Cyclone separators 16 bar
Cyclone separators work on a fairly simple principle. They change the compressed air flow from straight to rotating thanks to the round shape of the vessel; the rotation and centrifugal force make the condensate droplets we want to remove collect on the inner wall, from where they run down to the bottom and are then drained off. Separators thereby spare the dryers and filters connected downstream, which are no longer under such strain.
Product sorting
List of products
With a G 1" thread and a flow of 3,300 l/min at 7 bar, the AAFC-198 cyclone separator removes liquid water directly after the compressor. Working pressure up to 16 bar.
Spare cyclone element AAFC-510V for the AAFC-510 cyclone separator. Recommended replacement every 12 months or 4,000 operating hours.
With a G 1 1/2" thread and a flow of 8,500 l/min at 7 bar, the AAFC-510 cyclone separator removes liquid water directly after the compressor. Working pressure up to 16 bar.
Spare cyclone element AAFC-120V for the AAFC-120 cyclone separator. Recommended replacement every 12 months or 4,000 operating hours.
Spare cyclone element AAFC-198V for the AAFC-198 cyclone separator. Recommended replacement every 12 months or 4,000 operating hours.
Spare cyclone element AAFC-78V for the AAFC-78 cyclone separator. Recommended replacement every 12 months or 4,000 operating hours.
With a G 1/2" thread and a flow of 1,300 l/min at 7 bar, the AAFC-78 cyclone separator removes liquid water directly after the compressor. Working pressure up to 16 bar.
Spare cyclone element AAFC-1000V for the AAFC-1000 cyclone separator. Recommended replacement every 12 months or 4,000 operating hours.
Spare cyclone element AAFC-1500V for the AAFC-1500 cyclone separator. Recommended replacement every 12 months or 4,000 operating hours.
With a G 3/8" thread and a flow of 1,000 l/min at 7 bar, the AAFC-60 cyclone separator removes liquid water directly after the compressor. Working pressure up to 16 bar.
With a G 2" thread and a flow of 16,667 l/min at 7 bar, the AAFC-1000 cyclone separator removes liquid water directly after the compressor. Working pressure up to 16 bar.
With a G 2" thread and a flow of 25,000 l/min at 7 bar, the AAFC-1500 cyclone separator removes liquid water directly after the compressor. Working pressure up to 16 bar.
With a G 3" thread and a flow of 36,000 l/min at 7 bar, the AAFC-2160 cyclone separator removes liquid water directly after the compressor. Working pressure up to 16 bar.
With a G 3/4" thread and a flow of 2,000 l/min at 7 bar, the AAFC-120 cyclone separator removes liquid water directly after the compressor. Working pressure up to 16 bar.
Spare cyclone element AAFC-60V for the AAFC-60 cyclone separator. Recommended replacement every 12 months or 4,000 operating hours.
CSSS cyclonic separator with DN200 flange connection. Allows for cost-effective and efficient removal of water and impurities from compressed air. Working pressure 16 bar,...
Cyclonic separator CSSS with DN150 flange connection. Enables cost-effective and efficient removal of water and impurities from compressed air. Working pressure 16 bar, working...
Cyclone separator SFH with DN350 flange connection. Enables cost-effective and efficient removal of water and impurities from compressed air. Working pressure 16 bar, working...
Spare cyclone element AAFC-2160V for the AAFC-2160 cyclone separator. Recommended replacement every 12 months or 4,000 operating hours.