Compressed air filtration pressure 16 to 64 bar
A series of compressed air filters manufactured by the renowned manufacturer Omega Air, working with pressures from 16 to 64 bar, are used for effective removal of solid impurities, oil, water, hydrocarbons and even odours. Filtration capability with solids purity in the range of 15 um - 0.005 um. Operating temperature of the filtration medium from +1.5°C to +65°C. Choose from AF, BF, CF, HF filtration with different working pressures and threaded or flanged connections.
Product sorting
List of products
Electronic pressure gauge designed to check and monitor the condition of the filter cartridge. The condition of the filter cartridge is determined by the pressure gradient, the...
Electronic pressure gauge designed to check and monitor the condition of the filter cartridge. The condition of the filter cartridge is determined by the pressure gradient, the...
Simple mechanical device for checking the condition of the filter cartridge. Contributes to reducing power consumption by alerting to high pressure gradients. If the filter...
AFM filters are used to remove the largest mechanical impurities from compressed air up to 0.1 um according to ISO 8573-1 class 2. Body with easily removable container and...
MDM40 - basic version. Magnetic differential pressure gauges for displaying the orientation state of the filter cartridge. Fitted with dial with indicative scale and green/red...
AAFC cyclone separator in 1/2" design with a flow rate of 1,300 l/min for partial removal of condensate from compressed air. Here the flow changes to rotational and due to the...
The AFS microfilter is used to remove the largest mechanical impurities from compressed air up to 0.01 um according to ISO 8573-1 class 1. Body with easily removable container...
Replacement cyclone cartridge for liquid water filtration AAFC-78V. Recommended replacement 12 months or every 4,000 MH and upon indication of clogging of the filter element by...
The filters are used to remove the largest mechanical impurities from compressed air up to 1 um according to ISO 8573-1 class 3. Body with easily removable container and...
Basic AFP filters according to ISO 8573.1 with a filtration capacity of 3 um and an efficiency of 99.9%. FPRO filters are used to remove the largest mechanical impurities from...
AAFS 1 1/2" microfilter to remove micro impurities up to 0.01 um from compressed air according to ISO 8573-1 class 1. Body with easily removable container and designed for a...
Replacement cyclone insert for liquid water filtration AAFC-120V. Recommended replacement 12 months or every 4,000 MH and upon indication of clogging of the filter element by...
Replacement fine filter cartridge with 0.1 µm filtration capacity for OMEGA AIR AAFM-25 and AAFM-30 pre-filters. Recommended replacement 12 months or every 4,000 MH and when...
Replacement cyclone cartridge for liquid water filtration AAFC-198V. Recommended replacement 12 months or every 4,000 MH and upon indication of clogging of the filter element by...
AAFC cyclone separator in 3/8" design with a flow rate of 1,000 l/min for partial removal of condensate from compressed air. Here the flow changes to rotational and due to the...
The set allows the combination of 2 filters with different filtration capabilities into one block. Reduction of space required for installation. For filtration sizes AF-33 to...
Replacement cyclone cartridge for liquid water filtration AAFC-510V. Recommended replacement 12 months or every 4,000 MH and upon indication of clogging of the filter element by...
The set allows the combination of 3 filters with different filtration capabilities into one block. Reduction of space required for installation. For filtration sizes AF-33 to...
Replacement cyclone insert for liquid water filtration AAFC-1000V. Recommended replacement 12 months or every 4,000 MH and upon indication of clogging of the filter element by...
Replacement microfilter cartridge with filtration capacity of 0.01 µm for OMEGA AIR AAFS-25 and AAFS-30 microfilters. Recommended replacement 12 months or every 4,000 MH and...
Replacement cyclone cartridge for liquid water filtration AAFC-1500V. Recommended replacement 12 months or every 4,000 MH and upon indication of clogging of the filter element...
Replacement sintered bronze 15 µm filter cartridge for OMEGA AIR AAFB-120 filter. Recommended replacement 12 months or every 4,000 MH and when clogging of the filter cartridge...
Magnetic differential pressure gauges to indicate the pressure gradient of the filter cartridge. MDM60E - equipped with LED signalling when the insert is dropped. Designed for...
Wall mounting kit. The set consists of angles that are attached to the edges of the filter and allow subsequent mounting on the wall. Fast and elegant installation that everyone...
The simplest way to drain condensate from pressure vessels and filter vessels. Connection by thread, control of the firing by a rotary pin.
Connection set for easy connection of two or more filters into one block in 1/2" threaded design. Universal design allowing the connection of filters from different...
Replacement sintered bronze filter cartridge 15 µm for OMEGA AIR filter AAFB-198. Recommended replacement 12 months or every 4,000 MH and when clogging of the filter cartridge...
AAFS 1/4" microfilter for removal of micro impurities up to 0.01 um from compressed air according to ISO 8573-1 class 1. Body with easily removable container and designed for a...
Replacement fine filter cartridge with 0.1 µm filtration capacity for OMEGA AIR AAFM-780 pre-filter. Recommended replacement 12 months or every 4,000 MH and when clogging of the...
AAFR dust filter in 3/8" design to remove dust impurities up to 1 um from compressed air according to ISO 8573-1 class 3. Body with easily removable container and designed for a...
Wall mounting kit. The set consists of angles that are attached to the edges of the filter and allow subsequent mounting on the wall. Fast and elegant installation that everyone...
AAFS 2" microfilter for removal of micro impurities up to 0.01 um from compressed air according to ISO 8573-1 class 1. Body with easily removable container and designed for a...
Replacement microfiltration cartridge with filtration capacity of 0.01 µm for OMEGA AIR AAFS-335 microfilters. Recommended replacement 12 months or every 4,000 MH and when...
Replacement fine filter cartridge with 0.1 µm filtration capacity for OMEGA AIR AAFM-1500 and AAFM-1680 pre-filters. Recommended replacement 12 months or every 4,000 MH and when...
AAFA activated carbon filter in 3/8" version for absorption of residual oil, oil vapours and aerosols with < 0,005 mg/m3 from compressed air according to ISO 8573-1 class 1....
AAFC cyclone separator in 3/4" design with a flow rate of 2,000 l/min for partial removal of condensate from compressed air. Here the flow changes to rotational and due to the...
Replacement sintered bronze 15 µm filter cartridge for OMEGA AIR AAFB-78 filter. Recommended replacement 12 months or every 4,000 MH and when clogging of the filter cartridge is...
Connection set for easy connection of two or more filters into one block in 3/4" threaded design. Universal design allowing the connection of filters from different...
Connection set for easy connection of two or more filters into one block in 3/8" threaded design. Universal design allowing the connection of filters from different...
The HFS filter insert removes mechanical impurities and oil from the compressed air. Borosilicate microfibre insert with a filtration capacity of up to 0.01 μm. Working pressure...