PPA filtration system for painting and paint shops up to 16 bar

The PPA filtration system from the Slovenian manufacturer Omega Air cleans compressed air of solid and liquid contaminants and partly also of gaseous ones. It protects the connected air equipment and supplies clean air for painting and other work.
The filters, a pressure regulator with gauge and 2 quick couplings form one unit, which is mounted on the wall. The manufacturer designs it for paint shops, the chemical and petrochemical industries and general industry. It is part of the range of industrial compressed air filters.
Choose a unit
The unit is chosen according to whether there is a dryer in the compressed air network and the air quality required. Symbols below the filters: CKL separator, M fine pre-filter 0.1 µm, S microfilter 0.01 µm, A activated carbon. The air flows through them from the left.
Units compared
According to the manufacturer’s technical data sheet. After the filters, each unit has a pressure regulator with gauge and 2 quick couplings.
#showmore#
With or without a dryer
The unit filters the air but does not dry it. Water is removed from the air by a compressed air dryer in the network. If there is one in the network, a unit without C is enough: the PPA-207 with a fine pre-filter and a microfilter, or the PPA-307, which also has activated carbon.
Without a dryer, the air entering the unit contains water and more contaminants. That is why the C versions start with a CKL-PP separator with a sintered filter, which separates liquid and traps particles larger than 5 µm. After it, the PPA-207C cleans the air with a fine pre-filter to 0.1 µm, while the PPA-307C adds a 0.01 µm microfilter.
Activated carbon traps oil vapours and odours that pass through the microfilter. The manufacturer only puts it in a unit for a network with a dryer.
Technical data
| Data common to all units | |
|---|---|
| Parameter | Value |
| Connection | G 1/2" |
| Flow | 78 Nm³/h (1,300 l/min) at 7 bar and 20 °C |
| Working pressure | 0 to 16 bar |
| Working temperature | +1.5 to +65 °C |
| Pressure regulator | with gauge, scale 0 to 10 bar |
| Outlets | 2 quick couplings |
| Length A | 440 mm with 2 filters, 530 mm with 3 filters |
| Depth B × height C | 135 × 290 mm |
| Space below the filters (D) | 80 mm |
| Filter housings | aluminium, anodised, powder coated |
| Seals | NBR |
| Colour | dark grey RAL 7021 |
| Mounting | on the wall or on the PPA-MS portable stand |
Dimensions and mounting

Length A is 440 mm for units with 2 filters and 530 mm for units with 3 filters. Depth B of 135 mm and height C of 290 mm are the same for all of them.
Leave free space D of at least 80 mm below the filters for replacing the elements.
The unit is mounted on the wall. For work in different places, there is the PPA-MS portable stand.
Flow by pressure

The nominal flow of 78 Nm³/h, i.e. 1,300 l/min, applies at 7 bar and 20 °C. At a different pressure, multiply it by the correction factor from the table.
Example: at 6 bar the factor is 0.88 and the unit passes 68.6 Nm³/h. At 10 bar it is 107.6 Nm³/h.
| Flow by working pressure | |||
|---|---|---|---|
| Working pressure (bar) | Correction factor | Flow (Nm³/h) | Flow (l/min) |
| 2 | 0.38 | 29.6 | 493 |
| 3 | 0.50 | 39 | 650 |
| 4 | 0.63 | 49.1 | 818 |
| 5 | 0.75 | 58.5 | 975 |
| 6 | 0.88 | 68.6 | 1,143 |
| 7 | 1.00 | 78 | 1,300 |
| 8 | 1.13 | 88.1 | 1,468 |
| 9 | 1.25 | 97.5 | 1,625 |
| 10 | 1.38 | 107.6 | 1,793 |
| 11 | 1.50 | 117 | 1,950 |
| 12 | 1.63 | 127.1 | 2,118 |
| 13 | 1.75 | 136.5 | 2,275 |
| 14 | 1.88 | 146.6 | 2,443 |
| 15 | 2.00 | 156 | 2,600 |
| 16 | 2.13 | 166.1 | 2,768 |
Maintenance
Replace the filter elements at least once every 6 months, unless the instructions for the specific element state otherwise. Once a year, check that the filter housings are not visibly damaged.
You set the outlet pressure with the regulator. The gauge with a scale of 0 to 10 bar shows it.
Portable stand

The PPA-MS portable stand holds the PPA unit instead of the wall. Using the handle, you carry it to wherever the work is being done.
The filtration unit is ordered separately.
Other filters
Air for breathing apparatus and masks is cleaned by B-AIR breathable air filters. You will find separate compressed air filters among the Omega Air industrial filters and AAFS silicone-free filters, and parts and tools in the accessories for filters and service.
- What is the difference between the versions with and without C?
- The C versions (PPA-207C and PPA-307C) are for a network without a dryer and start with a CKL-PP separator. The versions without C (PPA-207 and PPA-307) assume a dryer in the network and have no separator.
- Does the filtration system have a dryer?
- No. The unit filters the air; water is removed from it by a dryer in the network. Without a dryer, choose a C version.
- How much air does the unit pass?
- 78 Nm³/h, i.e. 1,300 l/min, at 7 bar and 20 °C. At a different pressure, multiply the flow by the correction factor from the table; at 6 bar it is 0.88.
- How often should the elements be replaced?
- The manufacturer recommends at least once every 6 months, unless the instructions for the specific element state otherwise.
- Can the unit be moved?
- It is designed for wall mounting. For work in different places, there is the PPA-MS portable stand, to which the unit is attached.
Bestsellers
Product sorting
List of products
Portable stand for the PPA filtration system: the unit is attached to it instead of the wall, and the handle lets you carry it to where the work is done. The unit is ordered...