Air pressure regulators 286, 274 and 280 with inlet up to 40 bar

Pressure regulators of the 286, 274 and 280 series by EWO reduce the pressure of compressed air from a high-pressure air network or air receiver – up to 40 bar – to the working pressure required by the machine, tool or test station. They keep the set pressure constant even when the network pressure fluctuates and air consumption changes.
They are diaphragm regulators with secondary venting and a brass body: when you reduce the set pressure, they release the excess air from the outlet by themselves, even with no air being consumed. A pressure gauge is included. Four body sizes cover flow rates from 468 to 12,160 l/min and threads from G 1/4" to G 1 1/2".
What the 286, 274 and 280 regulators offer
- inlet pressure up to 40 bar – for high-pressure air networks and air receivers
- secondary venting – you can reduce the outlet pressure even with no air being consumed
- control ranges 0.5–3, 0.5–6, 0.5–10, 0.5–16 and 0.5–25 bar
- the outlet barely moves when the network pressure changes – with the large BG 60 and BG 80 regulators, inlet pressure influence below 1.5 %
- pressure gauge included: ⌀ 40 mm for BG 20, ⌀ 63 mm for the other sizes, front or rear mounting
- brass body and spring housing, NBR diaphragm and seals
- adjustment with a handwheel, T-handle or hexagon screw depending on the size and range
- any mounting position, operation from −10 to +90 °C
- for compressed air as well as neutral and non-toxic gases
Four body sizes
The body size determines the flow rate. BG 20 and BG 40 are compact regulators with a handwheel for individual machines, BG 60 and BG 80 are large regulators with a T-handle for entire branches of the air network. Within one size, both threads have the same flow rate – the smaller thread (G 3/4" for BG 60, G 1 1/4" for BG 80) simply has a reduced inlet and outlet.
| Size | Codes | Threads | Flow rate | Nominal size | Inlet pressure influence | Pressure gauge | Dimensions | Weight |
|---|---|---|---|---|---|---|---|---|
| BG 20 | 286.32…, DR1140-25 | G 1/4" | 468 l/min | DN 6 | < 10 % | ⌀ 40 mm | 45 × 104 mm | 0.34–0.56 kg |
| BG 40 | 274.66… | G 1/2" | 1,359 l/min | DN 12 | < 4 % | ⌀ 63 mm | 72 × 145 mm | 1.07–1.19 kg |
| BG 60 | 280.38…, 280.39… | G 3/4"*, G 1" | 7,830 l/min | DN 20 | < 1.5 % | ⌀ 63 mm | 116 × 138 × 216 mm | 3.51–3.88 kg |
| BG 80 | 280.310…, 280.311… | G 1 1/4"*, G 1 1/2" | 12,160 l/min | DN 25 | < 1.5 % | ⌀ 63 mm | 128 / 116 × 138 × 240 mm | 5.32–5.72 kg |
* reduced inlet and outlet (reducers supplied) · Flow rate according to the manufacturer at an inlet pressure of 8 bar, an outlet pressure of 6 bar and a pressure drop of 1 bar. Dimensions: width × overall height; for BG 60 and BG 80, width × depth with pressure gauge × overall height.
All regulators with inlet up to 40 bar
| Code | Size | Thread | Control range | Flow rate | Pressure gauge | Weight |
|---|---|---|---|---|---|---|
| 286.321 | BG 20 | G 1/4" | 0.5–3 bar | 468 l/min | 0–6 bar | 0.42 kg |
| 286.322 | BG 20 | G 1/4" | 0.5–6 bar | 468 l/min | 0–10 bar | 0.42 kg |
| 286.323 | BG 20 | G 1/4" | 0.5–10 bar | 468 l/min | 0–16 bar | 0.56 kg |
| 286.324 | BG 20 | G 1/4" | 0.5–16 bar | 468 l/min | 0–25 bar | 0.43 kg |
| DR1140-25 | BG 20 | G 1/4" | 0.5–25 bar | 468 l/min | without gauge | 0.34 kg |
| 274.661 | BG 40 | G 1/2" | 0.5–3 bar | 1,359 l/min | 0–6 bar | 1.07 kg |
