Spare element UF-15 for the F15-B-UF ultra-fine microfilter 0.01 microns · oil below 0.001 mg/m³ · class 1-x-1
Code: UF-15Related products
Product detailed description

Spare element UF-15 for the Hankison NGF F15-B-UF ultra-fine microfilter. You can recognise the stage by the end cap — for UF it is yellow.
The element traps particles larger than 0.01 µm and removes oil down to a residual content below 0.001 mg/m³.
Specifications
| Parameter | Value |
|---|---|
| Stage | Ultra-fine microfilter UF |
| Particle retention | 0.01 µm |
| Residual oil | < 0.001 mg/m³ |
| ISO 8573-1 class | 1-x-1 |
| Particle removal efficiency | 99.999+ % |
| Oil removal efficiency | 99.9+ % |
| Maximum inlet liquid load | 0.1 g/m³ |
| Pressure drop of a new element (dry / wet) | 60 mbar / 140 mbar |
| Element replacement | after 3,000 operating hours, within 12 months at the latest, or at a pressure drop of 400 mbar |
| Element end cap colour | yellow |
| Working pressure | 11 bar |
| Inlet air temperature | +2 to +66 °C |
Which filter it fits
Each NGF filter size has its own element. The number after the hyphen in the element code matches the filter size; this one only fits the filter below.
| Filter | Connection | Flow at 7 bar | Working pressure |
|---|---|---|---|
| F15-B-UF | G 2 1/2" | 33,983 l/min | 11 bar |
How to replace the element
Replace the element after 3,000 operating hours, within 12 months at the latest, or at a pressure drop of 400 mbar.
- Close the air inlet and outlet and depressurise the filter — via the button or bleed screw of the drain, or on a CF filter by opening the ball valve.
- Unscrew the bowl anticlockwise and unscrew the old element. Wipe the inside of the filter head.
- Lubricate the O-ring of the new element and fit it so that the slot in the element engages the projection in the filter head. Do not touch the foam sleeve of HF, UF and CF elements with your fingers.
- Screw the bowl back on, replacing and lubricating its O-ring if necessary, and slowly pressurise the filter.
Where to place it

It goes after the PF dust filter, possibly also after the HF microfilter, and before CF activated carbon.
You will find elements for the other sizes with the filters of the same stage and in the NGF accessories.
Additional parameters
| Category: | Spare elements for Hankison NGF filters |
|---|---|
| Version: | Microfilter |
| Pressure: | 11 bars |
| Certification: | ISO 8573-1 (IUTA) |
| Filtration: | 0.01 µm |
| Filter insert: | For filter F15-B-UF |
| Working temperature: | +2 / +66 °C |
| Flow: | 29,166 l/min |
| Residual oil: | <0.001 mg/m³ |
| Quality class - oils: | 1 |
| Quality class - solid impurities: | 1 |
Product rating
Be the first who will post an article to this item!
Hankison joined forces with SPXThe company Hankison has been operating on the commercial market since 1948 and over the years has always been a pioneer in the field of compressed air treatment. To this day, it continues to expand its capabilities and technology in the manufacture of dryers and filters for compressed air. Currently, Hankison has joined forces with a group of other companies with a similar focus - SPX Flow Technology. Thanks to this step, the company is able to continuously innovate and improve the quality of its product offering. They put their shared experience to good use in state-of-the-art laboratories to ensure that the resulting products are the best that can be found on the world market. Of course there are various quality system certifications (e.g. ISO 9001:2009 and ISO 14001:2009). This combination is also reflected in the final price of the products, which will surely please your wallet. |
![]() |