HFB high-pressure coarse filters with sintered element up to 50 bar

The HFB coarse filter has a sintered element and traps solid particles larger than 15 µm. It is the first filtration stage: it removes larger contaminants before they reach the finer stages, which then last longer.
The HFB filter comes in 9 sizes with G 1/2" to G 3" threads and flows of 1,183 to 46,000 l/min at 7 bar; working pressure up to 50 bar. It is one of the stages of the HF high-pressure filters — the housing is the same for all stages, only the element differs.
HFB filters by size
The size determines the thread and the flow. Each size has its own spare element.
| HFB filters and spare elements by size | ||||
|---|---|---|---|---|
| Filter | Thread | l/min at 7 bar | Nm³/h at 7 bar | Spare element |
| HFB-007 | G 1/2" | 1,183 | 71 | HFB-007V |
| HFB-010 | G 3/4" | 1,867 | 112 | HFB-010V |
| HFB-018 | G 1" | 3,400 | 204 | HFB-018V |
| HFB-047 | G 1 1/2" | 4,700 | 282 | HFB-047V |
| HFB-070 | G 1 1/2" | 6,667 | 400 | HFB-070V |
| HFB-094 | G 2" | 8,233 | 494 | HFB-094V |
| HFB-150 | G 2" | 13,317 | 799 | HFB-150V |
| HFB-200 | G 3" | 36,000 | 2,160 | HFB-200V |
| HFB-240 | G 3" | 46,000 | 2,760 | HFB-240V |
The flows apply to a pressure of 7 bar and a temperature of +20 °C. You will find the dimensions and weight on the product page of each filter.
#showmore#
When to use it
A coarse filter suits the start of the filtration, where larger contaminants from the compressor or the air line enter the air. On its own it achieves solid particle class 7; it does not trap oil or vapours.
Where to place it

At the start of the filtration, before the HFP basic filter or HFR dust filter.
Flow by pressure
The catalogue flows apply to a pressure of 7 bar and a temperature of +20 °C. At a higher pressure the filter passes more air: at 50 bar, 6.38 times as much as at 7 bar.
| HFB filter flow in l/min by pressure | ||||||
|---|---|---|---|---|---|---|
| Size (thread) | 5 bar | 7 bar | 10 bar | 16 bar | 30 bar | 50 bar |
| 007 (G 1/2") | 887 | 1,183 | 1,633 | 2,520 | 4,590 | 7,548 |
| 010 (G 3/4") | 1,400 | 1,867 | 2,576 | 3,977 | 7,244 | 11,911 |
| 018 (G 1") | 2,550 | 3,400 | 4,692 | 7,242 | 13,192 | 21,692 |
| 047 (G 1 1/2") | 3,525 | 4,700 | 6,486 | 10,011 | 18,236 | 29,986 |
| 070 (G 1 1/2") | 5,000 | 6,667 | 9,200 | 14,201 | 25,868 | 42,535 |
| 094 (G 2") | 6,175 | 8,233 | 11,362 | 17,536 | 31,944 | 52,527 |
| 150 (G 2") | 9,988 | 13,317 | 18,377 | 28,365 | 51,670 | 84,962 |
| 200 (G 3") | 27,000 | 36,000 | 49,680 | 76,680 | 139,680 | 229,680 |
| 240 (G 3") | 34,500 | 46,000 | 63,480 | 97,980 | 178,480 | 293,480 |
Element, drain and maintenance

The housing holds a single element, a different one for each size — for example HFB-007V for the HFB-007. Working temperature +1.5 to +65 °C, pressure up to 50 bar.
The filter is supplied without a condensate drain. For pressures up to 50 bar, the AOK 50B and AOK 50SS float drains are suitable; they work reliably from 10 bar.
Replace the element at least once a year or at a pressure drop of 350 mbar. The pressure drop is shown by the MDHI 50 differential pressure gauge.
Accessories for HFB filters

MDHI 50 differential pressure gauge
Shows the pressure drop of the element; it is mounted on the filter head.
Ventilek’s tip
A coarse filter spares the fine ones. When larger contaminants break loose in the air line, the B sintered element traps them, and the fine elements after it do not clog so quickly.
- What rating does the HFB coarse filter have?
- 15 µm, solid particle class 7 according to ISO 8573-1.
- Does it also trap oil?
- No. For oil, there are the HFM fine pre-filters and HFS microfilters.
- When should the element be replaced?
- At least once a year or at a pressure drop of 350 mbar.
Product sorting
List of products
With a G 3" thread and a flow of 36,000 l/min at 7 bar, the HFB-200 coarse filter traps coarse solid contaminants larger than 15 µm and protects the finer stages after it....
With a G 3" thread and a flow of 46,000 l/min at 7 bar, the HFB-240 coarse filter traps coarse solid contaminants larger than 15 µm and protects the finer stages after it....
Spare element HFB-007V for the HFB-007 coarse filter with a G 1/2" thread. Recommended replacement at least once a year or at a pressure drop of 350 mbar.
Spare element HFB-010V for the HFB-010 coarse filter with a G 3/4" thread. Recommended replacement at least once a year or at a pressure drop of 350 mbar.
Spare element HFB-018V for the HFB-018 coarse filter with a G 1" thread. Recommended replacement at least once a year or at a pressure drop of 350 mbar.
Spare element HFB-047V for the HFB-047 coarse filter with a G 1 1/2" thread. Recommended replacement at least once a year or at a pressure drop of 350 mbar.
Spare element HFB-070V for the HFB-070 coarse filter with a G 1 1/2" thread. Recommended replacement at least once a year or at a pressure drop of 350 mbar.
Spare element HFB-094V for the HFB-094 coarse filter with a G 2" thread. Recommended replacement at least once a year or at a pressure drop of 350 mbar.
Spare element HFB-150V for the HFB-150 coarse filter with a G 2" thread. Recommended replacement at least once a year or at a pressure drop of 350 mbar.
Spare element HFB-200V for the HFB-200 coarse filter with a G 3" thread. Recommended replacement at least once a year or at a pressure drop of 350 mbar.