Hankison NGF compressed air filters with clogging indication

NGF filters from the American manufacturer Hankison remove liquid, solid particles, oil aerosol, oil vapours and odours from compressed air. Five filtration stages cover everything from condensate separation to activated carbon; element performance is tested according to ISO 12500, and air purity is stated according to ISO 8573-1.
The range has 14 sizes, F02 to F17, with G 1/4" to G 3" threads and flows of 566 to 42,483 l/min. The filter is supplied with an element, a pressure drop indicator on the head and a condensate drain. The range is part of the industrial compressed air filters.
Filtration stages and elements
Each tile leads to a stage with a table of sizes, elements and flows. You can recognise the stage by the colour of the element end cap.
Filtration stages at a glance
Data from the manufacturer Hankison according to ISO 12500 (inlet oil 10 mg/m³). The ISO 8573-1 class is written as solid particles – water – oil.
| NGF filtration stages | |||||||
|---|---|---|---|---|---|---|---|
| Stage | Filtration rating | Residual oil | ISO 8573-1 class | Particle removal | Oil removal | Pressure drop dry / wet | Element end cap |
| SF basic filter 3 µm | 3 µm | < 5 mg/m³ | 3-x-5 | – | 50 % | 60 mbar / 70 mbar | orange |
| PF dust filter 1 µm | 1 µm | < 2 mg/m³ | 2-x-4 | 99.999+ % | 80 % | 40 mbar / 100 mbar | white |
| HF microfilter 0.01 µm | 0.01 µm | < 0.01 mg/m³ | 1-x-1 | 99.999+ % | 99.9+ % | 40 mbar / 120 mbar | green |
| UF ultra-fine microfilter 0.01 µm | 0.01 µm | < 0.001 mg/m³ | 1-x-1 | 99.999+ % | 99.9+ % | 60 mbar / 140 mbar | yellow |
| CF activated carbon | 0.01 µm | < 0.004 mg/m³ (as vapour) | 1-x-1 | 99.999+ % | – | 70 mbar / – | black |
Residual oil for CF is in the form of vapour. Solid particle class 1 for CF activated carbon applies when an HF or UF microfilter is installed before it.
#showmore#
How to read the ISO 8573-1 purity class
The ISO 8573-1 standard describes the purity of compressed air with three numbers: solid particles, water and oil. The lower the number, the cleaner the air. The letter x means that the filter does not determine that component. The ISO 12500 standard specifies how manufacturers test filters: part 1 oil aerosol removal, part 2 oil vapours and part 3 particle removal.
HF and UF microfilters with class 1-x-1 thus ensure the highest purity for particles and oil, but they do not deal with humidity. Filters only trap water that has already condensed. Water vapour is removed by a compressed air dryer.
How to put the filtration together

The stages are arranged from coarse to fine in the direction of flow: SF basic filter, PF dust filter, HF microfilter, UF ultra-fine microfilter and finally CF activated carbon. Each stage protects the finer stages after it, so their elements last longer.
The PF dust filter goes before the HF or UF microfilter as a pre-filter. CF activated carbon always goes after a microfilter — liquid oil must not reach it.
Filters can be joined directly one after another using a connection kit with a seal and a clamp, without piping between them. The HF microfilter also serves as a pre-filter for membrane and adsorption dryers, while the PF dust filter after an adsorption dryer traps dust from the adsorbent.
Typical configurations
Workshop and blow-off air: an SF basic filter where there is a lot of condensate, followed by a PF dust filter.
Oil-free air for tools and instruments: a PF dust filter followed by an HF microfilter.
Painting, pneumatic instruments, electronics: a PF dust filter and a UF ultra-fine microfilter, with an HF microfilter between them for high requirements.
Food, pharmaceuticals, process and analytical air: a PF dust filter, an HF or UF microfilter and CF activated carbon at the end.
Filter sizes

