Compressed air filtration pressure 16 to 64 bar
A series of compressed air filters manufactured by the renowned manufacturer Omega Air, working with pressures from 16 to 64 bar, are used for effective removal of solid impurities, oil, water, hydrocarbons and even odours. Filtration capability with solids purity in the range of 15 um - 0.005 um. Operating temperature of the filtration medium from +1.5°C to +65°C. Choose from AF, BF, CF, HF filtration with different working pressures and threaded or flanged connections.
Product sorting
List of products
Simple mechanical device for checking the condition of the filter cartridge. Contributes to reducing power consumption by alerting to high pressure gradients. If the filter...
AAFR dust filter in 3/8" design to remove dust impurities up to 1 um from compressed air according to ISO 8573-1 class 3. Body with easily removable container and designed for a...
Designed to accurately display the pressure gradient value of the filter cartridge. Dial with coloured fields - red to indicate both wear and tear of the insert. Optimized...
AAFC cyclone separator in 3/4" design with a flow rate of 2,000 l/min for partial removal of condensate from compressed air. Here the flow changes to rotational and due to the...
AAFP basic filter in 3/4" design for removal of basic mechanical impurities up to 3 um from compressed air according to ISO 8573-1 class 6. Body with easily removable container...
AAFP basic filter in 1 1/2" design for removal of basic mechanical impurities up to 3 um from compressed air according to ISO 8573-1 class 6. Body with easily removable...
AAFC 2" cyclone separator with a flow rate of 16,667 l/min for partial removal of condensate from compressed air. Here the flow changes to rotational and due to the rotation and...
Float-operated condensate drain valve for compressed air systems up to 13 bar. Version AOK13PA for external mounting on the filter body with 1/2" thread.
Replacement cyclone cartridge for liquid water filtration AAFC-78V. Recommended replacement 12 months or every 4,000 MH and upon indication of clogging of the filter element by...
Replacement cyclone cartridge for liquid water filtration AAFC-60V. Recommended replacement 12 months or every 4,000 MH and upon indication of clogging of the filter element by...
Replacement cyclone insert for liquid water filtration AAFC-120V. Recommended replacement 12 months or every 4,000 MH and upon indication of clogging of the filter element by...
Replacement cyclone cartridge for liquid water filtration AAFC-198V. Recommended replacement 12 months or every 4,000 MH and upon indication of clogging of the filter element by...
Replacement fine filter cartridge with 0.1 µm filtration capacity for OMEGA AIR AAFM-25 and AAFM-30 pre-filters. Recommended replacement 12 months or every 4,000 MH and when...
AAFS 1/4" microfilter for removal of micro impurities up to 0.01 um from compressed air according to ISO 8573-1 class 1. Body with easily removable container and designed for a...
Replacement microfiltration cartridge with filtration capacity 0,01 µm for OMEGA AIR AAFS-780 microfilters. Recommended replacement 12 months or every 4,000 MH and when clogging...
Replacement dust filter cartridge with 1 µm filtration capacity for OMEGA AIR AAFR-25 and AAFR-30 filters. Recommended replacement 12 months or every 4,000 MH and when clogging...
AAFS 1/2" microfilter to remove micro impurities up to 0.01 um from compressed air according to ISO 8573-1 class 1. Body with easily removable container and designed for a flow...
Replacement microfiltration cartridge with filtration capacity of 0.01 µm for OMEGA AIR AAFS-335 microfilters. Recommended replacement 12 months or every 4,000 MH and when...
Replacement microfiltration cartridge with filtration capacity 0,01 µm for OMEGA AIR AAFS-510 microfilters. Recommended replacement 12 months or every 4,000 MH and when clogging...
AAFC cyclone separator in 1" design with a flow rate of 3,300 l/min for partial removal of condensate from compressed air. Here the flow changes to rotational and due to the...
AAFS 1" microfilter to remove micro impurities up to 0.01 um from compressed air according to ISO 8573-1 class 1. Body with easily removable container and designed for a flow...
AAFS microfilter in 3" design to remove micro impurities up to 0.01 um from compressed air according to ISO 8573-1 class 1. Body with easily removable container and designed for...
Microfilter AAFS in 1/2" design to remove micro impurities down to 0.01 um from compressed air according to ISO 8573-1 class 1. Body with easily removable bowl and designed for...
AAFC cyclone separator in 3/8" design with a flow rate of 1,000 l/min for partial removal of condensate from compressed air. Here the flow changes to rotational and due to the...
AAFS 1" microfilter to remove micro impurities up to 0.01 um from compressed air according to ISO 8573-1 class 1. Body with easily removable container and designed for a flow...
Replacement microfiltration cartridge with filtration capacity of 0.01 µm for OMEGA AIR AAFS-2160 microfilters. Recommended replacement 12 months or every 4,000 MH and when...
Replacement microfilter cartridge with filtration capacity of 0.01 µm for OMEGA AIR AAFS-1500 and AAFS-1680 microfilters. Recommended replacement 12 months or every 4,000 MH and...
Replacement microfilter cartridge with filtration capacity of 0.01 µm for OMEGA AIR AAFS-1000 microfilters. Recommended replacement 12 months or every 4,000 MH and when clogging...
Electronic condensate drain from a compressed air system up to 16 bar, operating on a timed valve switching. External mounting on the filter body using a 1/2" thread. Simple...
AAFM pre-filter in 3/8" design for removal of fine impurities up to 0.1 um from compressed air according to ISO 8573-1 class 2. Body with easily removable container and designed...
Replacement cyclone cartridge for liquid water filtration AAFC-510V. Recommended replacement 12 months or every 4,000 MH and upon indication of clogging of the filter element by...
Replacement cyclone insert for liquid water filtration AAFC-1000V. Recommended replacement 12 months or every 4,000 MH and upon indication of clogging of the filter element by...
Replacement cyclone cartridge for liquid water filtration AAFC-1500V. Recommended replacement 12 months or every 4,000 MH and upon indication of clogging of the filter element...
Replacement microfilter cartridge with filtration capacity of 0.01 µm for OMEGA AIR AAFS-25 and AAFS-30 microfilters. Recommended replacement 12 months or every 4,000 MH and...
The set allows the combination of 2 filters with different filtration capabilities into one block. Reduction of space required for installation. For filtration sizes AF-33 to...
AAFA activated carbon filter in 3/8" version for absorption of residual oil, oil vapours and aerosols with < 0,005 mg/m3 from compressed air according to ISO 8573-1 class 1....
The set allows the combination of 3 filters with different filtration capabilities into one block. Reduction of space required for installation. For filtration sizes AF-33 to...
Replacement cyclone cartridge for liquid water filtration AAFC-2160V. Recommended replacement 12 months or every 4,000 MH and upon indication of clogging of the filter element...
AFM filters are used to remove the largest mechanical impurities from compressed air up to 0.1 um according to ISO 8573-1 class 2. Body with easily removable container and...
AAFR dust filter in 2" design to remove dust impurities up to 1 um from compressed air according to ISO 8573-1 class 3. Body with easily removable container and designed for a...