High-pressure regulator HP NPT 1/4", 1-172 bar, inlet 414 bar, brass

Code: DR14-172HD
New
Not rated Rating details
€1 376,64 –5 %
Vysokotlaký regulátor tlaku HP NPT 1/4", 1-172 bar, vstup 414 bar, mosaz
€1 376,64 –5 % €1 307,81 / pcs €1 080,83 excl. VAT Measure price:
Stock (17 pcs)
Delivery to:
13.11.2026
Delivery options

AirCom HP series high-pressure regulator for gases, without secondary venting.

  • control range 1–172 bar, inlet pressure up to 414 bar
  • connection NPT 1/4", 2 gauge ports
  • brass body, PFA seat
  • without pressure gauges and without panel nut

Detailed information

Free shipping
Free shipping
For purchases over 5,000 CZK
We guarantee
We guarantee
Extended warranty and service
Discount voucher
Discount voucher
For every purchase
Return of goods within 14 days
Return of goods within 14 days
Completely at our expense

Product detailed description

The DR14-172HD high-pressure regulator reduces the gas pressure from a gas cylinder, a cylinder bundle or a high-pressure network – up to 414 bar – to an adjustable 1 to 172 bar. It is a piston regulator without secondary venting, with a body made of brass and a PFA valve seat.

It belongs to the series of HP high-pressure regulators by the manufacturer AirCom. It is supplied without pressure gauges and without a panel nut; the two NPT 1/4" ports for the inlet and outlet pressure gauges are sealed with plugs.

Specifications

ParameterValue
CodeDR14-172HD
ManufacturerAirCom, HP series
Control range1–172 bar
Inlet pressuremax. 414 bar (oxygen max. 200 bar)
Flow rate2,800 l/min at an inlet of 414 bar and an outlet of 172 bar
ConnectionNPT 1/4" inlet and outlet, 2 × NPT 1/4" for pressure gauges
Controlpiston
Deviation when the inlet changes by 7 bar< 250 mbar
Secondary ventingno
Mediumcompressed air, nitrogen, oxygen (inlet max. 200 bar), hydrogen, helium
Operating temperature−25 to +75 °C
Materialbody brass, internal parts stainless steel, spring housing nickel-plated brass, knob PA, seat PFA, seals FKM
Dimensions50 × 137 mm, port axis 13 mm above the base
Panel mountinghole ⌀ 34 mm, panel thread UN 1 5/16"-20
Scope of deliveryregulator, plugs for the gauge ports
Weight1.2 kg

Which gases, and how to use them safely

Connection diagram of an HP high-pressure regulator with inlet filter, pressure gauges and safety valve
1 gas source – cylinder bundle, cylinder or network, 2 inlet filter (recommended by the manufacturer), 3 HP regulator with gauges for inlet pressure p₁ and outlet pressure p₂ (NPT 1/4" ports), 4 separate safety valve downstream of the regulator, 5 consumer. According to the AirCom operating instructions.

The manufacturer specifies the regulator for compressed air, nitrogen, oxygen (inlet pressure no more than 200 bar), hydrogen and helium. Safety instructions of the manufacturer AirCom:

  • never use oils or greases on gas regulators – they ignite easily and react violently with some compressed gases
  • do not use any lubricant during installation – the regulator becomes contaminated, and with oxygen there is a risk of fire
  • protect the connected equipment against overpressure with a separate safety valve – the regulator has no secondary venting and cannot protect it by itself
  • only instructed personnel may work with flammable, pyrophoric and toxic gases; provide ventilation and gas leak detectors
  • the regulator is neither a shut-off valve nor a flow regulator – shut off the gas with the cylinder valve or a shut-off valve in the network

Dimensions and panel mounting

Dimensional drawing of the HP high-pressure regulator DR14-172HD
A 50 mm, B 137 mm, C 13 mm, panel hole ⌀ 34 mm

The regulator is 50 mm wide and 137 mm high; the axis of the ports is 13 mm above the base. You fix it in a panel through a ⌀ 34 mm hole with the SM DR 14 HD panel nut.

Installation and adjustment

Mounting an HP high-pressure regulator in a panel with the panel nut: section through the panel and ⌀ 34 mm hole
1 panel with ⌀ 34 mm hole, 2 regulator body behind the panel, 3 panel nut UN 1 5/16"-20 (ordered separately), 4 knob. According to the AirCom catalogue.
  • blow out all pipes before installation – dirt will damage the valve seat
  • before connecting, loosen the knob anticlockwise so that the spring is not under tension
  • connect the regulator according to the arrow on the body – from inlet IN to outlet OUT; any mounting position is possible
  • the internal filter only provides protection during installation – the manufacturer recommends a filter at the inlet; the gas should be dry so that the regulator does not ice up at high flow rates
  • set the pressure from below, always fine-tune towards a higher pressure; do not turn the knob beyond the upper limit of the range
  • screw in pressure gauges with NPT 1/4" connections in place of the plugs – the left one for inlet pressure and the right one for outlet pressure

Accessories

  • panel nut UN 1 5/16"-20: SM DR 14 HD
  • the same range with a stainless steel body: DR14-172HDES
  • protection of equipment downstream of the regulator: safety valves

For an air or nitrogen network up to 200 bar with pressure gauges included, there are regulators 120; for connection directly to a cylinder, cylinder pressure regulators.

