With a G 1 1/2" thread and a flow of 4,700 l/min at 7 bar, the HFC-047 cyclone separator removes liquid water, oil and coarse contaminants directly after the compressor. Working pressure up to 50 bar.

Detailed information

Free shipping
Free shipping
For purchases over 5,000 CZK
We guarantee
We guarantee
Extended warranty and service
Discount voucher
Discount voucher
For every purchase
Return of goods within 14 days
Return of goods within 14 days
Completely at our expense

Product detailed description

The HFC-047 cyclone separator removes liquid water, oil and coarse solid contaminants from compressed air. It separates them by centrifugal force, without a filter element. It has a G 1 1/2" thread, a flow of 4,700 l/min at 7 bar and a working pressure of up to 50 bar.

It belongs to the range of Omega Air HF filters up to 50 bar: the housing is the same as on these filters, but instead of a filter element it contains a cyclone element.

Specifications

ParameterValue
ConnectionG 1 1/2" (female pipe thread)
Flow at 7 bar4,700 l/min (282 Nm³/h)
Working pressure50 bar
Working temperature+1.5 to +65 °C
Principlecentrifugal separation of liquid water and oil, without a filter element
Spare cyclone elementHFC-047V
Housingcast aluminium with powder coating
Dimensions A × B × C × D535 × 160 × 45 × 260 mm
Weight9.5 kg
Condensate drainordered separately
Condensate outletG 1/2" opening at the bottom

Housing and dimensions

Drawing of the HF housing with dimensions A, B, C and D
A overall height, B head width, C from the top edge to the connection axis, D clearance below the separator.

Housing: cast aluminium with powder coating. The air is connected through female pipe threads in the head; the condensate leaves through a G 1/2" opening at the bottom. Dimensions according to the manufacturer: 535 × 160 × 45 × 260 mm, weight 9.5 kg.

Flow by pressure

The flow applies to a pressure of 7 bar and a temperature of +20 °C. At a different pressure, it is multiplied by the manufacturer’s correction factor:

Pressure (bar)35710131620304050
Flow (l/min)2,3503,5254,7006,4868,22510,01112,36118,23624,11129,986

Cyclone element and accessories

The separator collects a lot of water, so it needs a condensate drain, which is ordered separately. Suitable drains: AOK50B and AOK50SS. The spare cyclone element is listed in the specifications table.

Where to place it

It goes after the compressor or aftercooler, before the HF filters. It traps liquid water and oil before they reach the filters, so the filter elements clog less.

You will find all sizes and pressures among the HFC cyclone separators.

Additional parameters

Category: Cyclone water separators for compressed air
Pressure: 50 bar
Connecting: 1 1/2"
Dimensions: 535 × 160 × 45 × 260 mm
Weight: 9.5 kg
Filter insert: CKLHF-047V
Material: Aluminium
Working temperature: +1.5 / +65°C
Flow: 4,700 l/min
Product type: Cyclone separator
Filtration stage: Cyclone separator
Connection type: Female thread
Version: Cyclone separator CKLHF
Pressure: 50 bar
Connecting: 1 1/2"
Dimensions: 535 x 160 x 45 x 260 mm
Weight: 9.5 kg
Filter insert: CKLHF-047V
Material: Aluminium
Working temperature: +1.5 / +65°C
Flow: 4,700 l/min

Product rating

Be the first who will post an article to this item!

Do not fill out this field

How would you rate this product? Choose 1 to 5 stars, where 1 is the worst and 5 is the best rating.

Security check

By submitting your review you agree to the privacy policy

Omega Air is a Slovenian manufacturer of compressed air treatment equipment based in Ljubljana. Founded in 1988, the company now has 370 employees and exports to more than 80 countries. It has its own development team and patents and carries out almost all production in its own facilities.

We mainly offer industrial filters up to 420 bar with replacement elements, stainless steel process and sterile filters, refrigeration, desiccant and membrane dryers, activated carbon columns, oil-water separators and condensate drains. They are used in workshops and large plants, in food, pharmaceuticals, chemicals and paint shops.

Omega Air AAF filter, IHP and WFIT stainless steel filters with elements, ADRY desiccant dryer and RDS refrigeration dryerSlovenian manufacturer
1988year the Slovenian company was founded
80+countries Omega Air exports to
420 barhighest pressure of CHP and IHP filters
0.01 µmmicrofilter and sterile element

Omega Air filters, dryers and separators

Omega Air AAF compressed air filter

Industrial filters up to 50 bar

Filters for standard air lines. AAF and BF ranges up to 16 bar, BFHP up to 25 bar and HF up to 50 bar. The element sets the filtration grade.

  • from coarse filter to activated carbon
  • G 1/8" to 3" thread or DN80 to DN300 flanges
  • AAFHT for hot air up to +120 °C
View filters
Omega Air IHP stainless steel high-pressure filter with element

CHP and IHP high-pressure filters

For 100, 250 and 420 bar. CHP housings are nickel-plated carbon steel, IHP housings stainless steel.

  • 8 sizes with G 1/4" to 2" thread
  • flow 667 to 11,917 l/min at 7 bar
  • six grades up to activated carbon
View filters
Omega Air HPF stainless steel process filter with element

Stainless steel process filters

1.4404 stainless steel for food and pharma. Six ranges up to 14 and 50 bar with thread, flanges or welding ends.

  • 12 filtration grades in each range
  • sterile element in the PF and HPF ranges
  • flow 1,250 to 352,000 l/min at 7 bar
View filters
Omega Air refrigeration dryer for compressed air

RDS refrigeration dryers

Dew point +3 °C for most plants. The air cools down in the dryer, water condenses and the drain removes it without losing air.

