HFM high-pressure fine pre-filters for particles and oil up to 50 bar

The HFM fine pre-filter is a coalescing filter for fine solid particles, water and oil aerosol. It traps particles larger than 0.1 µm and merges tiny oil droplets into larger ones; residual oil is below 0.1 mg/m³.
The HFM filter comes in 9 sizes with G 1/2" to G 3" threads and flows of 1,183 to 46,000 l/min at 7 bar; working pressure up to 50 bar. It is one of the stages of the HF high-pressure filters — the housing is the same for all stages, only the element differs.
HFM filters by size
The size determines the thread and the flow. Each size has its own spare element.
| HFM filters and spare elements by size | ||||
|---|---|---|---|---|
| Filter | Thread | l/min at 7 bar | Nm³/h at 7 bar | Spare element |
| HFM-007 | G 1/2" | 1,183 | 71 | HFM-007V |
| HFM-010 | G 3/4" | 1,867 | 112 | HFM-010V |
| HFM-018 | G 1" | 3,400 | 204 | HFM-018V |
| HFM-047 | G 1 1/2" | 4,700 | 282 | HFM-047V |
| HFM-070 | G 1 1/2" | 6,667 | 400 | HFM-070V |
| HFM-094 | G 2" | 8,233 | 494 | HFM-094V |
| HFM-150 | G 2" | 13,317 | 799 | HFM-150V |
| HFM-200 | G 3" | 36,000 | 2,160 | HFM-200V |
| HFM-240 | G 3" | 46,000 | 2,760 | HFM-240V |
The flows apply to a pressure of 7 bar and a temperature of +20 °C. You will find the dimensions and weight on the product page of each filter.
#showmore#
When to use it
The HFM fine pre-filter suits applications where oil in the air is a problem and class 2 for particles and oil is enough.
For the highest purity, 1-x-1, there is the HFS microfilter, and the HFM fine pre-filter goes before it: it traps most of the particles and oil, and the microfilter element then lasts longer.
Where to place it

After the HFR dust filter or HFP basic filter, before the HFS microfilter.
Flow by pressure
The catalogue flows apply to a pressure of 7 bar and a temperature of +20 °C. At a higher pressure the filter passes more air: at 50 bar, 6.38 times as much as at 7 bar.
| HFM filter flow in l/min by pressure | ||||||
|---|---|---|---|---|---|---|
| Size (thread) | 5 bar | 7 bar | 10 bar | 16 bar | 30 bar | 50 bar |
| 007 (G 1/2") | 887 | 1,183 | 1,633 | 2,520 | 4,590 | 7,548 |
| 010 (G 3/4") | 1,400 | 1,867 | 2,576 | 3,977 | 7,244 | 11,911 |
| 018 (G 1") | 2,550 | 3,400 | 4,692 | 7,242 | 13,192 | 21,692 |
| 047 (G 1 1/2") | 3,525 | 4,700 | 6,486 | 10,011 | 18,236 | 29,986 |
| 070 (G 1 1/2") | 5,000 | 6,667 | 9,200 | 14,201 | 25,868 | 42,535 |
| 094 (G 2") | 6,175 | 8,233 | 11,362 | 17,536 | 31,944 | 52,527 |
| 150 (G 2") | 9,988 | 13,317 | 18,377 | 28,365 | 51,670 | 84,962 |
| 200 (G 3") | 27,000 | 36,000 | 49,680 | 76,680 | 139,680 | 229,680 |
| 240 (G 3") | 34,500 | 46,000 | 63,480 | 97,980 | 178,480 | 293,480 |
Element, drain and maintenance

The housing holds a single element, a different one for each size — for example HFM-007V for the HFM-007. Working temperature +1.5 to +65 °C, pressure up to 50 bar.
The filter is supplied without a condensate drain. For pressures up to 50 bar, the AOK 50B and AOK 50SS float drains are suitable; they work reliably from 10 bar.
Replace the element at least once a year or at a pressure drop of 350 mbar. The pressure drop is shown by the MDHI 50 differential pressure gauge.
Accessories for HFM filters

MDHI 50 differential pressure gauge
Shows the pressure drop of the element; it is mounted on the filter head.
Ventilek’s tip
A fine pre-filter protects the microfilter. The HFS microfilter element after it then only deals with the finest particles. A coarser stage should come before the fine pre-filter itself so that dust does not clog it.
- What purity does the HFM fine pre-filter provide?
- Particles down to 0.1 µm and residual oil below 0.1 mg/m³, class 2-x-2 according to ISO 8573-1.
- Why is it a pre-filter and not a microfilter?
- It is installed before the HFS microfilter and protects its element. The microfilter is stage S, with a rating of 0.01 µm.
- When should the element be replaced?
- At least once a year or at a pressure drop of 350 mbar.
Product sorting
List of products
Spare element HFM-007V for the HFM-007 fine pre-filter with a G 1/2" thread. Recommended replacement at least once a year or at a pressure drop of 350 mbar.
With a G 3" thread and a flow of 36,000 l/min at 7 bar, the HFM-200 fine pre-filter traps fine solid particles larger than 0.1 µm, water and oil aerosol; residual oil is below...
With a G 3" thread and a flow of 46,000 l/min at 7 bar, the HFM-240 fine pre-filter traps fine solid particles larger than 0.1 µm, water and oil aerosol; residual oil is below...
Spare element HFM-010V for the HFM-010 fine pre-filter with a G 3/4" thread. Recommended replacement at least once a year or at a pressure drop of 350 mbar.
Spare element HFM-018V for the HFM-018 fine pre-filter with a G 1" thread. Recommended replacement at least once a year or at a pressure drop of 350 mbar.
Spare element HFM-047V for the HFM-047 fine pre-filter with a G 1 1/2" thread. Recommended replacement at least once a year or at a pressure drop of 350 mbar.
Spare element HFM-070V for the HFM-070 fine pre-filter with a G 1 1/2" thread. Recommended replacement at least once a year or at a pressure drop of 350 mbar.
Spare element HFM-094V for the HFM-094 fine pre-filter with a G 2" thread. Recommended replacement at least once a year or at a pressure drop of 350 mbar.
Spare element HFM-150V for the HFM-150 fine pre-filter with a G 2" thread. Recommended replacement at least once a year or at a pressure drop of 350 mbar.
Spare element HFM-200V for the HFM-200 fine pre-filter with a G 3" thread. Recommended replacement at least once a year or at a pressure drop of 350 mbar.
Spare element HFM-240V for the HFM-240 fine pre-filter with a G 3" thread. Recommended replacement at least once a year or at a pressure drop of 350 mbar.