Refrigeration dryer for compressed air Omega Air RDL-100 for a pressure dew point of +5 °C (water class 5). Flow rate 100 m³/h (1,667 l/min) at 7 bar, working pressure up to 13...
Spare element HFS-007V for the HFS-007 microfilter with a G 1/2" thread. Recommended replacement at least once a year or at a pressure drop of 350 mbar.
Spare element AAFM-198V for fine pre-filter AAFM-198. Recommended replacement every 12 months or 4,000 operating hours.
With a G 1/2" thread and a flow of 1,300 l/min at 7 bar, the AAFA2-78 activated carbon adsorption filter removes residual oil, oil vapours and aerosols to below 0.005 mg/m³....
Spare element AAFP-780V for basic filter AAFP-780. Recommended replacement every 12 months or 4,000 operating hours.
Spare element HFM-007V for the HFM-007 fine pre-filter with a G 1/2" thread. Recommended replacement at least once a year or at a pressure drop of 350 mbar.
Spare cyclone element AAFC-2160V for the AAFC-2160 cyclone separator. Recommended replacement every 12 months or 4,000 operating hours.
Spare cyclone element CHPC-018V for the CHP1C-018, CHP2C-018 and CHP4C-018 cyclone separators. The separator has no filter element — the cyclone element is its separating part.
WALTER WDF-190 refrigeration dryer for compressed air with a built-in 1 µm pre-filter and 0.01 µm fine filter. Pressure dew point +3 °C (water class 4), flow rate 190 m³/h...
With a G 1" thread and a flow of 3,300 l/min at 7 bar, the AAFM-198 fine pre-filter traps fine solid particles larger than 0.1 µm, water and oil; residual oil is below 0.1...
Desiccant dryer ADRY-6 for 6 Nm³/h (100 l/min) of compressed air, G 3/8" connection. Pressure dew point −40 °C, working pressure 4 to 16 bar, inlet microfilter and outlet dust...
With a G 1" thread and a flow of 5,583 l/min at 7 bar, the AAFP-335 basic filter traps solid contaminants and dust particles larger than 3 µm. Working pressure up to 16 bar.
Service kit ADRY-105-1R for maintaining the ADRY-105 desiccant dryer after 1 year of operation. It contains filter elements and silencers.
With a G 3/4" thread and a flow of 2,000 l/min at 7 bar, the AAFA2-120 activated carbon adsorption filter removes residual oil, oil vapours and aerosols to below 0.005 mg/m³....
Sell-off (remaining stock). The RDP-75 dryer is the previous version (14 bar, R134a refrigerant, EMD12 drain). Its successor with the same flow rate is the RDS-75.Condensation...
With a G 1/4" thread and a flow of 417 l/min at 7 bar, the AAFA-25 activated carbon filter removes residual oil, oil vapours, hydrocarbons and odours; residual oil is below...
Spare element AAFMS2-198V for molecular sieve filter AAFMS2-198. Recommended replacement within 6 months at the latest, earlier depending on use.
Spare element AAFMS2-335V for molecular sieve filter AAFMS2-335. Recommended replacement within 6 months at the latest, earlier depending on use.
Spare element AAFMS2-510V for molecular sieve filter AAFMS2-510. Recommended replacement within 6 months at the latest, earlier depending on use.
Spare element AAFMS2-780V for molecular sieve filter AAFMS2-780. Recommended replacement within 6 months at the latest, earlier depending on use.
With a G 3/8" thread and a flow of 500 l/min at 7 bar, the AAFA-30 activated carbon filter removes residual oil, oil vapours, hydrocarbons and odours; residual oil is below...
Spare element AAFA-780V for activated carbon filter AAFA-780. Recommended replacement within 6 months at the latest, earlier if the oil content is higher.
Spare element AAFS-2160V for microfilter AAFS-2160. Recommended replacement every 12 months or 4,000 operating hours.
Desiccant dryer ADRY-36 for 36 Nm³/h (600 l/min) of compressed air, G 3/8" connection. Pressure dew point −40 °C, working pressure 4 to 16 bar, inlet microfilter and outlet dust...
Spare element AAFP-198V for basic filter AAFP-198. Recommended replacement every 12 months or 4,000 operating hours.
Spare element AAFS-198V for microfilter AAFS-198. Recommended replacement every 12 months or 4,000 operating hours.
With a DN150 flange and a flow of 156,667 l/min at 7 bar, the BFA-0900 activated carbon filter removes residual oil, oil vapours, hydrocarbons and odours; residual oil is below...
With a DN200 flange and a flow of 209,167 l/min at 7 bar, the BFA-1200 activated carbon filter removes residual oil, oil vapours, hydrocarbons and odours; residual oil is below...
With a DN200 flange and a flow of 261,667 l/min at 7 bar, the BFA-1500 activated carbon filter removes residual oil, oil vapours, hydrocarbons and odours; residual oil is below...
With a DN250 flange and a flow of 314,167 l/min at 7 bar, the BFA-1800 activated carbon filter removes residual oil, oil vapours, hydrocarbons and odours; residual oil is below...
With a DN250 flange and a flow of 418,333 l/min at 7 bar, the BFA-2500 activated carbon filter removes residual oil, oil vapours, hydrocarbons and odours; residual oil is below...
With a DN300 flange and a flow of 523,333 l/min at 7 bar, the BFA-3000 activated carbon filter removes residual oil, oil vapours, hydrocarbons and odours; residual oil is below...
With a DN150 flange and a flow of 156,667 l/min at 7 bar, the BFP-0900 basic filter traps coarse solid contaminants larger than 3 µm and liquid water. Working pressure up to 16...