Fine compressed air pre-filters
A fine pre-filter is a coalescing filter: it captures particles from 0.1 µm and oil droplets and aerosol so that at most 0.1 mg/m³ of oil remains in the air – class 2 for solid particles and oil according to ISO 8573-1. It is installed before the microfilter, which it protects from rapid clogging, and before a desiccant dryer. FUTURA air treatment units use a 0.3 µm pre-filter in the same role. The listing shows complete filters, their spare elements and the filters in air treatment units – separate them with the Product type filter.
#showmore#
Where to use a fine pre-filter
Before a microfilter and a desiccant dryer, in paint shops, the food industry and wherever oil mist is a problem. The same grade also includes P-VAC and M-VAC vacuum filters for vacuum pumps and medical vacuum systems.
Fine pre-filter series
| Series | Pressure up to | Connection | Housing |
|---|---|---|---|
| M-VAC | vacuum | 1/8"–3", DN80–DN150 | – |
| P-VACM | vacuum | 1/8"–3" | – |
| AAFHTM | 13 bar | 1/8"–3" | aluminium |
| PFM | 14 bar | 1/4"–3", DN100–DN200 | stainless steel |
| SPFM | 14 bar | 1/4"–3" | stainless steel |
| WFIFM | 14 bar | DN15–DN200 | stainless steel |
| WFITM | 14 bar | 1/4"–3" | stainless steel |
| WFIWM | 14 bar | DN10–DN80 | stainless steel |
| AAFM | 16 bar | 1/4"–3" | aluminium |
| AAFO2 | 16 bar | 1/8"–3" | aluminium |
| AAFSM | 16 bar | 1/8"–3" | aluminium |
| BFM | 16 bar | DN80–DN300 | carbon steel |
| BFHPM | 25 bar | DN80–DN300 | carbon steel |
| HFM | 50 bar | 1/2"–3" | aluminium |
| HFO2 | 50 bar | 1/2"–3" | aluminium |
| HPFM | 50 bar | 1/2"–3" | stainless steel |
| WHFITM | 50 bar | 1/2"–3" | stainless steel |
| CHP1M | 100 bar | 1/4"–2" | carbon steel |
| IHP1M | 100 bar | 1/4"–2" | stainless steel |
| CHP2M | 250 bar | 1/4"–2" | carbon steel |
| IHP2M | 250 bar | 1/4"–2" | stainless steel |
| CHP4M | 420 bar | 1/4"–2" | carbon steel |
| IHP4M | 420 bar | 1/4"–2" | stainless steel |
Filters in air treatment units and more
| Series | Pressure up to | Connection | In the listing |
|---|---|---|---|
| FUTURA | 16 bar | 1/4"–1" | filter, element |
How to choose a fine pre-filter
- Order: a basic filter goes before the fine pre-filter, a 0.01 µm microfilter of the same size after it.
- Pressure and housing: up to 16 bar the aluminium AAF series, up to 16 and 25 bar the flanged BF and BFHP, up to 50 bar HF, stainless process series up to 14 and 50 bar and high-pressure CHP and IHP up to 100, 250 and 420 bar.
- Size by the flow at your pressure. The nominal flow applies to the reference pressure; at lower pressure a larger filter is needed – the conversion is on each series page.
- Oil and water removal: captured oil and water drain from the coalescing element into the bowl, so the filter needs a condensate drain and a clogging indicator.
The order of all grades from coarse to sterile and all series are in the overview of industrial filtration according to ISO 8573-1; spare elements are listed with each series and in the overview of spare filter elements.
Product sorting
List of products
With a G 3/8" thread and a flow of 1,000 l/min at 7 bar, the AAFM-60 fine pre-filter traps fine solid particles larger than 0.1 µm, water and oil; residual oil is below 0.1...
With a G 3/8" thread and a flow of 500 l/min at 7 bar, the AAFM-30 fine pre-filter traps fine solid particles larger than 0.1 µm, water and oil; residual oil is below 0.1 mg/m³....
Omega Air AFM-170 fine pre-filter with a 2" thread and a flow of 16,667 l/min at 7 bar, up to 16 bar. The AF series has been replaced by the AAF series; the successor is the...
With a G 3/4" thread and a flow of 2,000 l/min at 7 bar, the AAFM-120 fine pre-filter traps fine solid particles larger than 0.1 µm, water and oil; residual oil is below 0.1...
Spare element AAFM-35V for fine pre-filters AAFM-35 and AAFM-60. Recommended replacement every 12 months or 4,000 operating hours.
