PPA filter system for painting up to 16 bar
|  | 
 | 
| PPA compressed air filtration system for painting equipment and paint shops | ||||||||||||
| Ordering number | Connection " | Quick couplings | Pressure bar | Separator | Microfilter | Microfilter | Activated carbon | Flow rates | Dimensions mm | |||
| EC - DN7.2 | centrifugal | 0.1 µm | 0.01 µm | 0.005 µm | l/min | m³/h | and | b | c | |||
| PPA-207 | 1/2" | 2 x safety | 16 | Yes | Yes | Yes | - | 1 300 | 78 | 440 | 135 | 290 | 
| PPA-207C | 1/2" | 2 x safety | 16 | - | Yes | Yes | - | 1 300 | 78 | 440 | 135 | 290 | 
| PPA-307 | 1/2" | 2 x safety | 16 | - | Yes | Yes | Yes | 1 300 | 78 | 530 | 135 | 290 | 
| PPA-307C | 1/2" | 2 x safety | 16 | Yes | Yes | Yes | - | 1 300 | 78 | 530 | 135 | 290 | 
| Reference flow conditions: temperature +20°C, working pressure 7 bar; for other conditions a correction factor must be used for calculation *C - Version for systems without air dryer. Worse air quality at the inlet. | ||||||||||||
| Correction factor - Working pressure | |||||||||||||||
| Working pressure bar | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 | 14 | 15 | 16 | 
| Correction factor | 0,38 | 0,50 | 0,63 | 0,75 | 0,88 | 1,00 | 1,13 | 1,25 | 1,38 | 1,50 | 1,63 | 1,75 | 1,88 | 2,00 | 2,13 | 
Bestsellers
List of products
 
                                    
                                                                                                                                    
    
    
    Modular filter system PPA-207 for supplying clean air with a pre-supervised air dryer in ducts. Concept combining pre-filter, microfilter, pressure regulator and 2 quick...
 
                                                                                                                                    
    
    
    Modular filtration system PPA-207C for clean air supply without air dryer in the ducts. Concept combining microfilter, cyclone separation, dryer, pressure regulator and quick...
 
                                                                                                                                    
    
    
    PPA-307 modular filtration system for clean air supply with pre-set air dryer in ductwork. Concept combining microfilter, activated carbon, pressure regulator and 2 quick...
 
                                                                                                                                    
    
    
    Modular filtration system PPA-307C for clean air supply without air dryer in the ducts. Concept combining cyclone separator, pre-filter, microfilter, pressure regulator and 2...

 
                    
                
         
                
         
                
        