Replacement basic filter cartridge with 3 µm filtration capacity for OMEGA AIR AAFP-2760 filter. Recommended replacement 12 months or every 4,000 MH and when clogging of the...
AAFP basic filter in 1 1/2" design for removal of basic mechanical impurities up to 3 um from compressed air according to ISO 8573-1 class 6. Body with easily removable...
Replacement basic filter cartridge with 3 µm filtration capacity for OMEGA AIR AAFP-35 and AAFP-60 filters. Recommended replacement 12 months or every 4,000 MH and when clogging...
AAFR dust filter in 2 1/2" design to remove dust impurities up to 1 um from compressed air according to ISO 8573-1 class 3. Body with easily removable container and designed for...
AAFR dust filter in 3" design to remove dust impurities up to 1 um from compressed air according to ISO 8573-1 class 3. Body with easily removable container and designed for a...
AAFR dust filter in 3" design to remove dust impurities up to 1 um from compressed air according to ISO 8573-1 class 3. Body with easily removable container and designed for a...
Replacement basic filter cartridge with 3 µm filtration capacity for OMEGA AIR AAFP-335 filter. Recommended replacement 12 months or every 4,000 MH and when clogging of the...
Replacement dust filter cartridge with 1 µm filtration capacity for OMEGA AIR AAFR-2760. Recommended replacement 12 months or every 4,000 MH and when clogging of the filter...
AAFR dust filter in 1 1/2" design to remove dust impurities up to 1 um from compressed air according to ISO 8573-1 class 3. Body with easily removable container and designed for...
AAFP basic filter in 3/4" design for removal of basic mechanical impurities up to 3 um from compressed air according to ISO 8573-1 class 6. Body with easily removable container...
AAFP basic filter in 1 1/2" design for removal of basic mechanical impurities up to 3 um from compressed air according to ISO 8573-1 class 6. Body with easily removable...
AAFP basic filter in 2" design to remove basic mechanical impurities up to 3 um from compressed air according to ISO 8573-1 class 6. Body with easily removable container and...
AAFP basic filter in 3" design to remove basic mechanical impurities up to 3 um from compressed air according to ISO 8573-1 class 6. Body with easily removable container and...
Dust filter AAFR in 1/4" design to remove dust impurities up to 1 um from compressed air according to ISO 8573-1 class 3. Body with easily removable container and designed for a...
Removes mechanical contaminants up to 1 um in size according to ISO 8573-1 class 3. Connection with internal pipe threads 1 1/2". The design allows a flow rate of up to 6667...
Removes mechanical contaminants up to 1 um in size according to ISO 8573-1 class 3. Connection with internal pipe threads 1 1/2". The design allows a flow rate of up to 4700...
Removes mechanical contaminants up to 1 um in size according to ISO 8573-1 class 3. Connection by internal pipe threads 1". The design allows a flow rate of up to 3400 l/min....
Removes mechanical contaminants up to 1 um in size according to ISO 8573-1 class 3. Connection with 2" internal pipe threads. The design allows a flow rate of up to 13,317...
Removes mechanical contaminants up to 1 um in size according to ISO 8573-1 class 3. Connection with 2" internal pipe threads. The design allows a flow rate of up to 8233 l/min....
Removes mechanical contaminants up to 1 um in size according to ISO 8573-1 class 3. Connection with 3/4" internal pipe threads. The design allows a flow rate of up to 1867...
The BFR dust filter insert is used to remove mechanical impurities from compressed air. Acrylic fibre and cellulose liner with a filtration capacity of up to 1 μm. Working...
The filters are used to remove the smallest mechanical impurities from compressed air up to 1 um according to ISO 8573-1 class 3. Connection by flange with DN80 clearance....
The filters are used to remove the smallest mechanical impurities from compressed air up to 1 um according to ISO 8573-1 class 3. Connection by flange with DN100 clearance. The...
The filters are used to remove the smallest mechanical impurities from compressed air up to 1 um according to ISO 8573-1 class 3. Connection by flange with DN125 clearance....
The filters are used to remove the smallest mechanical impurities from compressed air up to 1 um according to ISO 8573-1 class 3. Connection by flange with DN150 clearance....
Replacement basic filter cartridge with 3 µm filtration capacity for OMEGA AIR AAFP-510 filter. Recommended replacement 12 months or every 4,000 MH and when clogging of the...
Replacement basic filter cartridge with 3 µm filtration capacity for OMEGA AIR AAFP-78 filter. Recommended replacement 12 months or every 4,000 MH and when clogging of the...