The size determines the thread, the flow and the element. All stages of the same size have the same housing, thread and flow; only the element differs.
The smallest filter, F02, is 205.5 mm tall and weighs 0.8 kg; the largest, F17, is 1,085.1 mm tall and weighs 12.6 kg. Sizes F02 to F12 work up to 16 bar, F13 to F17 up to 11 bar.
| NGF filter sizes | |||||||
|---|---|---|---|---|---|---|---|
| Size | Thread | Nm³/h | l/min | Pressure up to | Width A | Height B | Weight |
| F02 | G 1/4" | 34 | 566 | 16 bar | 113.6 mm | 205.5 mm | 0.8 kg |
| F03 | G 3/8" | 59 | 983 | 16 bar | 113.6 mm | 205.5 mm | 0.8 kg |
| F04 | G 1/2" | 85 | 1,416 | 16 bar | 113.6 mm | 252 mm | 0.9 kg |
| F06 | G 3/4" | 127 | 2,116 | 16 bar | 132 mm | 262.1 mm | 1.4 kg |
| F07 | G 3/4" | 175 | 2,916 | 16 bar | 132 mm | 262.1 mm | 1.4 kg |
| F08 | G 1" | 267 | 4,450 | 16 bar | 132 mm | 326.1 mm | 1.6 kg |
| F10 | G 1 1/2" | 437 | 7,283 | 16 bar | 200 mm | 336.7 mm | 3.8 kg |
| F11 | G 1 1/2" | 612 | 10,200 | 16 bar | 200 mm | 433.7 mm | 4.5 kg |
| F12 | G 2" | 681 | 11,350 | 16 bar | 200 mm | 566 mm | 5.3 kg |
| F13 | G 2 1/2" | 965 | 16,083 | 11 bar | 230.8 mm | 634.4 mm | 8.4 kg |
| F14 | G 2 1/2" | 1,317 | 21,950 | 11 bar | 230.8 mm | 634.4 mm | 8.4 kg |
| F15 | G 2 1/2" | 2,039 | 33,983 | 11 bar | 230.8 mm | 634.4 mm | 8.4 kg |
| F16 | G 3" | 2,039 | 33,983 | 11 bar | 230.8 mm | 817.1 mm | 12.6 kg |
| F17 | G 3" | 2,549 | 42,483 | 11 bar | 230.8 mm | 1,085.1 mm | 12.6 kg |
The manufacturer states the flows for a pressure of 7 bar and a temperature of +20 °C. You will find the other dimensions on the product page of each filter.
Flow at a different pressure

At a pressure other than 7 bar, multiply the flow by the correction factor: at a lower pressure the filter passes less air, at a higher pressure more.
Example: the F06-B-HF has a flow of 2,116 l/min at 7 bar, 2,116 × 1.38 = 2,920 l/min at 10 bar and only 1,587 l/min at 5 bar.
| Flow correction factor by pressure | |||||||||
|---|---|---|---|---|---|---|---|---|---|
| Pressure (bar) | 4 | 5 | 6 | 7 | 8 | 10 | 12 | 14 | 16 |
| Factor | 0.63 | 0.75 | 0.88 | 1.00 | 1.13 | 1.38 | 1.65 | 1.87 | 2.13 |
Housing and dimensions

The housing is die-cast aluminium, chromated and protected by a polyester epoxy powder coating. The inlet and outlet are shaped as flanges with a female thread, and the bowl has internal ribs along which the condensate runs down to the drain.
The element has the patented Venturi-Wave shape, through which air enters the element without turbulence, and a deep pleated filter medium. Leave clearance D below the filter so that the bowl can be removed and the element replaced.
Pleated filter medium

The element medium is pleated into deep folds, so for the same size it has a much larger area than a flat layer. Air passes through it more slowly and with a lower pressure drop.
Filter cutaway

The element hangs in the filter head. Air enters the element through the shaped end cap, passes through the pleated medium, and the separated liquid runs down the ribs of the bowl to the drain.
Air flow path