Additional parameters

Category: High-pressure regulators HP for gases with inlet up to 414 bar
EAN: 4050571825096
Pressure: 414 bar
Dimensions: 50 × 137 mm
Weight: 1,2 kg
Material: Brass
Medium: Compressed air, Nitrogen, Oxygen, Helium, Hydrogen
Working temperature: -25 / +75 °C
Flow: 2,800 l/min
Regulatory range: 1.0 to 172 bar
Product type: Pressure regulator
Thread: NPT 1/4"
Regulator type: Manually adjusted
Outlet pressure: 0.1–1 bar, 1–3 bar, 3–6 bar, 6–10 bar, 10–16 bar, 16–25 bar, 25–50 bar, 50–150 bar, 150–300 bar
Pressure gauge included: No, port only

Product rating

Be the first who will post an article to this item!

Do not fill out this field

How would you rate this product? Choose 1 to 5 stars, where 1 is the worst and 5 is the best rating.

Security check

By submitting your review you agree to the privacy policy

AirCom Pneumatic GmbH from Ratingen, Germany, is a specialist in pressure and flow control of gases and liquids. Its range includes pressure regulators from miniature to high-pressure, precision and proportional regulators, compressed air treatment, pressure switches and pressure transmitters.

From AirCom we offer RPM low-pressure regulators, which hold a constant pressure from 5 to 1500 mbar, DRPA proportional pressure regulators, which set a pressure of 0 to 16 bar according to an electric signal of 0–10 V or 4–20 mA, and HP high-pressure regulators with an inlet pressure of up to 414 bar. Plus a mounting bracket for the RPM 12 and software for setting up the DRPA.

AirCom regulators shown to scale: RPM 10 with T-handle, RPM 12, proportional DRPA G 1/2" and G 1/8"From 5 mbar to 172 bar
5 mbarlowest RPM setting
9,600 l/minflow of the RPM 10 with T-handle
0–16 barDRPA pressure set by signal
414 barhighest HP inlet pressure

AirCom regulators and accessories

AirCom RPM 12 low-pressure regulator with handwheel

RPM 12 with handwheel

From 5 to 1500 mbar. Low-pressure regulator with G 1/2" connection for a constant pressure in millibars.

  • ranges 5–45, 10–400, 20–1000 and 50–1500 mbar
  • flow 1,000 l/min, inlet 1 to 15 bar
  • pressure gauge ⌀ 63 mm included
View regulator
AirCom RPM 10 low-pressure regulator with adjusting screw

RPM 10 with adjusting screw

From 5 to 400 mbar. Low-pressure regulator with G 1" connection for fine setting of low pressures.

  • ranges 5–45, 10–120 and 10–400 mbar
  • flow 1,400 l/min, Kv 1.4 m³/h
  • adjusting screw with lock nut
View regulator
AirCom RPM 10 low-pressure regulator with T-handle

RPM 10 with T-handle

Flow 9,600 l/min. G 1" low-pressure regulator with a larger valve for high air consumption.

  • ranges 15–700 and 200–1200 mbar
  • flow coefficient Kv 8.4 m³/h
  • T-handle with lock nut
View regulator
AirCom DRPA G 1/8" proportional pressure regulator

DRPA G 1/8"

Flow 210 l/min. The smallest proportional regulator of the series: it sets the pressure according to an electric signal.

  • ranges 0–6 and 0–10 bar
  • signal 0–10 V or 4–20 mA
  • brass body, 35 × 83 × 57 mm
View regulator
AirCom DRPA G 1/4" proportional pressure regulator

DRPA G 1/4"

Flow 700 l/min. Proportional pressure regulator for ranges up to 0–16 bar.

  • ranges 0–6, 0–10 and 0–16 bar
  • signal 0–10 V or 4–20 mA
  • brass body, 52 × 105 × 68 mm
View regulator
AirCom DRPA G 1/2" proportional pressure regulator

DRPA G 1/2"

Flow 1,400 l/min. The largest proportional regulator of the series, for high flow.

