particles and dust larger than 3 µm, solid particle class 6 according to...
With a G 3/8" connection and a flow of 1,750 l/min at 7 bar, the WFITP-007 fibre pre-filter traps solid particles and dust larger than 3 µm, solid particle class 6 according to...
With a G 1/2" connection and a flow of 2,500 l/min at 7 bar, the WFITP-010 fibre pre-filter traps solid particles and dust larger than 3 µm, solid particle class 6 according to...
With a G 3/4" connection and a flow of 3,750 l/min at 7 bar, the WFITP-018 fibre pre-filter traps solid particles and dust larger than 3 µm, solid particle class 6 according to...
With a G 1" connection and a flow of 5,250 l/min at 7 bar, the WFITP-030 fibre pre-filter traps solid particles and dust larger than 3 µm, solid particle class 6 according to...
With a G 1 1/4" connection and a flow of 7,000 l/min at 7 bar, the WFITP-047 fibre pre-filter traps solid particles and dust larger than 3 µm, solid particle class 6 according...
With a G 1 1/2" connection and a flow of 10,000 l/min at 7 bar, the WFITP-070 fibre pre-filter traps solid particles and dust larger than 3 µm, solid particle class 6 according...
With a G 2" connection and a flow of 15,000 l/min at 7 bar, the WFITP-094 fibre pre-filter traps solid particles and dust larger than 3 µm, solid particle class 6 according to...
With a G 2" connection and a flow of 21,000 l/min at 7 bar, the WFITP-150 fibre pre-filter traps solid particles and dust larger than 3 µm, solid particle class 6 according to...
With a G 2 1/2" connection and a flow of 28,000 l/min at 7 bar, the WFITP-175 fibre pre-filter traps solid particles and dust larger than 3 µm, solid particle class 6 according...
With a G 3" connection and a flow of 40,000 l/min at 7 bar, the WFITP-200 fibre pre-filter traps solid particles and dust larger than 3 µm, solid particle class 6 according to...
With a G 3" connection and a flow of 60,000 l/min at 7 bar, the WFITP-240 fibre pre-filter traps solid particles and dust larger than 3 µm, solid particle class 6 according to...