Spare filter elements for IHP stainless steel high-pressure filters

IHP spare elements fit the IHP1, IHP2 and IHP4 stainless steel high-pressure filters. The element determines the filtration stage — from the N25 stainless steel mesh to activated carbon A.
One element fits the filters for all three pressures of the same size and stage: for example IHPS-007V fits the IHP1S-007, IHP2S-007, IHP4S-007. The elements are made for 8 filter sizes with G 1/4" to G 2" threads.
Element stages

IHPN25 coarse filters
The 25 µm stainless steel mesh traps coarse contaminants.

IHPN5 basic filters
The 5 µm stainless steel mesh traps solid contaminants.

IHPR dust filters
1 µm element for dust and liquid water, class 3.

IHPM fine pre-filters
0.1 µm fine pre-filter, residual oil below 0.1 mg/m³, class 2-x-2.

IHPS microfilters
0.01 µm microfilter, residual oil below 0.01 mg/m³, class 1-x-1.

IHPA activated carbon filters
Oil vapours, hydrocarbons and odours, residual oil below 0.005 mg/m³.
Elements at a glance
| IHP elements at a glance | |||||
|---|---|---|---|---|---|
| Stage | Filtration rating | Material | Design | Replacement | Temperature up to |
| N25 – coarse filter | 25 µm | stainless steel mesh 1.4301 | wrapped | at least once a year | +65 °C |
| N5 – basic filter | 5 µm | stainless steel mesh 1.4301 | wrapped | at least once a year | +65 °C |
| R – dust filter | 1 µm | – | – | 350 mbar, at least once a year | +65 °C |
| M – fine pre-filter | 0.1 µm | borosilicate microfibres | pleated | 350 mbar, at least once a year | +65 °C |
| S – microfilter | 0.01 µm | borosilicate microfibres | pleated | 350 mbar, at least once a year | +65 °C |
| A – activated carbon filter | – | activated carbon | wrapped | every 6 months | +45 °C |
The elements are replaced according to the pressure drop or by time; the sintered element B is cleaned. Activated carbon works up to +45 °C.
Elements by size and stage
Each row is a filter size with its thread, each column a stage. The code leads to the product page of the element.
| IHP spare elements by size and stage | ||||||
|---|---|---|---|---|---|---|
| Size (thread) | N25 | N5 | R | M | S | A |
| 003 (G 1/4") | IHPN25-003V | IHPN5-003V | IHPR-003V | IHPM-003V | IHPS-003V | IHPA-003V |
| 005 (G 3/8") | IHPN25-005V | IHPN5-005V | IHPR-005V | IHPM-005V | IHPS-005V | IHPA-005V |
| 007 (G 1/2") | IHPN25-007V | IHPN5-007V | IHPR-007V | IHPM-007V | IHPS-007V | IHPA-007V |
| 010 (G 3/4") | IHPN25-010V | IHPN5-010V | IHPR-010V | IHPM-010V | IHPS-010V | IHPA-010V |
| 018 (G 1") | IHPN25-018V | IHPN5-018V | IHPR-018V | IHPM-018V | IHPS-018V | IHPA-018V |
| 030 (G 1 1/4") | IHPN25-030V | IHPN5-030V | IHPR-030V | IHPM-030V | IHPS-030V | IHPA-030V |
| 047 (G 1 1/2") | IHPN25-047V | IHPN5-047V | IHPR-047V | IHPM-047V | IHPS-047V | IHPA-047V |
| 094 (G 2") | IHPN25-094V | IHPN5-094V | IHPR-094V | IHPM-094V | IHPS-094V | IHPA-094V |
#showmore#
How to find the right element
The element code consists of the housing type, the stage and the size, with the letter V at the end. The IHP1S-007 filter therefore needs the IHPS-007V element: type IHP, stage S, size 007.
The number after the filter type (1, 2 or 4) only determines the working pressure of the housing. The element is the same for all three pressures.
Order of stages