The patented Venturi-Wave element shape guides the air into the element without turbulence. Optimised flow paths in the head and element reduce the pressure drop and thus the energy consumption of the compressor.
Equipment by size
The filter is supplied with an element, a pressure drop indicator on the head and a condensate drain:
| Equipment by size | ||
|---|---|---|
| Sizes | Clogging indication | Condensate drain |
| F02 – F07 (SF, PF, HF, UF) | pressure drop indicator on the head | automatic float drain |
| F08 – F12 (SF, PF, HF, UF) | differential pressure gauge on the head | automatic float drain |
| F13 – F17 (SF, PF, HF, UF) | differential pressure gauge on the head | level-controlled electronic drain |
| F02 – F17 (CF) | no indication (activated carbon is replaced by time) | manual valve (ball valve) |
The indicator and the gauge show the pressure drop of the element. The CF activated carbon filter does not need one — its element is replaced by time.
Maintenance
Elements are replaced according to operating hours, at least once every 12 months, or earlier at a pressure drop of 400 mbar. You will find all of them among the NGF spare elements.
| Element replacement | ||
|---|---|---|
| Stage | At the latest | Or at a pressure drop of |
| SF basic filter 3 µm | 6,000 h / 12 months | 400 mbar |
| PF dust filter 1 µm | 6,000 h / 12 months | 400 mbar |
| HF microfilter 0.01 µm | 3,000 h / 12 months | 400 mbar |
| UF ultra-fine microfilter 0.01 µm | 3,000 h / 12 months | 400 mbar |
| CF activated carbon | 1,000 h / 12 months | – |
Other filters
For pressures up to 16 bar, there are also Omega Air AAF threaded filters, for large flows BF flanged filters and for pressures up to 50 bar HF high-pressure filters. You will find the whole range among the industrial compressed air filters.
Ventilek’s tip
A microfilter needs a pre-filter. Install a PF dust filter before the HF or UF microfilter. It traps particles and liquid, and the microfilter element after it then only deals with the finest contaminants.
- Which filtration stage do I need?
- For condensate and coarse contaminants the SF basic filter, for dust and as a pre-filter the PF, for oil aerosol the HF microfilter (oil below 0.01 mg/m³) or UF (below 0.001 mg/m³), for oil vapours and odours CF activated carbon.
- Is a clogging indicator part of the filter?
- Yes. Sizes F02 to F07 have a pressure drop indicator, F08 to F17 a differential pressure gauge. The CF activated carbon filter has no indicator.
- Is a condensate drain included?
- Yes. F02 to F12 have a float drain, F13 to F17 a level-controlled electronic drain. The CF filter has a manual valve.
- How do I choose the size?
- By the flow at your pressure. The flows apply to 7 bar; at a different pressure, multiply them by the correction factor.
- How often should the elements be replaced?
- SF and PF after 6,000 operating hours, HF and UF after 3,000, CF after 1,000 — always within 12 months at the latest, or earlier at a pressure drop of 400 mbar.
- What pressure and temperature can the filters withstand?
- Sizes F02 to F12 up to 16 bar, F13 to F17 up to 11 bar. Inlet air at most +66 °C.
Bestsellers
Product sorting
List of products
With a G 3/8" thread and a flow of 983 l/min, the Hankison NGF F03-B-HF microfilter traps solid and liquid particles larger than 0.01 µm and removes over 99.9% of oil aerosol;...
Spare element SF-04 with a orange end cap for the Hankison F04-B-SF basic filter. Replacement: 6,000 h / 12 months.
Spare element HF-03 with a green end cap for the Hankison F03-B-HF microfilter. Replacement: 3,000 h / 12 months.
With a G 1/2" thread and a flow of 1,416 l/min, the Hankison NGF F04-B-HF microfilter traps solid and liquid particles larger than 0.01 µm and removes over 99.9% of oil aerosol;...
With a G 3/8" thread and a flow of 983 l/min, the Hankison NGF F03-B-SF basic filter removes over 99% of liquid condensate and traps solid particles larger than 3 µm; residual...
With a G 3/8" thread and a flow of 983 l/min, the Hankison NGF F03-B-PF dust filter traps solid particles larger than 1 µm with an efficiency of 99.999%, as well as large...
Spare element SF-02 with a orange end cap for the Hankison F02-B-SF basic filter. Replacement: 6,000 h / 12 months.
With a G 1/4" thread and a flow of 566 l/min, the Hankison NGF F02-B-SF basic filter removes over 99% of liquid condensate and traps solid particles larger than 3 µm; residual...
