Compact COMBIBLOC air treatment units up to 16 bar

The COMBIBLOC unit combines a filter, a pressure regulator and a lubricator in one body. The lubricator bowl sits inside the filter bowl, so the unit takes up much less space than three devices in a row.
It comes in two sizes with G 1/4" to 1" threads and a flow of 1,400 or 3,400 l/min. You set the pressure within a range of 0.5–6, 0.5–10 or 0.5–16 bar, and the pressure gauge is included.
Which version to choose
The size, thread and range determine the product page. You then choose the bowl and the condensate drain directly on that page.

Size 1
G 1/4", 3/8" and 1/2" threads, flow 1,400 l/min. Width 66 mm, height 220 mm.

Size 2
G 1/2", 3/4" and 1" threads, flow 3,400 l/min. Width 93 mm, height 325 mm.

Metal bowl (-M)
With a sight glass and a metal sight dome. Inlet pressure up to 25 bar, temperature up to 90 °C.

Protective guard (-S)
A plastic bowl in a metal guard, protected from impact. Pressure and temperature as for the plastic bowl.

Automatic drain (-AM)
A float built into the bowl releases the condensate by itself. It works in the range 1.5–12 bar.

Add-on drain (-AMR)
A drain under the bowl with manual override, for 4–16 bar and larger amounts of condensate.
Units by size, thread and range
Codes on one row lead to the same product page. You choose a version with a different bowl or drain at the top of that page.
| Size 1 · flow 1,400 l/min · width 66 mm, height 220 mm | |||||||
|---|---|---|---|---|---|---|---|
| Thread | Range (bar) | Pressure gauge (bar) | Plastic bowl | Metal bowl (-M) | With guard (-S) | Automatic drain (-AM) | Add-on drain (-AMR) |
| G 1/4" | 0.5–6 | 0–10 | 423.222 | 423.222-M | 423.222-S | 423.222-AM | 423.222-AMR |
| G 1/4" | 0.5–10 | 0–16 | 423.223 | 423.223-M | 423.223-S | 423.223-AM | 423.223-AMR |
| G 1/4" | 0.5–16 | 0–25 | 423.224 | 423.224-M | 423.224-S | 423.224-AM | 423.224-AMR |
| G 3/8" | 0.5–6 | 0–10 | 423.232 | 423.232-M | 423.232-S | 423.232-AM | 423.232-AMR |
| G 3/8" | 0.5–10 | 0–16 | 423.233 | 423.233-M | 423.233-S | 423.233-AM | 423.233-AMR |
| G 3/8" | 0.5–16 | 0–25 | 423.234 | 423.234-M | 423.234-S | 423.234-AM | 423.234-AMR |
| G 1/2" | 0.5–6 | 0–10 | 423.242 | 423.242-M | 423.242-S | 423.242-AM | 423.242-AMR |
| G 1/2" | 0.5–10 | 0–16 | 423.243 | 423.243-M | 423.243-S | 423.243-AM | 423.243-AMR |
| G 1/2" | 0.5–16 | 0–25 | 423.244 | 423.244-M | 423.244-S | 423.244-AM | 423.244-AMR |
| Size 2 · flow 3,400 l/min · width 93 mm, height 325 mm | |||||||
|---|---|---|---|---|---|---|---|
| Thread | Range (bar) | Pressure gauge (bar) | Plastic bowl | Metal bowl (-M) | With guard (-S) | Automatic drain (-AM) | Add-on drain (-AMR) |
| G 1/2" | 0.5–6 | 0–10 | 423.262 | 423.262-M | 423.262-S | 423.262-AM | 423.262-AMR |
| G 1/2" | 0.5–10 | 0–16 | 423.263 | 423.263-M | 423.263-S | 423.263-AM | 423.263-AMR |
| G 1/2" | 0.5–16 | 0–25 | 423.264 | 423.264-M | 423.264-S | 423.264-AM | 423.264-AMR |
| G 3/4" | 0.5–6 | 0–10 | 423.282 | 423.282-M | 423.282-S | 423.282-AM | 423.282-AMR |
| G 3/4" | 0.5–10 | 0–16 | 423.283 | – | 423.283-S | 423.283-AM | 423.283-AMR |
| G 3/4" | 0.5–16 | 0–25 | 423.284 | – | 423.284-S | 423.284-AM | 423.284-AMR |
| G 1" | 0.5–6 | 0–10 | 423.292 | 423.292-M | 423.292-S | 423.292-AM | 423.292-AMR |
| G 1" | 0.5–10 | 0–16 | 423.293 | – | 423.293-S | 423.293-AM | 423.293-AMR |
| G 1" | 0.5–16 | 0–25 | 423.294 | 423.294-M | 423.294-S | 423.294-AM | 423.294-AMR |
“–” = this version is not supplied for the given thread and range. The Ø 50 mm pressure gauge has a scale matching the range and is included.
#showmore#
Controls