| 274.662 | BG 40 | G 1/2" | 0.5–6 bar | 1,359 l/min | 0–10 bar | 1.07 kg |
| 274.663 | BG 40 | G 1/2" | 0.5–10 bar | 1,359 l/min | 0–16 bar | 1.18 kg |
| 274.664 | BG 40 | G 1/2" | 0.5–16 bar | 1,359 l/min | 0–25 bar | 1.19 kg |
| 274.665 | BG 40 | G 1/2" | 0.5–25 bar | 1,359 l/min | 0–40 bar | 1.18 kg |
| 280.381 | BG 60 | G 3/4"* | 0.5–3 bar | 7,830 l/min | 0–6 bar | 3.64 kg |
| 280.382 | BG 60 | G 3/4"* | 0.5–6 bar | 7,830 l/min | 0–10 bar | 3.64 kg |
| 280.383 | BG 60 | G 3/4"* | 0.5–10 bar | 7,830 l/min | 0–16 bar | 3.75 kg |
| 280.384 | BG 60 | G 3/4"* | 0.5–16 bar | 7,830 l/min | 0–25 bar | 3.64 kg |
| 280.385 | BG 60 | G 3/4"* | 0.5–25 bar | 7,830 l/min | 0–40 bar | 3.64 kg |
| 280.391 | BG 60 | G 1" | 0.5–3 bar | 7,830 l/min | 0–6 bar | 3.54 kg |
| 280.392 | BG 60 | G 1" | 0.5–6 bar | 7,830 l/min | 0–10 bar | 3.54 kg |
| 280.393 | BG 60 | G 1" | 0.5–10 bar | 7,830 l/min | 0–16 bar | 3.64 kg |
| 280.394 | BG 60 | G 1" | 0.5–16 bar | 7,830 l/min | 0–25 bar | 3.51 kg |
| 280.395 | BG 60 | G 1" | 0.5–25 bar | 7,830 l/min | 0–40 bar | 3.88 kg |
| 280.3101 | BG 80 | G 1 1/4"* | 0.5–3 bar | 12,160 l/min | 0–6 bar | 5.42 kg |
| 280.3102 | BG 80 | G 1 1/4"* | 0.5–6 bar | 12,160 l/min | 0–10 bar | 5.42 kg |
| 280.3103 | BG 80 | G 1 1/4"* | 0.5–10 bar | 12,160 l/min | 0–16 bar | 5.66 kg |
| 280.3104 | BG 80 | G 1 1/4"* | 0.5–16 bar | 12,160 l/min | 0–25 bar | 5.72 kg |
| 280.3105 | BG 80 | G 1 1/4"* | 0.5–25 bar | 12,160 l/min | 0–40 bar | 5.52 kg |
| 280.3111 | BG 80 | G 1 1/2" | 0.5–3 bar | 12,160 l/min | 0–6 bar | 5.32 kg |
| 280.3112 | BG 80 | G 1 1/2" | 0.5–6 bar | 12,160 l/min | 0–10 bar | 5.32 kg |
| 280.3113 | BG 80 | G 1 1/2" | 0.5–10 bar | 12,160 l/min | 0–16 bar | 5.42 kg |
| 280.3114 | BG 80 | G 1 1/2" | 0.5–16 bar | 12,160 l/min | 0–25 bar | 5.32 kg |
| 280.3115 | BG 80 | G 1 1/2" | 0.5–25 bar | 12,160 l/min | 0–40 bar | 5.42 kg |
How to choose a regulator
- Control range according to the working pressure. Choose a range whose upper limit is above the pressure you want to set – but not unnecessarily high, as the pressure can be set more finely in a smaller range. For 6 bar, the 0.5–10 bar range is suitable; for 20 bar, the 0.5–25 bar range.
- Size according to air consumption. Add up the air consumption of the machines and tools downstream of the regulator. BG 20 handles 468 l/min, BG 40 1,359 l/min, BG 60 7,830 l/min and BG 80 12,160 l/min. At a lower network pressure, less air flows through – in that case choose a larger size.
- Thread according to the pipework. BG 20 has G 1/4", BG 40 G 1/2", BG 60 G 3/4" or G 1" and BG 80 G 1 1/4" or G 1 1/2". The flow rate does not depend on the thread; reducers for the smaller thread are supplied.
- Adjustment. BG 20 and BG 40 are adjusted with a handwheel (BG 40 with the 0.5–25 bar range with an SW 14 hexagon screw), BG 60 and BG 80 up to 10 bar with a T-handle and in the 0.5–16 and 0.5–25 bar ranges with an SW 19 hexagon screw – such a regulator is adjusted with a spanner.
Example: a 40 bar air network, with a machine downstream of the regulator requiring 10 bar and consuming 3,000 l/min. Neither BG 20 nor BG 40 can handle such a flow rate; size BG 60 with the 0.5–16 bar range is suitable – with a G 1" connection, this is 280.394.
Not sure which regulator to choose? Try the pressure regulator selector – based on line pressure, required pressure and flow.
