Pressure regulators 417 for high flow rates, inlet up to 40 bar

Pressure regulators of the 417 series by EWO are designed for high compressed air consumption: entire air networks, production lines, marine and mechanical engineering or PET bottle blowing. They reduce the pressure from the air network or air receiver – up to 40 bar – to the working pressure and keep it constant even when the network pressure fluctuates and air consumption changes.
A single body of size BG 90 with a nominal size of DN 50 passes 25,000 l/min. The regulator has secondary venting and two ⌀ 63 mm pressure gauges – at the inlet and at the outlet. You can choose between a G 1 1/2" or G 2" thread, four control ranges and a version without a lock or a lockable one.
What the 417 regulators offer
- high flow rate of 25,000 l/min at an inlet pressure of 8 bar and an outlet pressure of 6 bar
- inlet pressure up to 40 bar (PN 40)
- the outlet barely moves when the network pressure changes (inlet pressure influence below 1 %)
- secondary venting – you can reduce the outlet pressure even with no air being consumed
- two ⌀ 63 mm pressure gauges included: inlet 0–60 bar and outlet according to the control range
- control ranges 0.5–6, 0.5–10, 0.5–16 and 0.5–25 bar
- pressure adjustment with the handwheel, lockable version with a lock
- cast aluminium body, NBR diaphragm and seals, operation from −10 to +90 °C
Two threads, one body
All 417 regulators have the same body of size BG 90 with a G 2" thread. The G 1 1/2" version comes with reducers supplied with the body, which is why it is slightly wider. The flow rate is the same for both threads.
| Thread | Codes | Flow rate | Nominal size | Inlet pressure influence | Dimensions | Weight |
|---|---|---|---|---|---|---|
| G 1 1/2"* | 417.2112–417.2115, 417.2112A–417.2115A | 25,000 l/min | DN 50 | < 1 % | 180 × 248 mm | 6.0–6.71 kg |
| G 2" | 417.2122–417.2125, 417.2122A–417.2125A | 25,000 l/min | DN 50 | < 1 % | 160 × 248 mm | 5.83–6.71 kg |
* G 2" × G 1 1/2" reducers supplied · Flow rate according to the manufacturer at an inlet pressure of 8 bar, an outlet pressure of 6 bar and a pressure drop of 1 bar. Dimensions: width × overall height including the handwheel.
All 417 regulators
Codes ending in the letter A are lockable – otherwise they are the same as the regulator without a lock with the same number.
| Code | Thread | Control range | Lock | Flow rate | Outlet pressure gauge | Weight |
|---|---|---|---|---|---|---|
| 417.2112 | G 1 1/2" | 0.5–6 bar | no | 25,000 l/min | 0–10 bar | 6.71 kg |
| 417.2112A | G 1 1/2" | 0.5–6 bar | yes | 25,000 l/min | 0–10 bar | 6.0 kg |
| 417.2113 | G 1 1/2" | 0.5–10 bar | no | 25,000 l/min | 0–16 bar | 6.71 kg |
| 417.2113A | G 1 1/2" | 0.5–10 bar | yes | 25,000 l/min | 0–16 bar | 6.0 kg |
| 417.2114 | G 1 1/2" | 0.5–16 bar | no | 25,000 l/min | 0–25 bar | 6.71 kg |
| 417.2114A | G 1 1/2" | 0.5–16 bar | yes | 25,000 l/min | 0–25 bar | 6.0 kg |
| 417.2115 | G 1 1/2" | 0.5–25 bar | no | 25,000 l/min | 0–40 bar | 6.71 kg |
| 417.2115A | G 1 1/2" | 0.5–25 bar | yes | 25,000 l/min | 0–40 bar | 6.0 kg |
| 417.2122 | G 2" | 0.5–6 bar | no | 25,000 l/min | 0–10 bar | 6.71 kg |
| 417.2122A | G 2" | 0.5–6 bar | yes | 25,000 l/min | 0–10 bar | 6.0 kg |
| 417.2123 | G 2" | 0.5–10 bar | no | 25,000 l/min | 0–16 bar | 6.71 kg |
| 417.2123A | G 2" | 0.5–10 bar | yes | 25,000 l/min | 0–16 bar | 6.0 kg |
| 417.2124 | G 2" | 0.5–16 bar | no | 25,000 l/min | 0–25 bar | 5.83 kg |
| 417.2124A | G 2" | 0.5–16 bar | yes | 25,000 l/min | 0–25 bar | 6.0 kg |
| 417.2125 | G 2" | 0.5–25 bar | no | 25,000 l/min | 0–40 bar | 5.84 kg |
| 417.2125A | G 2" | 0.5–25 bar | yes | 25,000 l/min | 0–40 bar | 6.0 kg |
How to choose a regulator
- Control range according to the working pressure. Choose a range whose upper limit is above the pressure you want to set – but not unnecessarily high, as the pressure can be set more finely in a smaller range. For 6 bar, the 0.5–10 bar range is suitable; for 12 bar, the 0.5–16 bar range.
- Flow rate according to air consumption. Add up the air consumption of the machines downstream of the regulator. The 417 regulator handles 25,000 l/min; for lower air consumption, smaller and lighter regulators with inlet up to 40 bar are sufficient.
- Thread according to the pipework. It has no effect on the flow rate – G 2" and G 1 1/2" have the same body; the G 1 1/2" version simply comes with reducers supplied.
- A lock if nobody may change the setting. The lockable version (code ending in A) secures the handwheel with a lock – the pressure can then only be changed by whoever has the key.
Example: a production line needs 7 bar and consumes up to 20,000 l/min, with 16 bar in the air network. The 0.5–10 bar range is suitable; with G 2" pipework, this is 417.2123, and if nobody is to change the setting, the lockable 417.2123A.
Not sure which regulator to choose? Try the pressure regulator selector – based on line pressure, required pressure and flow.
#showmore#

