Microfilter Hankison F03-B-HF – G 3/8", 983 l/min 0.01 microns · oil below 0.01 mg/m³ · class 1-x-1 · 16 bar

Code: F03-B-HF
Not rated Rating details
€212,17 –5 %
Hankison F03-B-HF
€212,17 –5 % €201,56 / pcs €166,58 excl. VAT Measure price:
Stock (1 pcs)
Delivery to:
17.11.2026
Delivery options
With a G 3/8" thread and a flow of 983 l/min, the Hankison NGF F03-B-HF microfilter traps solid and liquid particles larger than 0.01 µm and removes over 99.9% of oil aerosol; residual oil is below 0.01 mg/m³. Working pressure up to 16 bar; supplied with a pressure drop indicator on the head.

Detailed information

Free shipping
Free shipping
For purchases over 5,000 CZK
We guarantee
We guarantee
Extended warranty and service
Discount voucher
Discount voucher
For every purchase
Return of goods within 14 days
Return of goods within 14 days
Completely at our expense

Product detailed description

The Hankison NGF F03-B-HF coalescing microfilter traps solid and liquid particles larger than 0.01 µm and removes over 99.9% of oil aerosol; residual oil is below 0.01 mg/m³. It has a G 3/8" thread, a flow of 983 l/min (59 Nm³/h) at 7 bar and a working pressure of up to 16 bar.

It belongs to the range of Hankison NGF filters: the housing is the same for all five stages, and the stage is determined by the element with its coloured end cap.

Specifications

ParameterValue
ConnectionG 3/8" (female thread)
Flow at 7 bar983 l/min (59 Nm³/h)
Working pressure16 bar
Inlet air temperature+2 to +66 °C
Particle retention0.01 µm
Residual oil< 0.01 mg/m³
ISO 8573-1 class1-x-1
Particle removal efficiency99.999+ %
Oil removal efficiency99.9+ %
Maximum inlet liquid load1 g/m³
Pressure drop of a new element (dry / wet)40 mbar / 120 mbar
Element replacementafter 3,000 operating hours, within 12 months at the latest, or at a pressure drop of 400 mbar
Element end cap colourgreen
Spare elementHF-03
Clogging indicationpressure drop indicator on the head
Condensate drainautomatic float drain
Housingdie-cast aluminium, chromated, powder-coated
Width A113.6 mm
Height B205.5 mm
Connection axis to bottom edge C171.4 mm
Clearance below the filter D102 mm
Weight0.8 kg

Housing and dimensions

Drawing of an NGF filter with dimensions A, B, C and D
A width, B height, C from the connection axis to the bottom edge, D clearance below the filter for removing the element.

The housing is die-cast aluminium, chromated and protected by a polyester epoxy powder coating. The inlet and outlet are shaped as flanges with a female thread; the bowl has internal ribs along which the condensate runs down.

Dimensions according to the manufacturer: width A 113.6 mm, height B 205.5 mm, connection axis to bottom edge C 171.4 mm, and a clearance D of 102 mm is needed below the filter so that the bowl can be removed. Weight 0.8 kg.

Standard equipment

Cutaway of a Hankison NGF filter with the element inside
NGF filter cutaway (illustrative): the element hangs in the filter head, with the bowl and condensate drain below it.

The filter is supplied with the HF-03 element, a pressure drop indicator on the head and an automatic float condensate drain.

The indicator on the head monitors the pressure drop of the element: as the element clogs, the pressure drop rises. However, also replace the element by time, even if the indicator does not yet signal it.

Flow by pressure

The flow applies to a pressure of 7 bar and a temperature of +20 °C. At a different pressure, it changes according to the correction factor; this filter works up to 16 bar:

Pressure (bar)4567810121416
Flow (l/min)6197378659831,1101,3561,6211,8382,093

When to use it

It suits the end of the air line before the point of use, as an oil coalescing filter and as a pre-filter for a membrane or adsorption dryer.