The stages are arranged from coarse to fine in the direction of flow. Each stage protects the finer stages after it, so their elements last longer.
The fine pre-filter M goes before the microfilter S. An S microfilter always goes before activated carbon A — only with it does solid particle class 1 apply.
Element replacement
Elements R, M and S are replaced at a pressure drop of 350 mbar, at least once every 12 months, the N25 and N5 stainless steel meshes at least once every 12 months. The activated carbon element is replaced every 6 months.
Depressurise the filter before replacing the element. Once a year, also check the housing for visible damage.
Filters
The elements fit the IHP1 stainless steel filters up to 100 bar, IHP2 stainless steel filters up to 250 bar, IHP4 stainless steel filters up to 420 bar. You will find more elements among the Omega Air spare filter elements.
- Does the element fit a filter for a different pressure?
- Yes. A IHP element of the same stage and size fits the IHP1, IHP2, IHP4 filters.
- How do I know which element I need?
- By the filter code: type, stage and size. The IHP1S-007 filter takes the IHPS-007V element.
- How often should the elements be replaced?
- R, M and S at a pressure drop of 350 mbar, at least once every 12 months; the stainless steel meshes at least once every 12 months; activated carbon every 6 months.
Bestsellers
Product sorting
List of products
Stainless steel bracket CHP-WL for fixing a CHP or IHP high-pressure filter of size 018 or 030 to the wall. Load capacity 250 N.
Stainless steel bracket CHP-WM for fixing a CHP or IHP high-pressure filter of size 007 or 010 to the wall. Load capacity 150 N.
Stainless steel bracket CHP-WS for fixing a CHP or IHP high-pressure filter of size 003 or 005 to the wall. Load capacity 100 N.
Stainless steel bracket CHP-WXL for fixing a CHP or IHP high-pressure filter of size 047 to the wall. Load capacity 350 N.
Spare element IHPA-003V for the IHP1A-003, IHP2A-003 and IHP4A-003 activated carbon filters — activated carbon. Replace the activated carbon element every 6 months — it is not...
Spare element IHPA-005V for the IHP1A-005, IHP2A-005 and IHP4A-005 activated carbon filters — activated carbon. Replace the activated carbon element every 6 months — it is not...
Spare element IHPA-007V for the IHP1A-007, IHP2A-007 and IHP4A-007 activated carbon filters — activated carbon. Replace the activated carbon element every 6 months — it is not...
Spare element IHPA-010V for the IHP1A-010, IHP2A-010 and IHP4A-010 activated carbon filters — activated carbon. Replace the activated carbon element every 6 months — it is not...
Spare element IHPA-018V for the IHP1A-018, IHP2A-018 and IHP4A-018 activated carbon filters — activated carbon. Replace the activated carbon element every 6 months — it is not...
Spare element IHPA-030V for the IHP1A-030, IHP2A-030 and IHP4A-030 activated carbon filters — activated carbon. Replace the activated carbon element every 6 months — it is not...
Spare element IHPA-047V for the IHP1A-047, IHP2A-047 and IHP4A-047 activated carbon filters — activated carbon. Replace the activated carbon element every 6 months — it is not...
Spare element IHPA-094V for the IHP1A-094, IHP2A-094 and IHP4A-094 activated carbon filters — activated carbon. Replace the activated carbon element every 6 months — it is not...
Spare element IHPM-003V for the IHP1M-003, IHP2M-003 and IHP4M-003 fine pre-filters — borosilicate microfibres. Replace the element at a pressure drop of 350 mbar, at least once...
Spare element IHPM-005V for the IHP1M-005, IHP2M-005 and IHP4M-005 fine pre-filters — borosilicate microfibres. Replace the element at a pressure drop of 350 mbar, at least once...
Spare element IHPM-007V for the IHP1M-007, IHP2M-007 and IHP4M-007 fine pre-filters — borosilicate microfibres. Replace the element at a pressure drop of 350 mbar, at least once...
Spare element IHPM-010V for the IHP1M-010, IHP2M-010 and IHP4M-010 fine pre-filters — borosilicate microfibres. Replace the element at a pressure drop of 350 mbar, at least once...