How the regulator works

- With the handwheel you tension the spring. Through the diaphragm, the spring force opens the valve with the valve cone, and air flows from the inlet to the outlet.
- The outlet pressure pushes on the diaphragm against the spring. When it reaches the set value, the valve partially closes and only as much air flows through as is being consumed.
- The manufacturer specifies the regulator as a pilot-operated diaphragm regulator. Less than 1 % of any pressure fluctuation in the network shows at the outlet.
- When you reduce the set pressure or the outlet pressure rises, the diaphragm opens the vent hole and the excess air escapes. The difference between the valve closing and the start of venting is about 0.5 bar.
Flow curve

The manufacturer’s graph shows how the outlet pressure drops as the flow rate increases. Each line starts at a set pressure of 2, 4, 6, 8 and 10 bar; the inlet pressure is always 2 bar higher than the outlet pressure. The flatter the line, the more stable the pressure at high air consumption.
In its 2022 catalogue, the manufacturer states a nominal flow rate of 52,190 l/min, measured at an inlet pressure of 10 bar, an outlet pressure of 8 bar and a pressure drop of 1 bar. The figure of 25,000 l/min applies to an inlet pressure of 8 bar and an outlet pressure of 6 bar.
Lockable version
Regulators with the letter A at the end of the code have a handwheel that can be secured with a lock; the lock is included. No unauthorised person can then change the set pressure – useful wherever production quality or safety depends on the pressure and several people have access to the air network. Specifications, dimensions and flow rate are the same as for the version without a lock.
Dimensions
Both versions have the same BG 90 body and an overall height of 248 mm. The G 1 1/2" version is wider because of the supplied reducers. Dimensions in mm from the manufacturer’s catalogue.


