Industrial compressed air filters ISO 8573.1
Get rid of mechanical impurities and oil from compressed air efficiently with our extensive filtration programme. Not only will you get better quality compressed air to suit more applications, but you will also extend the life of many compressor system components. If the above matters to you, please feel free to explore our filtration category properly. You will find Omega Air filters, B-Air filters or NGF and Mark filters. We also offer new filter, catalyst and adsorption inserts for all filters. More about the whole program and filtering principles in the sequel.
#ShowMore#
Why is it necessary to filter compressed air?
The compressed air produced by your compressor - whether piston or screw - is not of good quality without post-treatment and is not suitable for many applications. This is because the compressor inlet filter only captures part of the mechanical impurities. However, they are not the only problem that degrades the quality of the produced air.
What does the produced compressed air contain?
- mechanical impurities
- humidity
- oil vapours (if it is an oil compressor)
This harmful triple combination is causing great trouble for any equipment that is connected to the compressor. Pneumatic tools - over time, they lose power and increase consumption, corrode inside, destroy seals, clog holes, become stuck and negatively affect the quality of work. Its lifetime is shortened many times over. Imagine what untreated compressed air can do to the individual components of a large automated line full of valves, cylinders and variously controlled moving parts. Shutting down a line for servicing can cost a company hundreds of thousands.
Compressed air quality
Compressed air quality is described in standardsiSO 8573-1 with seven classes, from 0 to 6. This guideline is crucial for every operator, as it sets out the exact quality requirements for different applications. Each class has a prescribed maximum content of solids, water and oil. We go into detail about this issue in this article, which will give you advice on how to choose water filters to connect behind your compressor: How to filter compressed air
In addition to the filters themselves, you may also be interested in:
- filter inserts for activated carbon filters
- filter inserts for microfilters
- filter inserts for dust filters
- catalytic filter inserts
- adsorption filter inserts
- air filter cartridge contamination indicators
Filters according to the quality class of solid impurities:
- quality class 1
- quality class 2
- quality class 3
- quality class 4
- quality class 5
- quality class 6
- quality class 7
Industrial filters divided according to condensate discharge:
-
Omega air filters; 16 to 64 bar
-
High pressure filters CHP/IHP; carbon and stainless steel up to 400 bar
-
NGF air filtration; including clogging indication
-
Stainless steel process filters; air and gas distribution
-
Sterile stainless steel filters; SFS and SPF filtration
-
Vacuum filters; filtration for vacuum
-
PPA filter system; for painting equipment
-
B-AIR filtration; for breathable air
-
Filters in AFS design; silicone-free filtration
-
Accessories for filters; inserts, indications,...
Product sorting
List of products
Simple mechanical device for checking the condition of the filter cartridge. Contributes to reducing power consumption by alerting to high pressure gradients. If the filter...
Hankison filter cartridge for SF series air filter type F03. The filter insert is suitable for easy replacement by means of a thread in the filter. The maximum pressure of the...
AAFR dust filter in 3/8" design to remove dust impurities up to 1 um from compressed air according to ISO 8573-1 class 3. Body with easily removable container and designed for a...
Designed to accurately display the pressure gradient value of the filter cartridge. Dial with coloured fields - red to indicate both wear and tear of the insert. Optimized...
AAFC cyclone separator in 3/4" design with a flow rate of 2,000 l/min for partial removal of condensate from compressed air. Here the flow changes to rotational and due to the...
AAFP basic filter in 3/4" design for removal of basic mechanical impurities up to 3 um from compressed air according to ISO 8573-1 class 6. Body with easily removable container...
AAFP basic filter in 1 1/2" design for removal of basic mechanical impurities up to 3 um from compressed air according to ISO 8573-1 class 6. Body with easily removable...
Float valve for condensate discharge from compressed air system working on float principle. Version AOK16B for internal mounting of filter vessels using 1/2" thread.
AAFC 2" cyclone separator with a flow rate of 16,667 l/min for partial removal of condensate from compressed air. Here the flow changes to rotational and due to the rotation and...
Hankison filter cartridge for SF series air filter type F08. The filter insert is suitable for easy replacement by means of a thread in the filter. The maximum pressure of the...
Hankison filter cartridge for SF series air filter type F10. The filter insert is suitable for easy replacement by means of a thread in the filter. The maximum pressure of the...
Float-operated condensate drain valve for compressed air systems up to 13 bar. Version AOK13PA for external mounting on the filter body with 1/2" thread.
Hankison filter cartridge for HF series air filter type F11. The filter insert is suitable for easy replacement by means of a thread in the filter. The maximum pressure of the...
