Compressed air treatment: filtration, drying and pressure regulation, Page 19
-
Treatment units
-
Industrial filtration
-
Air dryers
-
Pressure regulators
-
Cyclone separators
-
Oil-water separators
-
Pressure boosters
Bestsellers
Product sorting
List of products
Precision through-feed regulator FUTURA RBP12-16F, size 2: G 1/2" thread, setting range 0.5–16 bar, accuracy ±25 mbar, flow 5,200 l/min, inlet pressure up to 16 bar, 50 mm...
Volume booster FUTURA RF14-F, size 1: G 1/4" thread, setting range 0.5–16 bar, flow 2,700 l/min.
Volume booster FUTURA RF38-F, size 1: G 3/8" thread, setting range 0.5–16 bar, flow 2,700 l/min.
Precision pressure regulator FUTURA RP14-16F, size 1: G 1/4" thread, setting range 0.5–16 bar, accuracy ±25 mbar, flow 2,000 l/min, inlet pressure up to 16 bar, 50 mm pressure...
Ball valve with exhaust FUTURA K34-F, size 4: G 3/4" thread, flow 25,000 l/min, inlet pressure up to 16 bar, for ATEX environments.
Spare element SF-10 with a orange end cap for the Hankison F10-B-SF basic filter. Replacement: 6,000 h / 12 months.
A replacement regulator diaphragm for a size 2 COMBIBLOC unit. If the regulator does not hold the set pressure or air escapes under the knob, a damaged diaphragm may be the cause.
3/2 valve FUTURA MCL14-F230VAC, size 1: G 1/4" thread, flow 2,000 l/min, 230 V AC coil, inlet pressure up to 10 bar.
Spare element AAFA2-780V for adsorption filter AAFA2-780. Recommended replacement within 6 months at the latest, earlier if the oil content is higher.
With a G 1/2" thread and a flow of 1,416 l/min, the Hankison NGF F04-B-PF dust filter traps solid particles larger than 1 µm with an efficiency of 99.999%, as well as large...
Volume booster FUTURA RF10-F, size 4: G 1" thread, setting range 0.5–16 bar, flow 14,600 l/min.
Volume booster FUTURA RF34-F, size 4: G 3/4" thread, setting range 0.5–16 bar, flow 14,600 l/min.
Manifold module FUTURA VBCL34-F, size 4: G 3/4" thread, flow 18,000 l/min, side ports top and bottom, G 3/4", inlet pressure up to 16 bar, for ATEX environments.
A replacement element for FUTURA pre-filters with 0.3 µm filtration. Replace it when the clogging indicator shows a large pressure difference or the pressure after the filter...
Spare element SF-06 with a orange end cap for the Hankison F06-B-SF basic filter. Replacement: 6,000 h / 12 months.
A replacement bowl for FUTURA activated carbon filters. It has no drain, because the activated carbon filter does not drain condensate. It serves as a replacement for a damaged...
A replacement bowl for FUTURA activated carbon filters. It has no drain, because the activated carbon filter does not drain condensate. It serves as a replacement for a damaged...
Spare element AAFA2-120V for adsorption filter AAFA2-120. Recommended replacement within 6 months at the latest, earlier if the oil content is higher.
Spare element AAFA-510V for activated carbon filter AAFA-510. Recommended replacement within 6 months at the latest, earlier if the oil content is higher.
Soft-start unit FUTURA BFMCL14-24VDC, size 1: G 1/4" thread, flow 1,300 l/min, 24 V DC coil, inlet pressure up to 10 bar.
Soft-start unit FUTURA BFMCL38-24VDC, size 1: G 3/8" thread, flow 1,300 l/min, 24 V DC coil, inlet pressure up to 10 bar.
Replacement activated carbon cartridge for the second chamber of the WOS-20 separator. It captures the remaining oil that has passed through the polypropylene fibres.for the...
3/2 valve FUTURA MCL12-F24VDC, size 2: G 1/2" thread, flow 4,300 l/min, 24 V DC coil, inlet pressure up to 10 bar.
3/2 valve FUTURA MCL382-F24VDC, size 2: G 3/8" thread, flow 4,300 l/min, 24 V DC coil, inlet pressure up to 10 bar.
Ball valve with exhaust FUTURA K10-F, size 4: G 1" thread, flow 25,000 l/min, inlet pressure up to 16 bar, for ATEX environments.
Pressure regulator FUTURA R12-10F, size 2: G 1/2" thread, setting range 0.5–10 bar, flow 5,200 l/min, inlet pressure up to 16 bar, 50 mm pressure gauge included, for ATEX...
A replacement bowl for FUTURA lubricators and units. It serves as a replacement for a damaged lubricator bowl.
A replacement pilot valve with coil for electrically operated FUTURA 3/2 valves and soft-start units of all sizes. Power 2.5 W (3 VA on AC), protection IP 65. It is screwed on...
A replacement pilot valve with coil for electrically operated FUTURA 3/2 valves and soft-start units of all sizes. Power 2.5 W (3 VA on AC), protection IP 65. It is screwed on...
A replacement pilot valve with coil for electrically operated FUTURA 3/2 valves and soft-start units of all sizes. Power 2.5 W (3 VA on AC), protection IP 65. It is screwed on...
Filter housing AAF-78T — head and bowl without element, with a G 1/2" thread and a flow of 1,300 l/min at 7 bar. You choose the element of any stage separately.
A replacement element for FUTURA microfilters with 0.01 µm filtration. Replace it when the clogging indicator shows a large pressure difference or the pressure after the filter...
A replacement element for FUTURA microfilters with 0.01 µm filtration. Replace it when the clogging indicator shows a large pressure difference or the pressure after the filter...
A replacement element for FUTURA microfilters with 0.01 µm filtration. Replace it when the clogging indicator shows a large pressure difference or the pressure after the filter...
A replacement element for FUTURA microfilters with 0.01 µm filtration. Replace it when the clogging indicator shows a large pressure difference or the pressure after the filter...
A replacement element for FUTURA microfilters with 0.01 µm filtration. Replace it when the clogging indicator shows a large pressure difference or the pressure after the filter...
A replacement element for FUTURA microfilters with 0.01 µm filtration. Replace it when the clogging indicator shows a large pressure difference or the pressure after the filter...
A replacement element for FUTURA pre-filters with 0.3 µm filtration. Replace it when the clogging indicator shows a large pressure difference or the pressure after the filter...
Spare element AAFM-335V for fine pre-filter AAFM-335. Recommended replacement every 12 months or 4,000 operating hours.
Spare element AAFH2-78V for catalytic filter AAFH2-78. Recommended replacement within 6 months at the latest, earlier depending on use.