SPINN LARGE compressors 15-22 kW
Six models, 15 to 22 kWThe SPINN Large range is the pinnacle of the ABAC lineup that we carry. Six machines with power inputs of 15; 18.5 and 22 kW and flow rates from 2,215 to 3,090 litres per minute — a size at which the question is no longer which compressor to buy, but how to design the entire compressor room.
That's exactly why the range is split into two halves. Three standalone machines for facilities that already have an air receiver and drying. And three complete stations on a five-hundred-litre tank with a refrigerant dryer, where everything arrives at once on a single frame.
What sets the range apart
S67 block on V-belts
The newest and largest screw block we carry; in continuous duty its efficiency is what decides the electricity bill. The motor drives it through V-belts — parts that are re-tensioned and eventually replaced.
Vertical three-stage oil separation
Highly efficient and built upright. Oil is separated in three steps, so the air reaching the pipework is practically free of oil mist.
Oil sight glass on the outside
Check the oil level by eye, with no panel to remove and no tools. A small thing you appreciate on the daily walk-round.
Infologic2 controller
Monochrome display, operating settings, signalling and tracking of the 2,000 – 4,000 – 8,000 running-hour service intervals.
D versions: a turnkey station
A refrigerant dryer with a dew-point indicator and R410A refrigerant, a 500 l receiver and a ball valve for draining condensate. All on one frame.
What's inside
Under the canopy sits the S67 screw block, driven from the electric motor by V-belts. Air leaving the block goes into vertical three-stage oil separation — in the cutaway photographs that is the tall black vessel in the middle of the machine.
The standalone models have an enclosure of 1,130 × 780 × 1,250 mm, the same for both the 15 kW and 22 kW versions. The tank-mounted version measures 1,904 × 780 × 1,833 mm. The tank with dryer always adds exactly 275 kg and 774 mm in length.
What the machines look like



Which model to choose
| ABAC SPINN Large screw compressors (10 bar / 400 V) | ||||||
|---|---|---|---|---|---|---|
| Model | Flow rate | Power input | Air tank | Dryer | Noise level | Weight |
| SPL-15/10 | 2,215 l/min | 15 kW | — | no | 67 dB(A) | 313 kg |
| SPL-18/10 | 2,590 l/min | 18.5 kW | — | no | 69 dB(A) | 328 kg |
| SPL-22/10 | 3,090 l/min | 22 kW | — | no | 70 dB(A) | 344 kg |
| SPL-15/10D-500 | 2,215 l/min | 15 kW | 500 l | yes | 67 dB(A) | 588 kg |
| SPL-18/10D-500 | 2,590 l/min | 18.5 kW | 500 l | yes | 69 dB(A) | 603 kg |
| SPL-22/10D-500 | 3,090 l/min | 22 kW | 500 l | yes | 70 dB(A) | 619 kg |
All models: 10 bar, 400/50 V/Hz, three-phase, outlet G 1", S67 block on V-belts, service intervals 2,000 – 4,000 – 8,000 motor hours. Standalone units 1,130 × 780 × 1,250 mm, D-500 version 1,904 × 780 × 1,833 mm. Output according to ISO 1217 Annex C, noise level according to ISO 2151:2004.
#showmore#
Where the range is used
Production halls
Compressed air as the backbone medium for the line and for air tools, drawn throughout the shift.
Paint shops with several booths
Steady pressure and dry air from the refrigerant dryer, with no droplets in the spray.
Metalwork and fabrication
Continuous draw for grinders, impact wrenches and clamping. The enclosed canopy keeps workshop noise bearable.
Sites building a compressor room from scratch
The D-500 version arrives as a single unit — compressor, receiver and dryer on a shared frame.
Warranty
The standard warranty is two years. ABAC offers an extension to five years for an extra charge of 5% of the machine price (code ABA-5R) — with us, you get this surcharge as a free gift with the product. For D-500 versions, there is additionally a ten-year warranty against rust-through of the five-hundred-litre air receiver.
Ventilek’s advice
From fifteen kilowatts and up, the machine's price stops being the deciding factor, and consumption takes over. A twenty-two-kilowatt compressor running three shifts will use up more in electricity over a year than it cost to buy. That's why, at this size, it pays to sit down with the actual consumption figures before looking at the price list.
Frequently asked questions
- How does a screw compressor actually work?
- Two intermeshing rotors turn against each other, and the air caught between them is compressed progressively in a space that narrows towards the outlet. Unlike a piston machine there are no strokes, only continuous flow — which is why a screw compressor can run without stopping and why it is quieter. Oil in the rotor chamber lubricates, cools and seals the clearances; before the air leaves for the pipework the oil is removed in vertical three-stage separation.
- When to take a standalone machine and when the D-500?
- Standalone, when you already have a receiver and drying on site and are only replacing the compressor. The D-500, when you are building the compressor room from scratch, or when sourcing a compressor, a receiver and a dryer from different suppliers would mean a project of its own. Why air is dried at all is covered in Why and how to dry compressed air.
- How much space does the machine need?
- The standalone models have a 1,130 × 780 mm footprint and stand 1,250 mm tall, identically across all three. The versions on a receiver measure 1,904 × 780 × 1,833 mm. On top of that allow room around the machine for servicing and, above all, an air inlet and outlet for cooling.
- Why does the compressor room have to be ventilated?
- Because practically all the electricity that enters a compressor comes out of it as heat. For a twenty-two-kilowatt machine, that's twenty-two kilowatts of heat that needs somewhere to go. Without ventilation, the machine draws in its own heated air, loses output, and eventually shuts down on temperature.
- How does it differ from the SPINN Maxi range?
- SPINN Maxi tops out at fifteen kilowatts, Large starts there and goes up to twenty-two. Large has a larger S67 screw block and vertical three-stage oil separation; tank-mounted versions use a five-hundred-litre air tank instead of the smaller one.
- What about the warranty?
- The standard warranty is two years. ABAC offers an extension to five years for an extra charge of 5% of the machine price (code ABA-5R) — with us, you get this surcharge as a free gift with the product. For D-500 versions, there is additionally a ten-year warranty against rust-through of the five-hundred-litre air receiver.
- How often is it serviced?
- The Infologic2 unit tracks the 2,000 – 4,000 – 8,000 running-hour steps and reports when the time comes. Besides filters and oil, this range has V-belts that are re-tensioned and eventually replaced.
Bestsellers
Product sorting
List of products
A standalone 18.5 kW screw compressor delivering 2,590 l/min at 10 bar. It adds 375 litres per minute over the 15 kW and gives up 500 against the 22 kW — sitting exactly between...
A standalone 15 kW screw compressor delivering 2,215 l/min at 10 bar. Of the three it makes the most air per kilowatt. The quietest (67 dB) and the lightest (313 kg), though its...
A complete compressed-air station: a 15 kW compressor delivering 2,215 l/min, a 500-litre receiver and a refrigerant dryer on one frame. Connect power and pipework — nothing is...
A complete compressed-air station: an 18.5 kW compressor delivering 2,590 l/min, a 500-litre receiver and a refrigerant dryer on one frame. The middle of the three complete...
A standalone 22 kW screw compressor delivering 3,090 l/min at 10 bar. The strongest machine in the range, on a 1,130 × 780 mm footprint — the same as the 15 kW.
The largest complete compressed-air station in the range: a 22 kW compressor delivering 3,090 l/min, a 500-litre receiver and a refrigerant dryer on one frame. The most powerful...