Omega Air AFM-33 fine pre-filter with a 1" thread and a flow of 3,300 l/min at 7 bar, up to 16 bar. The AF series has been replaced by the AAF series; the successor is the...
With a G 2" thread and a flow of 16,667 l/min at 7 bar, the AAFM-1000 fine pre-filter traps fine solid particles larger than 0.1 µm, water and oil; residual oil is below 0.1...
A replacement element for FUTURA pre-filters with 0.3 µm filtration. Replace it when the clogging indicator shows a large pressure difference or the pressure after the filter...
A replacement element for FUTURA pre-filters with 0.3 µm filtration. Replace it when the clogging indicator shows a large pressure difference or the pressure after the filter...
With a G 1/4" thread and a flow of 417 l/min at 7 bar, the AAFM-25 fine pre-filter traps fine solid particles larger than 0.1 µm, water and oil; residual oil is below 0.1 mg/m³....
With a G 1 1/2" thread and a flow of 13,000 l/min at 7 bar, the AAFM-780 fine pre-filter traps fine solid particles larger than 0.1 µm, water and oil; residual oil is below 0.1...
A replacement element for FUTURA pre-filters with 0.3 µm filtration. Replace it when the clogging indicator shows a large pressure difference or the pressure after the filter...
A replacement element for FUTURA pre-filters with 0.3 µm filtration. Replace it when the clogging indicator shows a large pressure difference or the pressure after the filter...
A replacement element for FUTURA pre-filters with 0.3 µm filtration. Replace it when the clogging indicator shows a large pressure difference or the pressure after the filter...
A replacement element for FUTURA pre-filters with 0.3 µm filtration. Replace it when the clogging indicator shows a large pressure difference or the pressure after the filter...
Spare element AAFM-25V for fine pre-filters AAFM-25 and AAFM-30. Recommended replacement every 12 months or 4,000 operating hours.
Spare element AAFM-78V for fine pre-filter AAFM-78. Recommended replacement every 12 months or 4,000 operating hours.
Spare element AAFM-335V for fine pre-filter AAFM-335. Recommended replacement every 12 months or 4,000 operating hours.
A replacement element for FUTURA pre-filters with 0.3 µm filtration. Replace it when the clogging indicator shows a large pressure difference or the pressure after the filter...
A replacement element for FUTURA pre-filters with 0.3 µm filtration. Replace it when the clogging indicator shows a large pressure difference or the pressure after the filter...
Spare element AAFM-780V for fine pre-filter AAFM-780. Recommended replacement every 12 months or 4,000 operating hours.
Spare element AAFM-510V for fine pre-filter AAFM-510. Recommended replacement every 12 months or 4,000 operating hours.
Spare element PFM-010V for PF, HPF, WFIT, WFIF, WFIW, WHFIT and SPF fine pre-filters of size 010 — borosilicate microfibres. Replace it at least once every 12 months. The same...
With a G 2" thread and a flow of 25,000 l/min at 7 bar, the AAFM-1500 fine pre-filter traps fine solid particles larger than 0.1 µm, water and oil; residual oil is below 0.1...
With a G 2 1/2" thread and a flow of 28,000 l/min at 7 bar, the AAFM-1680 fine pre-filter traps fine solid particles larger than 0.1 µm, water and oil; residual oil is below 0.1...
With a G 1" thread and a flow of 5,583 l/min at 7 bar, the AAFM-335 fine pre-filter traps fine solid particles larger than 0.1 µm, water and oil; residual oil is below 0.1...
With a G 1 1/2" thread and a flow of 8,500 l/min at 7 bar, the AAFM-510 fine pre-filter traps fine solid particles larger than 0.1 µm, water and oil; residual oil is below 0.1...
Spare element AAFM-120V for fine pre-filter AAFM-120. Recommended replacement every 12 months or 4,000 operating hours.
With a G 3" thread and a flow of 36,000 l/min at 7 bar, the AAFM-2160 fine pre-filter traps fine solid particles larger than 0.1 µm, water and oil; residual oil is below 0.1...
Spare element BFM-0240V for BFM fine pre-filters of all sizes, diameter 90 mm, height 760 mm. Recommended replacement at least once a year or at a pressure drop of 350 mbar.
Spare element AAFM-1000V for fine pre-filter AAFM-1000. Recommended replacement every 12 months or 4,000 operating hours.
Spare element AAFM-1500V for fine pre-filters AAFM-1500 and AAFM-1680. Recommended replacement every 12 months or 4,000 operating hours.
Spare element AAFM-2760V for fine pre-filter AAFM-2760. Recommended replacement every 12 months or 4,000 operating hours.