  • ranges 0–10 and 0–12 bar
  • signal 0–10 V or 4–20 mA
  • aluminium body, 70 × 136 × 85 mm
View regulator
AirCom HP high-pressure regulator

HP high-pressure regulators

Inlet up to 414 bar. Compact regulators for gases including oxygen, hydrogen and helium, in brass or stainless steel.

  • outlet 0.1 to 172 bar
  • NPT 1/4", without pressure gauges
  • panel mounting possible
View regulator
DRPA ANALYSE software for setting up AirCom DRPA proportional regulators (illustration)

DRPA ANALYSE software

Set-up from a PC. Software with RS-232 converter for DRPA proportional regulators.

  • shows set and actual pressure
  • zero point, range, ramp, P, PI, PID control
  • recording of the control process and diagnostics
View software
AirCom RPM W stainless steel mounting bracket for RPM 12 regulators

RPM W bracket

For the RPM 12. Mounting bracket for fixing the RPM 12 regulator to a wall or frame.

  • stainless steel
  • 152 × 90 × 41 mm
  • holes ⌀ 6.5 mm and slots 9 mm
View bracket

Not sure which regulator to choose? The overview of pressure regulators also includes regulators with a pressure gauge, precision and pilot-operated series.

All pressure regulators

AirCom regulators at a glance

RPM low-pressure regulators, DRPA proportional pressure regulators and HP high-pressure regulators
SeriesConnectionRegulationFlowOperation
RPM 12G 1/2"5–45 / 10–400 / 20–1000 / 50–1500 mbar1,000 l/minhandwheel
RPM 10G 1"5–45 / 10–120 / 10–400 mbar1,400 l/minadjusting screw
RPM 10G 1"15–700 / 200–1200 mbar9,600 l/minT-handle
DRPAG 1/8"0–6 / 0–10 bar210 l/minsignal 0–10 V or 4–20 mA
DRPAG 1/4"0–6 / 0–10 / 0–16 bar700 l/minsignal 0–10 V or 4–20 mA
DRPAG 1/2"0–10 / 0–12 bar1,400 l/minsignal 0–10 V or 4–20 mA
HPNPT 1/4"0.1–1.7 to 1–172 bar500–2,800 l/min (at full inlet pressure)knob

RPM: inlet pressure 1 to 15 bar, flow according to the manufacturer at 6 bar inlet and the highest outlet pressure of the range, pressure gauge ⌀ 63 mm included. DRPA: inlet pressure max. 12 bar (0–12 bar range 14 bar, 0–16 bar 18 bar), flow at 6 bar inlet and 5 bar outlet, 24 V DC supply, M12 connector; the 0–6 bar range only with a 0–10 V signal.

How to choose and connect an AirCom regulator

1. Manual or electric setting

An RPM regulator holds a constant low pressure that you set once by hand. If the machine control system is to change the pressure, choose a DRPA proportional regulator.

2. Range and size

Choose the smallest range that your pressure fits into – the setting will be finer. Choose the size by the flow in the table above. Mind the units: 1 bar = 1,000 mbar.

3. Prepare the air

Install a compressed air filter upstream of the regulator. The DRPA works with lubricated and non-lubricated air filtered to 50 µm; keep the inlet pressure at least 10 % above the highest pressure to be set.

4. Connect and set

Connect the regulator according to the arrow on the body. On the RPM always set the pressure upwards and lock it with the lock nut. Connect the DRPA via the M12 connector to the 24 V DC supply and the control signal.

Frequently asked questions

What is the difference between RPM and DRPA?
The RPM holds a constant low pressure from 5 to 1500 mbar that you set by hand. The DRPA sets a pressure of 0 to 16 bar according to an electric signal from the control system and constantly monitors the outlet pressure with a sensor.
Does the RPM regulator come with a pressure gauge?
Yes, a ⌀ 63 mm pressure gauge with a scale matching the range is included. It screws into one of the two G 1/4" side ports.
Do I need software for the DRPA?
No, the regulator is factory-set. The software with RS-232 converter is useful if you want to change the zero point, range, ramp or control parameters, monitor the pressure curve or troubleshoot.
What does the DRPA do if the signal or supply fails?
It exhausts the outlet. It fills and exhausts the outlet with the same flow and consumes no air itself.
What does the manufacturer call these regulators?
The RPM 12 corresponds to type AirCom R161-04, the RPM 10 to type R160-08 and the DRPA to the PP series (proportional regulators with digital control). The full RPM type designation is on each regulator’s product page.
Where can I find all regulators?
RPM regulators are in the category RPM low-pressure regulators, DRPA in the category proportional pressure regulators – together with other proportional regulators.

Technical data according to the catalogues of the manufacturer AirCom Pneumatic GmbH (Ratingen, Germany).

Manufacturing company : AirCom Pneumatic GmbH
Address : Siemensstraße 18, 40885 Ratingen, Germany
E-mail : info@aircom.net