Where to place it

Filtration stages in the direction of flow, with stage HF highlighted
In the direction of flow: 1 basic SF, 2 dust PF, 3 microfilter HF, 4 microfilter UF, 5 activated carbon CF. HF is highlighted.

It goes after the PF dust filter, which protects it, and before CF activated carbon or a dryer.

Element and maintenance

Filter element HF-03
Element end cap colour: green.

Replace the HF-03 element (green end cap) after 3,000 operating hours, within 12 months at the latest, or at a pressure drop of 400 mbar.

Filter medium

Air flow through an NGF filter and a Venturi-Wave element
Air flow through the housing and element (illustrative).

The element has the patented Venturi-Wave shape, through which air enters the element without turbulence, and a deep pleated filter medium with a large area — air passes through it with a lower pressure drop.

You will find other sizes among the filters of the same stage, and spare elements in the NGF accessories.

Additional parameters

Category: Hankison NGF HF microfilters for particles and oil
Pressure: 16 bar
Connecting: 3/8"
Dimensions: 113 × 205 mm
Certification: ISO 8573-1 (IUTA)
Filtration: 0.01 µm
Filter insert: HF-03
Material: Aluminium
Condensate discharge: Automatic
Working temperature: +2 / +66 °C
Flow: 983 l/min
Product type: Complete filter
Residual oil: <0,01 mg/m³
Quality class - oils: 1
Quality class - solid impurities: 1
Filtration stage: Microfilter 0.01 µm
Connection type: Female thread
In stock: External warehouse

Product rating

Be the first who will post an article to this item!

Do not fill out this field

How would you rate this product? Choose 1 to 5 stars, where 1 is the worst and 5 is the best rating.

Security check

By submitting your review you agree to the privacy policy

Hankison is an American manufacturer of compressed air dryers and filters with a history going back to 1948. We offer its NGF filters in five filtration stages, spare elements for them and HDI refrigeration dryers.

NGF filters use the same housing for all stages, only the element differs — you can recognise the stage by the colour of the end cap. Stages SF to UF come with a pressure drop indicator and a condensate drain. HDI dryers dry the air to a pressure dew point of +3 °C.

Hankison HDI-600 and HDI-12 refrigeration dryers and Hankison NGF PF and HF filters with their elementsPurity to ISO 8573-1
since 1948in compressed air treatment
5 stagesof NGF filtration, from 3 µm to activated carbon
+3 °Cpressure dew point of HDI dryers
up to 16 barpressure of NGF filters and HDI dryers

NGF filters and HDI dryers

Hankison NGF filter elements with orange, white, green, yellow and black end caps

NGF filters — the whole range

Five stages in one housing. The stages are installed one after another from coarse to fine, each protecting the next.

  • 14 sizes, G 1/4″ to 3″
  • flow from 566 to 42,483 l/min
  • up to 16 bar, F13 to F17 up to 11 bar
View the NGF range
Hankison NGF SF basic filter and element with an orange end cap

SF basic filter

At the start of filtration, where there is a lot of water. A liquid separator and 3 µm filter removes more than 99 % of liquid condensate.

  • residual oil below 5 mg/m³
  • handles up to 25 g of liquid per m³ of air
  • orange element end cap
View SF filters
Hankison NGF PF dust filter and element with a white end cap

PF dust filter and pre-filter

Before a microfilter and after a desiccant dryer. A double depth layer captures particles from 1 µm with 99.999 % efficiency.

  • residual oil below 2 mg/m³
  • protects the HF and UF microfilter elements
  • white element end cap
View PF filters
Hankison NGF HF microfilter and element with a green end cap

HF microfilter

Air free of oil aerosol. A coalescing filter that captures particles from 0.01 µm and removes more than 99.9 % of oil.

  • residual oil below 0.01 mg/m³
  • class 1-x-1 according to ISO 8573-1
  • green element end cap
View HF microfilters
Hankison NGF UF ultra-fine microfilter and element with a yellow end cap

UF ultra-fine microfilter

For painting and sensitive instruments. The same 0.01 µm rating as HF, but ten times less oil in the air.