#showmore#
How a regulator with secondary venting works

- With the handwheel, T-handle or screw you tension the spring. The spring presses on the diaphragm, which opens the valve – air flows from the inlet to the outlet.
- The outlet pressure pushes on the diaphragm against the spring. When it reaches the set value, the valve partially closes and only as much air flows through as is being consumed.
- A change in the network pressure only partly shows at the outlet: less than 10 % for BG 20, less than 4 % for BG 40 and less than 1.5 % for BG 60 and BG 80. Where a constant pressure matters even with large fluctuations in the network, choose a larger size.
- When you reduce the set pressure or the outlet pressure rises, the diaphragm opens the vent hole and the excess air escapes. The difference between the valve closing and the start of venting is about 1 bar.
Flow curves
The manufacturer’s graphs for the large BG 60 and BG 80 regulators show how the outlet pressure drops as the flow rate increases. Each line starts at a set pressure of 2, 4, 6, 8 and 10 bar; the inlet pressure is always 2 bar higher than the outlet pressure. The flatter the line, the more stable the pressure at high air consumption. The manufacturer does not publish curves for BG 20 and BG 40.




The manufacturer does not publish curves for sizes BG 20 and BG 40 in its catalogue – we have taken them from the technical documentation of regulators of identical design. The conditions are the same: the inlet pressure is 2 bar higher than the outlet pressure.
Dimensions
Dimensional drawings from the manufacturer’s catalogue, dimensions in mm: width × overall height, for BG 60 and BG 80 width × depth with pressure gauge × overall height. The drawing of size BG 40 is above, next to the description of how the regulator works.



Installation and adjustment
- install a compressed air filter that can withstand the pressure in your air network upstream of the regulator – dirt from the pipework would damage the valve seat
- install the regulator so that the air flows in the direction of the arrow on the body; any mounting position is possible
- the pressure gauge is supplied loose – screw it in at the front or the back, depending on where you will read it from
- set the pressure from below: loosen the handwheel, T-handle or screw to below the required value, then tighten it until the pressure gauge shows the required pressure; on BG 20 and BG 40, secure the setting with the lock nut
- the regulator is fixed to a wall with a bracket; BG 20 and BG 40 can also be mounted in a control panel by the thread on the spring housing (M20 × 1.5 for BG 20, M28 × 1.5 for BG 40); panel mounting is not available for BG 60 and BG 80

Both the bracket and the panel nut are fixed by the thread on the spring housing. In a panel: the nut clamps the regulator in the panel opening (A). On a wall or frame: the nut on the same thread clamps the bracket, which is then screwed on (B).
Parts by size: BG 20 – bracket BW1040 and nut SM1040 (M20 × 1.5), BG 40 – bracket BW3040 and nut SM3040 (M28 × 1.5), BG 60 and BG 80 – bracket BW5040; panel mounting is not available for them.
Spare parts and accessories
The diaphragm and the valve cone in the regulator wear over time – replace them and the regulator will keep on working. Add a bracket and a panel nut when you mount the regulator on a wall or in a panel.
| Size | Diaphragm | Valve cone | Bracket | Panel nut |
|---|---|---|---|---|
| BG 20 (286, G 1/4") | MEMBRANEDR1140 | DKDR1140 | BW1040 | SM1040 |
| BG 40 (274, G 1/2") | MEMBRANEDR3340 | DKDR3340 | BW3040 | SM3040 |
| BG 60 (280, G 3/4", G 1") | MEMBRANEDR5540, for 0.5–25 bar MEMBRANEDR5540-25 | DKDR5540 | BW5040 | – |
| BG 80 (280, G 1 1/4", G 1 1/2") | MEMBRANEDR7740, for 0.5–25 bar MEMBRANEDR7740-25 | DKDR7740 | BW5040 | – |
The diaphragms and valve cones in the table are for ranges from 0.5–6 bar upwards; for regulators with the 0.5–3 bar range, we will find the right part for you based on the regulator code.
Spare pressure gauge ⌀ 63 mm (BG 40, BG 60 and BG 80) according to the control range: 0.5–3 bar → 213, 0.5–6 bar → 214, 0.5–10 bar → 215, 0.5–16 bar → 216. We will find the ⌀ 40 mm pressure gauge for BG 20 and the 0–40 bar pressure gauge for the 0.5–25 bar range for you based on the regulator code.
You will find all parts for the regulators in the category spare parts and accessories for pressure regulators.