Spare element SF-03 with a orange end cap for the Hankison F03-B-SF basic filter. Replacement: 6,000 h / 12 months.
Spare element SF-07 with a orange end cap for the Hankison F07-B-SF basic filter. Replacement: 6,000 h / 12 months.
Spare element SF-08 with a orange end cap for the Hankison F08-B-SF basic filter. Replacement: 6,000 h / 12 months.
With a G 1/4" thread and a flow of 566 l/min, the Hankison NGF F02-B-HF microfilter traps solid and liquid particles larger than 0.01 µm and removes over 99.9% of oil aerosol;...
With a G 1/2" thread and a flow of 1,416 l/min, the Hankison NGF F04-B-SF basic filter removes over 99% of liquid condensate and traps solid particles larger than 3 µm; residual...
With a G 3/4" thread and a flow of 2,116 l/min, the Hankison NGF F06-B-SF basic filter removes over 99% of liquid condensate and traps solid particles larger than 3 µm; residual...
With a G 3/4" thread and a flow of 2,916 l/min, the Hankison NGF F07-B-SF basic filter removes over 99% of liquid condensate and traps solid particles larger than 3 µm; residual...
With a G 1" thread and a flow of 4,450 l/min, the Hankison NGF F08-B-SF basic filter removes over 99% of liquid condensate and traps solid particles larger than 3 µm; residual...
Spare element SF-10 with a orange end cap for the Hankison F10-B-SF basic filter. Replacement: 6,000 h / 12 months.
With a G 1/2" thread and a flow of 1,416 l/min, the Hankison NGF F04-B-PF dust filter traps solid particles larger than 1 µm with an efficiency of 99.999%, as well as large...
Spare element SF-06 with a orange end cap for the Hankison F06-B-SF basic filter. Replacement: 6,000 h / 12 months.
Spare element UF-04 with a yellow end cap for the Hankison F04-B-UF ultra-fine microfilter. Replacement: 3,000 h / 12 months.
Spare element HF-08 with a green end cap for the Hankison F08-B-HF microfilter. Replacement: 3,000 h / 12 months.
Spare element PF-03 with a white end cap for the Hankison F03-B-PF dust filter. Replacement: 6,000 h / 12 months.
Spare element PF-02 with a white end cap for the Hankison F02-B-PF dust filter. Replacement: 6,000 h / 12 months.
Spare element PF-08 with a white end cap for the Hankison F08-B-PF dust filter. Replacement: 6,000 h / 12 months.
Spare element HF-04 with a green end cap for the Hankison F04-B-HF microfilter. Replacement: 3,000 h / 12 months.
Spare element HF-02 with a green end cap for the Hankison F02-B-HF microfilter. Replacement: 3,000 h / 12 months.
Spare element PF-04 with a white end cap for the Hankison F04-B-PF dust filter. Replacement: 6,000 h / 12 months.
Spare element HF-06 with a green end cap for the Hankison F06-B-HF microfilter. Replacement: 3,000 h / 12 months.
Spare element HF-07 with a green end cap for the Hankison F07-B-HF microfilter. Replacement: 3,000 h / 12 months.
Spare element CF-06 with a black end cap for the Hankison F06-B-CF activated carbon filter. Replacement: 1,000 h / 12 months.
Spare element PF-06 with a white end cap for the Hankison F06-B-PF dust filter. Replacement: 6,000 h / 12 months.
Spare element PF-07 with a white end cap for the Hankison F07-B-PF dust filter. Replacement: 6,000 h / 12 months.
With a G 3/4" thread and a flow of 2,916 l/min, the Hankison NGF F07-B-HF microfilter traps solid and liquid particles larger than 0.01 µm and removes over 99.9% of oil aerosol;...
Spare element UF-10 with a yellow end cap for the Hankison F10-B-UF ultra-fine microfilter. Replacement: 3,000 h / 12 months.
With a G 3/4" thread and a flow of 2,116 l/min, the Hankison NGF F06-B-PF dust filter traps solid particles larger than 1 µm with an efficiency of 99.999%, as well as large...
Spare element HF-10 with a green end cap for the Hankison F10-B-HF microfilter. Replacement: 3,000 h / 12 months.
Spare element HF-11 with a green end cap for the Hankison F11-B-HF microfilter. Replacement: 3,000 h / 12 months.
With a G 3/4" thread and a flow of 2,116 l/min, the Hankison NGF F06-B-HF microfilter traps solid and liquid particles larger than 0.01 µm and removes over 99.9% of oil aerosol;...
With a G 1" thread and a flow of 4,450 l/min, the Hankison NGF F08-B-HF microfilter traps solid and liquid particles larger than 0.01 µm and removes over 99.9% of oil aerosol;...
With a G 3/4" thread and a flow of 2,916 l/min, the Hankison NGF F07-B-PF dust filter traps solid particles larger than 1 µm with an efficiency of 99.999%, as well as large...