  • residual oil below 0.001 mg/m³
  • needs a PF dust filter upstream
  • yellow element end cap
View UF microfilters
Hankison NGF CF activated carbon filter and element with a black end cap

CF activated carbon filter

Oil vapours, odours and tastes. Two layers of activated carbon for air that comes into contact with food or medicines.

  • oil vapour below 0.004 mg/m³
  • always after an HF or UF microfilter
  • element replaced after 1,000 hours
View CF filters
Hankison HF-08 spare element with a green end cap

NGF spare elements

For all five stages and 14 sizes. The element code is the stage plus the filter size, such as HF-06 for the F06-B-HF filter.

  • replace at a pressure drop of 400 mbar
  • after 12 months at the latest
  • stage shown by the end cap colour
View elements
Hankison HDI-72 refrigeration dryer for compressed air

HDI refrigeration dryers

Dry air with a +3 °C dew point. A patented aluminium heat exchanger cools the air in two stages and saves energy.

  • 17 sizes, 200 to 21,667 l/min
  • working pressure up to 16 bar
  • 230 V up to HDI-600, larger sizes 400 V
View HDI dryers

Not sure how large a dryer you need? The calculator in the dryer category selects one based on the application, compressor output, pressure and temperatures.

Choose a dryer

Hankison filters and dryers side by side

What each product removes from the air
ProductRemovesRating / dew pointResidual oilISO 8573-1 class
SF basic filterliquid water and solid particles3 µmbelow 5 mg/m³3-x-4
PF dust filtersolid particles and liquid1 µmbelow 2 mg/m³2-x-4
HF microfilteroil aerosol and fine particles0.01 µmbelow 0.01 mg/m³1-x-1
UF ultra-fine microfilteroil aerosol and fine particles0.01 µmbelow 0.001 mg/m³1-x-1
CF activated carbon filteroil vapours, odours and tastes0.01 µmbelow 0.004 mg/m³ (vapour)1-x-1
HDI dryerwater vapourdew point +3 °C–x-4-x

The ISO 8573-1 class is written as solid particles – water – oil; x means the product does not deal with that component.

How to set up air treatment

1. Pre-filter before the dryer

An HDI refrigeration dryer needs a pre-filter rated 10 µm or finer upstream — the manufacturer requires it. Where there is a lot of water in the system, an SF basic filter does the job.

2. Dryer to match the compressor

The dryer must handle the full output of the compressor. Choose the HDI size whose flow is at least equal to the compressor output.

3. Filters after the dryer

A refrigeration dryer is followed by a PF dust filter and an HF microfilter, or a UF ultra-fine microfilter for painting and sensitive instruments. Put CF activated carbon at the very end.

4. Replace elements on time

SF and PF after 6,000 operating hours, HF and UF after 3,000, CF after 1,000 — always after 12 months at the latest, or earlier at a pressure drop of 400 mbar.

Frequently asked questions

What is the difference between the HF and UF microfilters?
Both capture particles from 0.01 µm. The UF ultra-fine microfilter, however, leaves ten times less oil in the air: below 0.001 mg/m³ compared with 0.01 mg/m³ for HF.
Why does a PF dust filter go before the microfilter?
The PF dust filter captures solid particles and liquid before they reach the fine microfilter element. The HF or UF element then lasts longer.
How do I recognise the element stage?
By the end cap colour: orange SF, white PF, green HF, yellow UF and black CF. Each filter size has its own element, and the element code ends with the size number.
Does an NGF filter also remove moisture?
No. Filters only capture water that has already condensed. Water vapour is removed by a dryer — an HDI refrigeration dryer dries the air to a pressure dew point of +3 °C.
Is an HDI dryer suitable for an unheated hall?
Only where the temperature does not drop below zero. A +3 °C dew point means water will not condense until the temperature falls below +3 °C. For systems exposed to frost you need a desiccant dryer with a dew point below 0 °C.

The HDI dryers come with the manufacturer’s brochure in English for download, and sizes HDI-12 to HDI-950 also with an English manual. Hankison® is a registered trademark of the manufacturer Hankison.