Series specifications
| Parameter | Value |
|---|---|
| Inlet pressure | max. 40 bar (PN 40) |
| Control ranges | 0.5–3 / 0.5–6 / 0.5–10 / 0.5–16 / 0.5–25 bar |
| Flow rate | 468 / 1,359 / 7,830 / 12,160 l/min (BG 20 / BG 40 / BG 60 / BG 80) |
| Nominal size | DN 6 / DN 12 / DN 20 / DN 25 |
| Inlet pressure influence | < 10 % (BG 20), < 4 % (BG 40), < 1.5 % (BG 60 and BG 80) |
| Secondary venting | yes, hysteresis approx. 1 bar |
| Pressure gauge | ⌀ 40 mm (BG 20), ⌀ 63 mm (BG 40, BG 60, BG 80), range 0–6 to 0–40 bar depending on the control range, included |
| Adjustment | handwheel (BG 20, BG 40), SW 14 hexagon screw (BG 40, 0.5–25 bar), T-handle (BG 60, BG 80 up to 10 bar), SW 19 hexagon screw (BG 60, BG 80, 16 and 25 bar) |
| Mounting | on a wall with a bracket; in a panel only BG 20 (M20 × 1.5) and BG 40 (M28 × 1.5) |
| Mounting position | any, flow in the direction of the arrow |
| Operating temperature | −10 to +90 °C |
| Medium | compressed air, neutral and non-toxic gases |
| Material | brass body and spring housing, NBR diaphragm and seals |
Ventilek advises
Install the regulator downstream of the filter and as close to the point of use as possible. The pressure gauge then shows the pressure the machine really receives. And choose a range with some reserve above the working pressure, not right at its limit.
- network pressure up to 25 bar: regulators 280 and 406
- inlet pressure up to 60 bar: regulators 302, up to 200 bar: high-pressure regulators
- high flow rate at 40 bar: regulators 417 up to 25,000 l/min
- very precise control: FDR regulators
- What is secondary venting?
- The regulator can release air from the outlet by itself. When you reduce the set pressure, the excess air escapes through the vent hole and the pressure drops immediately, not only once air is consumed. A short hiss when reducing the pressure is therefore normal.
- Which control range should I choose?
- One whose upper limit is above the required pressure. For 6 bar, the 0.5–10 bar range is suitable; for 20 bar, the 0.5–25 bar range. A range that is too large (for example 0.5–25 bar for 3 bar) only allows coarse adjustment.
- Is the pressure gauge included?
- Yes. BG 20 has a ⌀ 40 mm pressure gauge, the other sizes ⌀ 63 mm. The range of the pressure gauge matches the control range: 0–6 bar for 0.5–3 bar, 0–10 bar for 0.5–6 bar, 0–16 bar for 0.5–10 bar, 0–25 bar for 0.5–16 bar and 0–40 bar for 0.5–25 bar. It is supplied loose; you screw it in at the front or the back.
- Why does the G 3/4" regulator have the same flow rate as the G 1" one?
- Both have the same body of size BG 60. The G 3/4" version simply has a reduced inlet and outlet; the reducers are supplied. The same applies to BG 80 with G 1 1/4" and G 1 1/2". The flow rate is determined by the body size, not by the thread.
- Can I use a regulator rated up to 40 bar in a standard air network?
- Yes, 40 bar is the upper limit of the inlet pressure; the regulator also works at a lower network pressure. At a lower inlet pressure, less air simply flows through.
- What if I have more than 40 bar in the air network?
- Then you need a regulator for a higher inlet pressure – the 302 series up to 60 bar or high-pressure regulators up to 200 bar.
- Can I use the regulator for a gas other than air?
- The manufacturer specifies it for compressed air and neutral, non-toxic gases. For any other gas, please ask us before ordering.
Technical data according to the manufacturer EWO. Flow rate measured at an inlet pressure of 8 bar, an outlet pressure of 6 bar and a pressure drop of 1 bar.
You will find more regulators in the category air pressure regulators.
Product sorting
List of products
EWO diaphragm pressure regulator with a brass body and secondary venting for compressed air and neutral gases.connection G 1/4"control range 0.5–3 bar, inlet pressure up to 40...
EWO diaphragm pressure regulator with a brass body and secondary venting for compressed air and neutral gases.connection G 1/2"control range 0.5–3 bar, inlet pressure up to 40...
EWO diaphragm pressure regulator with a brass body and secondary venting for compressed air and neutral gases.connection G 1/2"control range 0.5–6 bar, inlet pressure up to 40...
EWO diaphragm pressure regulator with a brass body and secondary venting for compressed air and neutral gases.connection G 1/2"control range 0.5–16 bar, inlet pressure up to 40...
