Timed condensate drain CTD16

The CTD16 is a timed drain with an integrated ball valve — so the valve can be shut by hand without taking the whole line out of service. It also has an easily cleaned screen, two LEDs and a test button.
Specifications
One unit for ordinary systems up to 16 bar.
| Timed CTD16 drain — capacity, connection and pressure | |||||
|---|---|---|---|---|---|
| Order code | Capacity | Connection | Working pressure | Temperature | Power supply |
| CTD16 | 258.0 l/h | G 1/2" | 0.2–16 bar | +1 až +60 °C | 230/50 |
#showmore#
How the CTD16 works
A timer relay drives the solenoid valve. It is set with two potentiometers: opening 0.5 to 10 seconds and interval 0.5 to 45 minutes. Two LEDs show the operating state and a test button opens the valve by hand.
Like every timed drain it cannot tell whether there is anything to let out. Its advantage is the integrated ball valve — when the valve needs cleaning or replacing, you shut it on the spot without taking the line down.
Fitting
The inlet has a double thread: male G 1/2" and female 1/4", so it suits either. The condensate outlet takes a 12 mm push-in fitting. Supply 230 V / 50 Hz, working temperature +1 to +60 °C.
What to watch
The screen has to be cleaned, or the valve blocks. The integrated ball valve lets you do it without taking the line down — but somebody still has to do it.
Ventilek says
A ball valve on the drain itself saves taking the whole line down.
This is the small thing you appreciate at the first service. An ordinary timed drain has to be disconnected to clean the screen — and that means venting the whole branch. The CTD16 has the valve built in: shut, clean, open, and the rest of the workshop never notices.
Frequently asked questions — timed ctd16
- What does the double inlet thread mean?
- The inlet has a male G 1/2" and a female 1/4" at once, so it can be connected either way depending on what you have.
- What is the ball valve for?
- For shutting the valve by hand. It helps when cleaning the screen or replacing the unit — you do not have to take the whole line out of service.
- How is it set?
- With two potentiometers: opening 0.5–10 seconds and interval 0.5–45 minutes. The setting follows how much condensate you actually produce.
Product sorting
List of products
A timed condensate drain with a solenoid valve, an integrated ball valve and a cleanable screen. Adjustable opening and interval, two LEDs and a test button.