1 The dosing screw sets the oil quantity: clockwise for less, anticlockwise for more.
2 The sight glass shows the oil drops, which you use to check the dose.
3 The filling screw is opened when you top up the oil. Leave free access to it.
4 The regulator knob sets the outlet pressure: clockwise for higher, anticlockwise for lower.
5 The condensate drain opens anticlockwise and closes clockwise.
How to set the pressure
Pull the regulator knob out slightly and turn it to the left to relieve the regulator. Then turn it to the right until the gauge shows the required pressure, and push the knob in to lock it.
The inlet pressure must be at least 2 bar higher than the set pressure. The regulator then keeps the outlet constant even when the air line pressure fluctuates. Choose the range according to the pressure the consumer needs: from an 8 bar air line, you can set about 6 bar at most.
Oil and dosing
The lubricator adds oil from a flow of about 50 l/min (at 2 bar) and needs an inlet pressure of at least 0.5 bar. That is why it does not drip when little air is drawn. You set the dose with the dosing screw during operation and check it by counting the drops in the sight glass.
Top up the oil through the filling screw to about 2/3 of the bowl, up to the mark. You do not need to shut off the air supply to do so.
The plastic bowl takes mineral oil with a viscosity of 22–32 cSt at 40 °C, or up to 68 cSt for percussion tools. Synthetic oils, oils with additives and antifreeze damage polycarbonate, so for other oils choose the metal bowl. We offer SOL for temperatures above +5 °C, SOLWI for operation with larger amounts of condensate and the food-grade SOLLE.
Bowls and condensate drain

The bowl is double: condensate from the filter collects at the bottom, and the inner bowl holds the oil reserve. In size 1 this is 25 cm³ of condensate and 75 cm³ of oil; in size 2, 75 and 150 cm³.
The standard version has a manual drain: drain the condensate regularly through the outlet at the bottom of the bowl. The automatic drain built into the bowl releases the condensate by itself in the range 1.5–12 bar. The add-on drain works from 4 to 16 bar; below 4 bar it stays closed, and you then release the condensate by pressing the manual override pin. Its outlet has a G 1/4" female thread for a hose.
The AMR drain can be retrofitted in place of the manual drain: directly onto a bowl with a G 1/8" thread, or onto a 14 mm hole using the AMR-CL adapter. As a spare part, there is also a bowl with a semi-automatic drain, which releases the condensate when the pressure drops, for example after the supply is shut off.
Mounting

Mount the unit upright, in the direction of the arrow on the body and as close to the consumer as possible, no more than 10 m before it. Fix it to a wall or machine frame with the mounting bracket.
For transport, the pressure gauge is supplied loose. Screw it into the G 1/4" thread at the front or rear.
Dimensions

Width A, overall height G and depth with pressure gauge M decide whether the unit fits. Leave free space under the bowl for unscrewing it and for draining the condensate.
| Dimensions according to the drawing (mm) | ||
|---|---|---|
| Dimension | Size 1 | Size 2 |
| A – width | 66 | 93 |
| B | 200 | 295 |
| C – body depth | 69 | 96 |
| E | 65 | 105 |
| F | 34.5 | 48 |
| G – overall height | 220 | 325 |
| J | 82 | 112 |
| K | 43 | 61 |
| L | 6.5 | 9 |
| M – depth with pressure gauge | 105 | 135 |
Maintenance