EWO diaphragm pressure regulator with a brass body and secondary venting for compressed air and neutral gases.connection G 1/2"control range 0.5–25 bar, inlet pressure up to 40...
EWO diaphragm pressure regulator with a brass body and secondary venting for compressed air and neutral gases.connection G 1"control range 0.5–16 bar, inlet pressure up to 40...
EWO diaphragm pressure regulator with a brass body and secondary venting for compressed air and neutral gases.connection G 1/4"control range 0.5–6 bar, inlet pressure up to 40...
EWO diaphragm pressure regulator with a brass body and secondary venting for compressed air and neutral gases.connection G 1/4"control range 0.5–16 bar, inlet pressure up to 40...
EWO diaphragm pressure regulator with a brass body and secondary venting for compressed air and neutral gases.connection G 1/4"control range 0.5–10 bar, inlet pressure up to 40...
EWO diaphragm pressure regulator with a brass body and secondary venting for compressed air and neutral gases.connection G 1"control range 0.5–25 bar, inlet pressure up to 40...
EWO diaphragm pressure regulator with a brass body and secondary venting for compressed air and neutral gases.connection G 1"control range 0.5–6 bar, inlet pressure up to 40...
EWO diaphragm pressure regulator with a brass body and secondary venting for compressed air and neutral gases.connection G 3/4" (reduced inlet and outlet)control range 0.5–6...
EWO diaphragm pressure regulator with a brass body and secondary venting for compressed air and neutral gases.connection G 1/2"control range 0.5–10 bar, inlet pressure up to 40...
EWO diaphragm pressure regulator with a brass body and secondary venting for compressed air and neutral gases.connection G 1"control range 0.5–10 bar, inlet pressure up to 40...
EWO diaphragm pressure regulator with a brass body and secondary venting for compressed air and neutral gases.connection G 3/4" (reduced inlet and outlet)control range 0.5–25...
EWO diaphragm pressure regulator with a brass body and secondary venting for compressed air and neutral gases.connection G 1"control range 0.5–3 bar, inlet pressure up to 40...
EWO diaphragm pressure regulator with a brass body and secondary venting for compressed air and neutral gases.connection G 3/4" (reduced inlet and outlet)control range 0.5–10...
EWO diaphragm pressure regulator with a brass body and secondary venting for compressed air and neutral gases.connection G 3/4" (reduced inlet and outlet)control range 0.5–3...
EWO diaphragm pressure regulator with a brass body and secondary venting for compressed air and neutral gases.connection G 1 1/2"control range 0.5–3 bar, inlet pressure up to 40...
EWO diaphragm pressure regulator with a brass body and secondary venting for compressed air and neutral gases.connection G 1 1/4" (reduced inlet and outlet)control range 0.5–6...
EWO diaphragm pressure regulator with a brass body and secondary venting for compressed air and neutral gases.connection G 1 1/4" (reduced inlet and outlet)control range 0.5–16...
EWO diaphragm pressure regulator with a brass body and secondary venting for compressed air and neutral gases.connection G 1 1/2"control range 0.5–10 bar, inlet pressure up to...
EWO diaphragm pressure regulator with a brass body and secondary venting for compressed air and neutral gases.connection G 1 1/4" (reduced inlet and outlet)control range 0.5–10...
EWO diaphragm pressure regulator with a brass body and secondary venting for compressed air and neutral gases.connection G 1 1/2"control range 0.5–6 bar, inlet pressure up to 40...
EWO diaphragm pressure regulator with a brass body and secondary venting for compressed air and neutral gases.connection G 1 1/2"control range 0.5–16 bar, inlet pressure up to...
EWO diaphragm pressure regulator with a brass body and secondary venting for compressed air and neutral gases.connection G 1 1/4" (reduced inlet and outlet)control range 0.5–25...
EWO diaphragm pressure regulator with a brass body and secondary venting for compressed air and neutral gases.connection G 1 1/4" (reduced inlet and outlet)control range 0.5–3...
EWO diaphragm pressure regulator with a brass body and secondary venting for compressed air and neutral gases.connection G 1 1/2"control range 0.5–25 bar, inlet pressure up to...
Precision pressure regulator of the 286 series by EWO, in a version with a 0.5–25 bar control range.inlet pressure up to 40 bar, control range 0.5–25 barconnection G 1/4", flow...
EWO diaphragm pressure regulator with a brass body and secondary venting for compressed air and neutral gases.connection G 3/4" (reduced inlet and outlet)control range 0.5–16...