  • 18 sizes, 333 to 31,667 l/min
  • working pressure up to 16 bar
  • controller shows the dew point
View dryers
Omega Air ADRY desiccant dryer with inlet and outlet filter

ADRY desiccant dryers

Very dry air, dew point −40 °C. Moisture is captured by desiccant in two alternating columns.

  • 9 sizes, 6 to 200 Nm³/h
  • dew point −25 or −70 °C on request
  • inlet and outlet filter included
View dryers
Omega Air MADRY membrane dryer with filters

MADRY membrane dryers

They dry without electricity. Water vapour passes through the wall of hollow fibres, dry air stays inside.

  • 12 sizes, 50 to 3,000 l/min
  • dew point down to −40 °C, up to 12 bar
  • fine pre-filter and microfilter included
View dryers
Omega Air TAC activated carbon column

TAC activated carbon columns

They capture oil vapours that filters let through. The air flows through a bed of granular activated carbon.

  • outlet oil below 0.003 mg/m³
  • 19 sizes, 6 to 1,200 Nm³/h
  • up to 16 bar, high-pressure TACHP up to 420 bar
View columns
Omega Air WOS oil-water separators in four sizes

WOS oil-water separators

They separate oil from condensate. Oil stays in the polypropylene fibre and activated carbon fills, water flows out.

  • residual oil below 10 ppm
  • 4 sizes for compressors up to 35.5 m³/min
  • fills are replaced once a year
View separators

Not sure which filtration grades you need? The calculator in industrial filtration puts them together by application, pressure and flow, including condensate drainage.

Filtration calculator

Omega Air range side by side

Group, series, rating and use
GroupSeriesRatingUse
Industrial filtersAAF, AAFHT, BF, BFHP, HFup to 16, 25 and 50 barcompressed air lines, hot air up to +120 °C
High-pressure filtersCHP, IHP100, 250 and 420 barhigh-pressure lines
Stainless steel process filtersPF, HPF, WFIT, WFIF, WFIW, WHFITup to 14 and 50 barfood, pharmaceuticals, chemicals
Sterile filtersSF, SPFup to 10 and 14 barsterile air, they also retain bacteria
Filters for special applicationsAAFS, PPA, B-AIR, AAFO2, HFO2, P-VAC, M-VACup to 16 and 50 bar, vacuum from 20 mbarpaint shops, breathing air, oxygen, vacuum pumps
Cyclone separatorsAAFC, HFC, CHP, IHP, CS, SFHup to 16, 50 and 420 barliquid water and oil right after the compressor
Refrigeration dryersRDS, RDLup to 16 and 13 bardew point +3 and +5 °C
Desiccant dryersADRY, B-DRY, F-DRY4 to 16 bardew point −40 °C, −25 or −70 °C on request
Membrane dryersMADRYup to 12 bardew point down to −40 °C without electricity
Activated carbon columnsTACM, TAC, TACF, TACHPup to 16 bar, TACHP up to 420 baroil vapours, oil below 0.003 mg/m³
Oil-water separatorsWOS, WOSMcompressors up to 35.5 m³/minoil from condensate below 10 and 20 ppm
Condensate drainsMCD, AOK, TD, AD20up to 420 barmanual, float, timed and electronic

The manufacturer states filter and dryer flows at 7 bar. All sizes and grades are on the page of each group.

How to put compressed air treatment together

1. Define the quality

Choose the ISO 8573-1 purity class for the application: three numbers for solid particles, water and oil. A workshop needs 3:4:4, painting 1:4:1 and food in direct contact 1:2:1.

2. Order the grades

A separator or basic filter goes right after the compressor, followed by the dryer and the finer grades. Always place the 0.1 µm fine pre-filter before the 0.01 µm microfilter and activated carbon only after the microfilter.

3. Choose the size

Select the filter and dryer by compressor flow and line pressure. Flows are given at 7 bar; at lower pressure a filter passes less air.

4. Maintain

Replace elements once a year, sooner if the pressure drop rises. Remove condensate with a drain and replace the WOS separator fills once a year.

Frequently asked questions

What is the difference between a fine pre-filter and a microfilter?
A fine pre-filter captures particles down to 0.1 µm and oil to 0.1 mg/m³, a microfilter down to 0.01 µm and 0.01 mg/m³. The pre-filter always goes before the microfilter to protect its element.
How do I find a replacement element for an Omega Air filter?
The element has the same code as the filter with the letter V at the end: the AAFP-78 filter takes the AAFP-78V element. Most elements are replaced once a year, sooner if the indicator shows a higher pressure drop.
Which Omega Air dryer should I choose?
For workshops and most plants an RDS refrigeration dryer with a +3 °C dew point is enough. Very dry air or lines exposed to frost need an ADRY desiccant dryer with a −40 °C dew point. The MADRY membrane dryer needs no electricity and suits small flows right at the machine.
Where does an activated carbon column go?
After the dryer and a 0.01 µm microfilter, which captures oil droplets and aerosol. The column then removes oil vapours below 0.003 mg/m³. A 1 µm dust filter goes after it to catch dust from the carbon.
What is an oil-water separator for?
Condensate from an oil-lubricated compressor contains oil and must not go into the sewer untreated. The WOS separator captures the oil in its fills and water flows out with less than 10 ppm residual oil. The discharge limit is set by the local sewer regulations.
Which condensate drains does Omega Air make?
Manual MCD drains, float AOK drains that work without electricity, timed TD drains up to 420 bar and the electronic AD20. It senses the level with a capacitive sensor and drains condensate without losing air.

Most Omega Air product pages have a technical data sheet or drawing to download; AAF filters and ADRY and MADRY dryers also come with a manual in Czech. Omega Air is a brand of the Slovenian company OMEGA AIR d.o.o. Ljubljana.