Drain the condensate regularly; an automatic drain is the more reliable option. Clean the element without pressure: unscrew the bowl, loosen the element nut, wash the element in solvent, blow it through from the inside out and let it dry.
About every six months, remove the baffle disc, the element and the regulator sealing cone, and grease the O-ring and guide pin of the cone.
Wash the plastic bowl only with water, kerosene or petroleum spirit. Petrol from a filling station, acetone and thinners damage it. Do not add alcohol or antifreeze to the oil.
Spare parts and accessories by size
On the page of each unit, the parts for its size are offered as related products.
| COMBIBLOC spare parts and accessories | ||
|---|---|---|
| Part | Size 1 | Size 2 |
| Mounting bracket with screws | 423-60 | 423-102 |
| Protective bowl guard | 423-107 | 423-108 |
| Plastic bowl, manual drain | 423-282 | 423-283 |
| Plastic bowl, automatic drain | 423-288 | 423-289 |
| Plastic bowl, semi-automatic drain | BFKOM1-HA | BFKOM2-HA |
| Plastic bowl with add-on drain | BFKOM1-AMR | BFKOM2-AMR |
| Metal bowl, manual drain | 423-296 | 423-297 |
| Metal bowl, semi-automatic drain | BFMKOM1-HA | – |
| Metal bowl with add-on drain | BFMKOM1-AMR | BFMKOM2-AMR |
| Filter element 40 µm | 394-6 | 394-16 |
| Filter element 5 µm | 394-40 | 394-37 |
| Regulator diaphragm | 480-92 | 423-77 |
| Regulator sealing cone | DKKOM1 | DKKOM2 |
| Sight dome, plastic | TROPFKOM | |
| Sight dome, metal | TROPFKOM-M | |
| Add-on condensate drain | AMR | |
| Drain adapter for a 14 mm hole | AMR-CL | |
When to choose another range
If you need a separate filter, regulator or lubricator, finer filtration or a unit for potentially explosive atmospheres, take a look at FUTURA air treatment units. COMBIBLOC units are not intended for ATEX environments.
Ventilek’s tip
A metal bowl for heat and other oils. The plastic bowl withstands 50 °C at most and mineral oil only. Where it is warmer, where the inlet is above 16 bar or where synthetic oil is used, choose the -M version.
- What is the difference from a three-piece unit?
- The filter, regulator and lubricator are in one body, and the lubricator bowl sits inside the filter bowl. The unit is therefore smaller: size 1 is 66 mm wide.
- What inlet pressure can the unit take?
- 16 bar with a plastic bowl or with a guard, 25 bar with a metal bowl. The regulator needs at least 2 bar more at the inlet than you set.
- Why does the lubricator not drip?
- It only adds oil from a flow of about 50 l/min (at 2 bar). That is why it does not drip when little air is drawn.
- Can oil be topped up during operation?
- Yes, through the filling screw without shutting off the supply, to about 2/3 of the bowl, up to the mark.
- Can an automatic drain be retrofitted?
- Yes. Replace the bowl with a version with automatic drain, or fit the AMR add-on drain in place of the manual drain, onto a 14 mm hole using the AMR-CL adapter.
- What should I clean the plastic bowl with?
- Only water, kerosene or petroleum spirit. Petrol from a filling station, acetone and thinners damage polycarbonate.
Compressed air, inlet pressure 0–16 bar (metal bowl 0–25 bar), temperature 0 to +50 °C (metal bowl 0 to +90 °C). Zinc alloy body, NBR seals, polycarbonate or metal bowls, sintered bronze filter element.
Product sorting
List of products
A replacement sealing cone for the regulator valve of a size 2 COMBIBLOC unit. During maintenance, the cone is removed together with the element; its O-ring and guide pin are...
A replacement regulator diaphragm for a size 1 COMBIBLOC unit. If the regulator does not hold the set pressure or air escapes under the knob, a damaged diaphragm may be the cause.
A replacement sealing cone for the regulator valve of a size 1 COMBIBLOC unit. During maintenance, the cone is removed together with the element; its O-ring and guide pin are...
A replacement plastic lubricator sight dome for COMBIBLOC units of sizes 1 and 2. In the sight glass you count the drops. The plastic dome belongs with a unit with a plastic bowl.
A replacement 40 µm sintered bronze filter element for a size 1 COMBIBLOC unit. The same element is fitted in the unit as standard. It traps dirt and water droplets before the...
A replacement metal lubricator sight dome for COMBIBLOC units of sizes 1 and 2. In the sight glass you count the drops. The metal dome belongs with the metal bowl, which...
A replacement 40 µm sintered bronze filter element for a size 2 COMBIBLOC unit. The same element is fitted in the unit as standard. It traps dirt and water droplets before the...
A replacement regulator diaphragm for a size 2 COMBIBLOC unit. If the regulator does not hold the set pressure or air escapes under the knob, a damaged diaphragm may be the cause.
A replacement plastic bowl for a size 1 COMBIBLOC unit with a semi-automatic drain that releases condensate when the pressure drops, for example after shut-off. It suits places...
A bracket with screws for mounting a size 2 COMBIBLOC unit on a wall or in a machine frame. It screws onto the unit body; the unit then stands upright and the bowl can be...
A bracket with screws for mounting a size 1 COMBIBLOC unit on a wall or in a machine frame. It screws onto the unit body; the unit then stands upright and the bowl can be...
A replacement plastic bowl for a size 1 COMBIBLOC unit with an add-on float condensate drain with manual override. It suits continuous operation and larger amounts of...
A replacement plastic bowl for a size 2 COMBIBLOC unit with a semi-automatic drain that releases condensate when the pressure drops, for example after shut-off. It suits places...
A replacement plastic bowl for a size 1 COMBIBLOC unit with a built-in float drain that releases the condensate by itself as soon as it rises. It suits continuous operation,...
A float condensate drain with manual override. It screws on in place of the manual drain: directly onto a bowl with a G 1/8" thread, or onto a bowl with a 14 mm hole using the...
A replacement plastic bowl for a size 2 COMBIBLOC unit with a built-in float drain that releases the condensate by itself as soon as it rises. It suits continuous operation,...
An adapter for connecting the AMR add-on drain to a bowl with a 14 mm mounting hole. It lets you retrofit the AMR drain even to a bowl that has no G 1/8" thread.
A replacement metal bowl with sight glass for a size 1 COMBIBLOC unit, with an add-on float condensate drain. For more demanding environments with continuous operation. The...
A replacement metal bowl with sight glass for a size 2 COMBIBLOC unit, with an add-on float condensate drain. For more demanding environments with continuous operation. The...
A replacement plastic bowl for a size 2 COMBIBLOC unit with an add-on float condensate drain with manual override. It suits continuous operation and larger amounts of...
A metal guard for the plastic bowl of a size 1 COMBIBLOC unit. It protects the bowl from impact, and the level remains visible. It suits places where something could hit the...
A metal guard for the plastic bowl of a size 2 COMBIBLOC unit. It protects the bowl from impact, and the level remains visible. It suits places where something could hit the...