With a DN250 flange and a flow of 418,333 l/min at 7 bar, the BFP-2500 basic filter traps coarse solid contaminants larger than 3 µm and liquid water. Working pressure up to 16...
With a DN300 flange and a flow of 523,333 l/min at 7 bar, the BFP-3000 basic filter traps coarse solid contaminants larger than 3 µm and liquid water. Working pressure up to 16...
With a G 3" thread and a flow of 36,000 l/min at 7 bar, the HFP-200 basic filter traps solid contaminants larger than 3 µm and liquid water. Working pressure up to 50 bar.
With a G 3" thread and a flow of 46,000 l/min at 7 bar, the HFP-240 basic filter traps solid contaminants larger than 3 µm and liquid water. Working pressure up to 50 bar.
With a DN150 flange and a flow of 156,667 l/min at 7 bar, the BFB-0900 coarse filter traps coarse solid contaminants larger than 15 µm and protects the finer stages after it....
With a DN200 flange and a flow of 209,167 l/min at 7 bar, the BFB-1200 coarse filter traps coarse solid contaminants larger than 15 µm and protects the finer stages after it....
With a DN200 flange and a flow of 261,667 l/min at 7 bar, the BFB-1500 coarse filter traps coarse solid contaminants larger than 15 µm and protects the finer stages after it....
With a DN250 flange and a flow of 314,167 l/min at 7 bar, the BFB-1800 coarse filter traps coarse solid contaminants larger than 15 µm and protects the finer stages after it....
With a DN250 flange and a flow of 418,333 l/min at 7 bar, the BFB-2500 coarse filter traps coarse solid contaminants larger than 15 µm and protects the finer stages after it....
With a DN300 flange and a flow of 523,333 l/min at 7 bar, the BFB-3000 coarse filter traps coarse solid contaminants larger than 15 µm and protects the finer stages after it....
With a G 3" thread and a flow of 36,000 l/min at 7 bar, the HFB-200 coarse filter traps coarse solid contaminants larger than 15 µm and protects the finer stages after it....
With a G 3" thread and a flow of 46,000 l/min at 7 bar, the HFB-240 coarse filter traps coarse solid contaminants larger than 15 µm and protects the finer stages after it....
The MDHI 50 differential pressure gauge shows the pressure drop of the filter element on HF filters with pressures up to 50 bar. Range 0 to 1 bar, 2 × G 1/8" connection,...
The MDHI 50-K differential pressure gauge shows the pressure drop of the filter element on HF filters with pressures up to 50 bar. Range 0 to 1 bar, 2 × G 1/8" connection,...
With a DN150 flange and a flow of 156,667 l/min at 7 bar, the BFR-0900 dust filter traps solid particles larger than 1 µm and liquid water. Working pressure up to 16 bar, 6...
With a DN200 flange and a flow of 209,167 l/min at 7 bar, the BFR-1200 dust filter traps solid particles larger than 1 µm and liquid water. Working pressure up to 16 bar, 8...
With a DN200 flange and a flow of 261,667 l/min at 7 bar, the BFR-1500 dust filter traps solid particles larger than 1 µm and liquid water. Working pressure up to 16 bar, 10...
With a DN250 flange and a flow of 314,167 l/min at 7 bar, the BFR-1800 dust filter traps solid particles larger than 1 µm and liquid water. Working pressure up to 16 bar, 12...
With a DN250 flange and a flow of 418,333 l/min at 7 bar, the BFR-2500 dust filter traps solid particles larger than 1 µm and liquid water. Working pressure up to 16 bar, 16...
With a DN300 flange and a flow of 523,333 l/min at 7 bar, the BFR-3000 dust filter traps solid particles larger than 1 µm and liquid water. Working pressure up to 16 bar, 20...
With a G 3" thread and a flow of 36,000 l/min at 7 bar, the HFR-200 dust filter traps solid particles larger than 1 µm and liquid water. Working pressure up to 50 bar.
With a G 3" thread and a flow of 46,000 l/min at 7 bar, the HFR-240 dust filter traps solid particles larger than 1 µm and liquid water. Working pressure up to 50 bar.
Filter housing AAF-1000T — head and bowl without element, with a G 2" thread and a flow of 16,667 l/min at 7 bar. You choose the element of any stage separately.
Filter housing AAF-120T — head and bowl without element, with a G 3/4" thread and a flow of 2,000 l/min at 7 bar. You choose the element of any stage separately.
Filter housing AAF-1500T — head and bowl without element, with a G 2" thread and a flow of 25,000 l/min at 7 bar. You choose the element of any stage separately.
Filter housing AAF-1680T — head and bowl without element, with a G 2 1/2" thread and a flow of 28,000 l/min at 7 bar. You choose the element of any stage separately.
Filter housing AAF-198T — head and bowl without element, with a G 1" thread and a flow of 3,300 l/min at 7 bar. You choose the element of any stage separately.
Filter housing AAF-2160T — head and bowl without element, with a G 3" thread and a flow of 36,000 l/min at 7 bar. You choose the element of any stage separately.
Filter housing AAF-25T — head and bowl without element, with a G 1/4" thread and a flow of 417 l/min at 7 bar. You choose the element of any stage separately.
Filter housing AAF-2760T — head and bowl without element, with a G 3" thread and a flow of 46,000 l/min at 7 bar. You choose the element of any stage separately.
Filter housing AAF-30T — head and bowl without element, with a G 3/8" thread and a flow of 500 l/min at 7 bar. You choose the element of any stage separately.
Filter housing AAF-335T — head and bowl without element, with a G 1" thread and a flow of 5,583 l/min at 7 bar. You choose the element of any stage separately.
Filter housing AAF-35T — head and bowl without element, with a G 1/4" thread and a flow of 583 l/min at 7 bar. You choose the element of any stage separately.
Filter housing AAF-510T — head and bowl without element, with a G 1 1/2" thread and a flow of 8,500 l/min at 7 bar. You choose the element of any stage separately.
Filter housing AAF-60T — head and bowl without element, with a G 3/8" thread and a flow of 1,000 l/min at 7 bar. You choose the element of any stage separately.
Filter housing AAF-780T — head and bowl without element, with a G 1 1/2" thread and a flow of 13,000 l/min at 7 bar. You choose the element of any stage separately.
Filter housing AAF-78T — head and bowl without element, with a G 1/2" thread and a flow of 1,300 l/min at 7 bar. You choose the element of any stage separately.
With a DN150 flange and a flow of 156,667 l/min at 7 bar, the BFM-0900 fine pre-filter traps fine solid particles larger than 0.1 µm, water and oil aerosol; residual oil is...
With a DN200 flange and a flow of 209,167 l/min at 7 bar, the BFM-1200 fine pre-filter traps fine solid particles larger than 0.1 µm, water and oil aerosol; residual oil is...
With a DN200 flange and a flow of 261,667 l/min at 7 bar, the BFM-1500 fine pre-filter traps fine solid particles larger than 0.1 µm, water and oil aerosol; residual oil is...