Spare element IHPM-018V for the IHP1M-018, IHP2M-018 and IHP4M-018 fine pre-filters — borosilicate microfibres. Replace the element at a pressure drop of 350 mbar, at least once...
Spare element IHPM-030V for the IHP1M-030, IHP2M-030 and IHP4M-030 fine pre-filters — borosilicate microfibres. Replace the element at a pressure drop of 350 mbar, at least once...
Spare element IHPM-047V for the IHP1M-047, IHP2M-047 and IHP4M-047 fine pre-filters — borosilicate microfibres. Replace the element at a pressure drop of 350 mbar, at least once...
Spare element IHPM-094V for the IHP1M-094, IHP2M-094 and IHP4M-094 fine pre-filters — borosilicate microfibres. Replace the element at a pressure drop of 350 mbar, at least once...
Spare element IHPN25-003V for the IHP1N25-003, IHP2N25-003 and IHP4N25-003 coarse filters — stainless steel mesh 1.4301. Replace the element at least once every 12 months.
Spare element IHPN25-005V for the IHP1N25-005, IHP2N25-005 and IHP4N25-005 coarse filters — stainless steel mesh 1.4301. Replace the element at least once every 12 months.
Spare element IHPN25-007V for the IHP1N25-007, IHP2N25-007 and IHP4N25-007 coarse filters — stainless steel mesh 1.4301. Replace the element at least once every 12 months.
Spare element IHPN25-010V for the IHP1N25-010, IHP2N25-010 and IHP4N25-010 coarse filters — stainless steel mesh 1.4301. Replace the element at least once every 12 months.
Spare element IHPN25-018V for the IHP1N25-018, IHP2N25-018 and IHP4N25-018 coarse filters — stainless steel mesh 1.4301. Replace the element at least once every 12 months.
Spare element IHPN25-030V for the IHP1N25-030, IHP2N25-030 and IHP4N25-030 coarse filters — stainless steel mesh 1.4301. Replace the element at least once every 12 months.
Spare element IHPN25-047V for the IHP1N25-047, IHP2N25-047 and IHP4N25-047 coarse filters — stainless steel mesh 1.4301. Replace the element at least once every 12 months.
Spare element IHPN25-094V for the IHP1N25-094, IHP2N25-094 and IHP4N25-094 coarse filters — stainless steel mesh 1.4301. Replace the element at least once every 12 months.
Spare element IHPN5-003V for the IHP1N5-003, IHP2N5-003 and IHP4N5-003 basic filters — stainless steel mesh 1.4301. Replace the element at least once every 12 months.
Spare element IHPN5-005V for the IHP1N5-005, IHP2N5-005 and IHP4N5-005 basic filters — stainless steel mesh 1.4301. Replace the element at least once every 12 months.
Spare element IHPN5-007V for the IHP1N5-007, IHP2N5-007 and IHP4N5-007 basic filters — stainless steel mesh 1.4301. Replace the element at least once every 12 months.
Spare element IHPN5-010V for the IHP1N5-010, IHP2N5-010 and IHP4N5-010 basic filters — stainless steel mesh 1.4301. Replace the element at least once every 12 months.
Spare element IHPN5-018V for the IHP1N5-018, IHP2N5-018 and IHP4N5-018 basic filters — stainless steel mesh 1.4301. Replace the element at least once every 12 months.
Spare element IHPN5-030V for the IHP1N5-030, IHP2N5-030 and IHP4N5-030 basic filters — stainless steel mesh 1.4301. Replace the element at least once every 12 months.
Spare element IHPN5-047V for the IHP1N5-047, IHP2N5-047 and IHP4N5-047 basic filters — stainless steel mesh 1.4301. Replace the element at least once every 12 months.
Spare element IHPN5-094V for the IHP1N5-094, IHP2N5-094 and IHP4N5-094 basic filters — stainless steel mesh 1.4301. Replace the element at least once every 12 months.
Spare element IHPR-003V for the IHP1R-003, IHP2R-003 and IHP4R-003 dust filters. Replace the element at a pressure drop of 350 mbar, at least once every 12 months.
Spare element IHPR-005V for the IHP1R-005, IHP2R-005 and IHP4R-005 dust filters. Replace the element at a pressure drop of 350 mbar, at least once every 12 months.
Spare element IHPR-007V for the IHP1R-007, IHP2R-007 and IHP4R-007 dust filters. Replace the element at a pressure drop of 350 mbar, at least once every 12 months.
Spare element IHPR-010V for the IHP1R-010, IHP2R-010 and IHP4R-010 dust filters. Replace the element at a pressure drop of 350 mbar, at least once every 12 months.