Omega Air industrial compressed air filters up to 50 bar, Page 3
Product sorting
List of products
With a G 2" thread and a flow of 16,667 l/min at 7 bar, the AAFP-1000 basic filter traps solid contaminants and dust particles larger than 3 µm. Working pressure up to 16 bar.
With a G 2" thread and a flow of 25,000 l/min at 7 bar, the AAFP-1500 basic filter traps solid contaminants and dust particles larger than 3 µm. Working pressure up to 16 bar.
Spare element AAFS-1000V for microfilter AAFS-1000. Recommended replacement every 12 months or 4,000 operating hours.
Spare element AAFS-510V for microfilter AAFS-510. Recommended replacement every 12 months or 4,000 operating hours.
Spare element AAFS-780V for microfilter AAFS-780. Recommended replacement every 12 months or 4,000 operating hours.
Spare element AAFM-335V for fine pre-filter AAFM-335. Recommended replacement every 12 months or 4,000 operating hours.
Spare element AAFA-335V for activated carbon filter AAFA-335. Recommended replacement within 6 months at the latest, earlier if the oil content is higher.
Spare element HFS-018V for the HFS-018 microfilter with a G 1" thread. Recommended replacement at least once a year or at a pressure drop of 350 mbar.
With a G 1/4" thread and a flow of 417 l/min at 7 bar, the AAFP-25 basic filter traps solid contaminants and dust particles larger than 3 µm. Working pressure up to 16 bar.
Spare element AAFP-1000V for basic filter AAFP-1000. Recommended replacement every 12 months or 4,000 operating hours.
Spare element AAFP-780V for basic filter AAFP-780. Recommended replacement every 12 months or 4,000 operating hours.
With a G 1/4" thread and a flow of 583 l/min at 7 bar, the AAFA-35 activated carbon filter removes residual oil, oil vapours, hydrocarbons and odours; residual oil is below...
Spare element AAFR-1000V for dust filter AAFR-1000. Recommended replacement every 12 months or 4,000 operating hours.
With a G 3/4" thread and a flow of 2,000 l/min at 7 bar, the AAFP-120 basic filter traps solid contaminants and dust particles larger than 3 µm. Working pressure up to 16 bar.
With a G 3/8" thread and a flow of 500 l/min at 7 bar, the AAFP-30 basic filter traps solid contaminants and dust particles larger than 3 µm. Working pressure up to 16 bar.
Spare element HFR-018V for the HFR-018 dust filter with a G 1" thread. Recommended replacement at least once a year or at a pressure drop of 350 mbar.
Spare element AAFH2-78V for catalytic filter AAFH2-78. Recommended replacement within 6 months at the latest, earlier depending on use.
With a G 1/4" thread and a flow of 417 l/min at 7 bar, the AAFS-25 microfilter traps particles larger than 0.01 µm, water and oil; residual oil is below 0.01 mg/m³. Working...
Spare element AAFH2-120V for catalytic filter AAFH2-120. Recommended replacement within 6 months at the latest, earlier depending on use.
With a G 3" thread and a flow of 36,000 l/min at 7 bar, the AAFM-2160 fine pre-filter traps fine solid particles larger than 0.1 µm, water and oil; residual oil is below 0.1...
With a G 1/4" thread and a flow of 417 l/min at 7 bar, the AAFM-25 fine pre-filter traps fine solid particles larger than 0.1 µm, water and oil; residual oil is below 0.1 mg/m³....
Spare element AAFP-1500V for basic filters AAFP-1500 and AAFP-1680. Recommended replacement every 12 months or 4,000 operating hours.
Spare element AAFP-2760V for basic filter AAFP-2760. Recommended replacement every 12 months or 4,000 operating hours.
Spare element AAFM-510V for fine pre-filter AAFM-510. Recommended replacement every 12 months or 4,000 operating hours.
Spare element AAFA2-78V for adsorption filter AAFA2-78. Recommended replacement within 6 months at the latest, earlier if the oil content is higher.
Spare element AAFR-1500V for dust filters AAFR-1500 and AAFR-1680. Recommended replacement every 12 months or 4,000 operating hours.
Spare element AAFR-2160V for dust filter AAFR-2160. Recommended replacement every 12 months or 4,000 operating hours.
With a G 2 1/2" thread and a flow of 28,000 l/min at 7 bar, the AAFP-1680 basic filter traps solid contaminants and dust particles larger than 3 µm. Working pressure up to 16 bar.
With a G 3" thread and a flow of 46,000 l/min at 7 bar, the AAFP-2760 basic filter traps solid contaminants and dust particles larger than 3 µm. Working pressure up to 16 bar.
With a G 1 1/2" thread and a flow of 8,500 l/min at 7 bar, the AAFP-510 basic filter traps solid contaminants and dust particles larger than 3 µm. Working pressure up to 16 bar.
With a G 3/8" thread and a flow of 500 l/min at 7 bar, the AAFM-30 fine pre-filter traps fine solid particles larger than 0.1 µm, water and oil; residual oil is below 0.1 mg/m³....
Spare element AAFA2-198V for adsorption filter AAFA2-198. Recommended replacement within 6 months at the latest, earlier if the oil content is higher.
Spare element AAFS-1500V for microfilters AAFS-1500 and AAFS-1680. Recommended replacement every 12 months or 4,000 operating hours.
Spare element AAFS-2160V for microfilter AAFS-2160. Recommended replacement every 12 months or 4,000 operating hours.
Spare element AAFS-2760V for microfilter AAFS-2760. Recommended replacement every 12 months or 4,000 operating hours.
With a G 2" thread and a flow of 16,667 l/min at 7 bar, the AAFS-1000 microfilter traps particles larger than 0.01 µm, water and oil; residual oil is below 0.01 mg/m³. Working...
With a G 1" thread and a flow of 5,583 l/min at 7 bar, the AAFS-335 microfilter traps particles larger than 0.01 µm, water and oil; residual oil is below 0.01 mg/m³. Working...