Installation and adjustment
- install a high-pressure compressed air filter upstream of the regulator – dirt from the pipework would damage the valve seat
- install the regulator so that the air flows in the direction of the arrow on the body; any mounting position is possible
- the regulator weighs over 5 kg – support the pipework next to it, or fix it to a wall or frame with a mounting bracket
- set the pressure from below: loosen the handwheel to below the required value, then tighten it until the outlet pressure gauge shows the required pressure
- the pressure gauges can be mounted at the front or the back, depending on where you will read them from; the G 1 1/2" version has reducers supplied with the body
Spare parts and accessories
The diaphragm and the valve cone in the regulator wear over time – replace them and the regulator will keep on working. The parts are the same for G 1 1/2" and G 2", with or without a lock.
| Part | Code | Purpose |
|---|---|---|
| Spare diaphragm | MEMBRANEDR8840 | cracked or hardened diaphragm – air escapes through the vent hole or the regulator does not hold the pressure |
| Valve cone | DKDR8840 | worn seat – the outlet pressure slowly rises with no air being consumed |
| Mounting bracket | BW8040 | mounting the regulator on a wall or frame |
Spare outlet pressure gauge ⌀ 63 mm according to the control range: 0.5–6 bar → 214, 0.5–10 bar → 215, 0.5–16 bar → 216.
You will find all parts for the regulators in the category spare parts and accessories for pressure regulators.
Series specifications
| Parameter | Value |
|---|---|
| Body size | BG 90 |
| Connection | G 1 1/2" (reducers supplied) or G 2" |
| Inlet pressure | max. 40 bar (PN 40) |
| Control ranges | 0.5–6 / 0.5–10 / 0.5–16 / 0.5–25 bar |
| Flow rate | 25,000 l/min (inlet 8 bar, outlet 6 bar, pressure drop 1 bar) |
| Flow rate according to the 2022 catalogue | 52,190 l/min (inlet 10 bar, outlet 8 bar, pressure drop 1 bar) |
| Nominal size | DN 50 |
| Inlet pressure influence | < 1 % |
| Design | pilot-operated diaphragm regulator |
| Secondary venting | yes, hysteresis approx. 0.5 bar |
| Pressure gauges | 2× ⌀ 63 mm included: inlet 0–60 bar, outlet 0–10 to 0–40 bar depending on the control range |
| Adjustment | handwheel, lockable version with a lock |
| Mounting position | any, flow in the direction of the arrow |
| Operating temperature | −10 to +90 °C |
| Medium | compressed air, neutral and non-toxic gases |
| Material | cast aluminium body and spring housing, NBR diaphragm and seals |
| Dimensions (width × height) | 160 × 248 mm (G 2"), 180 × 248 mm (G 1 1/2") |
Ventilek advises
Install the large regulator downstream of the filter and as close to the point of use as possible, and give it a straight length of pipe of the same nominal size. A restriction upstream or downstream of it reduces the flow rate more than the regulator itself does.
- lower air consumption and inlet up to 40 bar: regulators 286
- inlet up to 25 bar: regulators 280 and 406
- inlet up to 60 bar: regulators 302
- pressure set remotely: DRI regulators
- Why does the G 1 1/2" regulator have the same flow rate as the G 2" one?
- Both have the same body of size BG 90 with a G 2" thread. The G 1 1/2" version comes with reducers supplied with the body. The flow rate is determined by the body, not by the thread.
- What is the lockable version for?
- The handwheel is secured with a lock, so no unauthorised person can change the set pressure. The lock is included. The code of a lockable regulator ends in the letter A.
- Which pressure gauges are included?
- Two ⌀ 63 mm pressure gauges. The inlet gauge has a range of 0–60 bar, the outlet gauge one to match the control range: 0–10 bar for 0.5–6 bar, 0–16 bar for 0.5–10 bar, 0–25 bar for 0.5–16 bar and 0–40 bar for 0.5–25 bar. They can be mounted at the front or the back.
- What flow rate can the regulator handle?
- The manufacturer states 25,000 l/min at an inlet pressure of 8 bar, an outlet pressure of 6 bar and a pressure drop of 1 bar; in the 2022 catalogue, 52,190 l/min at an inlet pressure of 10 bar and an outlet pressure of 8 bar. The flow curve shows how the pressure drops at higher air consumption.
- What is secondary venting?
- The regulator can release air from the outlet by itself. When you reduce the set pressure, the excess air escapes through the vent hole and the pressure drops immediately, not only once air is consumed. A short hiss when reducing the pressure is therefore normal.
- Can the pressure be set remotely?
- The 417 regulators are adjusted with the handwheel directly on the regulator. DRI regulators are designed for setting the pressure remotely.
- Can I use the regulator for a gas other than air?
- The manufacturer specifies it for compressed air and neutral, non-toxic gases. For any other gas, please ask us before ordering.
Technical data according to the manufacturer EWO. Flow rate of 25,000 l/min measured at an inlet pressure of 8 bar, an outlet pressure of 6 bar and a pressure drop of 1 bar.
You will find more regulators in the category air pressure regulators.
Product sorting
List of products
Large EWO diaphragm pressure regulator with secondary venting for compressed air and neutral gases.connection G 1 1/2" (reducers supplied with the G 2" body), DN 50control range...
Large EWO diaphragm pressure regulator with secondary venting for compressed air and neutral gases.connection G 1 1/2" (reducers supplied with the G 2" body), DN 50control range...
Large EWO diaphragm pressure regulator with secondary venting for compressed air and neutral gases.connection G 1 1/2" (reducers supplied with the G 2" body), DN 50control range...
Large EWO diaphragm pressure regulator with secondary venting for compressed air and neutral gases.connection G 2", DN 50control range 0.5–6 bar, inlet pressure up to 40 barflow...
Pressure regulator of the 417 series by EWO for high flow rates up to 25,000 l/min and inlet pressure up to 40 bar, in a lockable version: the set pressure can be locked so that...
Pressure regulator of the 417 series by EWO for high flow rates up to 25,000 l/min and inlet pressure up to 40 bar, in a lockable version: the set pressure can be locked so that...
Pressure regulator of the 417 series by EWO for high flow rates up to 25,000 l/min and inlet pressure up to 40 bar, in a lockable version: the set pressure can be locked so that...
Pressure regulator of the 417 series by EWO for high flow rates up to 25,000 l/min and inlet pressure up to 40 bar, in a lockable version: the set pressure can be locked so that...
Pressure regulator of the 417 series by EWO for high flow rates up to 25,000 l/min and inlet pressure up to 40 bar, in a lockable version: the set pressure can be locked so that...
Pressure regulator of the 417 series by EWO for high flow rates up to 25,000 l/min and inlet pressure up to 40 bar, in a lockable version: the set pressure can be locked so that...
Large EWO diaphragm pressure regulator with secondary venting for compressed air and neutral gases.connection G 2", DN 50control range 0.5–16 bar, inlet pressure up to 40...
Large EWO diaphragm pressure regulator with secondary venting for compressed air and neutral gases.connection G 1 1/2" (reducers supplied with the G 2" body), DN 50control range...
Large EWO diaphragm pressure regulator with secondary venting for compressed air and neutral gases.connection G 2", DN 50control range 0.5–25 bar, inlet pressure up to 40...
Large EWO diaphragm pressure regulator with secondary venting for compressed air and neutral gases.connection G 2", DN 50control range 0.5–10 bar, inlet pressure up to 40...
Pressure regulator of the 417 series by EWO for high flow rates up to 25,000 l/min and inlet pressure up to 40 bar, in a lockable version: the set pressure can be locked so that...
Pressure regulator of the 417 series by EWO for high flow rates up to 25,000 l/min and inlet pressure up to 40 bar, in a lockable version: the set pressure can be locked so that...