Replacement cyclone cartridge for liquid water filtration AAFC-78V. Recommended replacement 12 months or every 4,000 MH and upon indication of clogging of the filter element by...
Hankison adsorption filter cartridge for CF series air microfilter type F06. The filter insert is suitable for easy replacement by means of a thread in the filter. The maximum...
Replacement cyclone cartridge for liquid water filtration AAFC-60V. Recommended replacement 12 months or every 4,000 MH and upon indication of clogging of the filter element by...
Replacement cyclone insert for liquid water filtration AAFC-120V. Recommended replacement 12 months or every 4,000 MH and upon indication of clogging of the filter element by...
Replacement cyclone cartridge for liquid water filtration AAFC-198V. Recommended replacement 12 months or every 4,000 MH and upon indication of clogging of the filter element by...
Replacement fine filter cartridge with 0.1 µm filtration capacity for OMEGA AIR AAFM-25 and AAFM-30 pre-filters. Recommended replacement 12 months or every 4,000 MH and when...
Hankison 's NGF series SF type basic ISO filter for compressed air. Filter size F03 with 3/8" female threads. The filter is equipped with a clogging indicator and an automatic...
AAFS 1/4" microfilter for removal of micro impurities up to 0.01 um from compressed air according to ISO 8573-1 class 1. Body with easily removable container and designed for a...
Replacement microfiltration cartridge with filtration capacity 0,01 µm for OMEGA AIR AAFS-780 microfilters. Recommended replacement 12 months or every 4,000 MH and when clogging...
Replacement dust filter cartridge with 1 µm filtration capacity for OMEGA AIR AAFR-25 and AAFR-30 filters. Recommended replacement 12 months or every 4,000 MH and when clogging...
AAFS 1/2" microfilter to remove micro impurities up to 0.01 um from compressed air according to ISO 8573-1 class 1. Body with easily removable container and designed for a flow...
Replacement microfiltration cartridge with filtration capacity of 0.01 µm for OMEGA AIR AAFS-335 microfilters. Recommended replacement 12 months or every 4,000 MH and when...
Replacement microfiltration cartridge with filtration capacity 0,01 µm for OMEGA AIR AAFS-510 microfilters. Recommended replacement 12 months or every 4,000 MH and when clogging...
AAFC cyclone separator in 1" design with a flow rate of 3,300 l/min for partial removal of condensate from compressed air. Here the flow changes to rotational and due to the...
AAFS 1" microfilter to remove micro impurities up to 0.01 um from compressed air according to ISO 8573-1 class 1. Body with easily removable container and designed for a flow...
AAFS microfilter in 3" design to remove micro impurities up to 0.01 um from compressed air according to ISO 8573-1 class 1. Body with easily removable container and designed for...
Microfilter AAFS in 1/2" design to remove micro impurities down to 0.01 um from compressed air according to ISO 8573-1 class 1. Body with easily removable bowl and designed for...
AAFC cyclone separator in 3/8" design with a flow rate of 1,000 l/min for partial removal of condensate from compressed air. Here the flow changes to rotational and due to the...
AAFS 1" microfilter to remove micro impurities up to 0.01 um from compressed air according to ISO 8573-1 class 1. Body with easily removable container and designed for a flow...
Replacement microfiltration cartridge with filtration capacity of 0.01 µm for OMEGA AIR AAFS-2160 microfilters. Recommended replacement 12 months or every 4,000 MH and when...
Replacement microfilter cartridge with filtration capacity of 0.01 µm for OMEGA AIR AAFS-1500 and AAFS-1680 microfilters. Recommended replacement 12 months or every 4,000 MH and...
Replacement microfilter cartridge with filtration capacity of 0.01 µm for OMEGA AIR AAFS-1000 microfilters. Recommended replacement 12 months or every 4,000 MH and when clogging...
Electronic condensate drain from a compressed air system up to 16 bar, operating on a timed valve switching. External mounting on the filter body using a 1/2" thread. Simple...
AAFM pre-filter in 3/8" design for removal of fine impurities up to 0.1 um from compressed air according to ISO 8573-1 class 2. Body with easily removable container and designed...
Replacement cyclone cartridge for liquid water filtration AAFC-510V. Recommended replacement 12 months or every 4,000 MH and upon indication of clogging of the filter element by...
Replacement cyclone insert for liquid water filtration AAFC-1000V. Recommended replacement 12 months or every 4,000 MH and upon indication of clogging of the filter element by...
AAFB coarse filter in 3/8" design to remove the largest mechanical impurities up to 15 um from compressed air according to ISO 8573-1 class 7. Body with easily removable...