SPFIW20 welded stainless steel pre-filters up to 14 bar

The SPFIW20 welded pre-filter has an element made of sintered stainless steel 1.4404 in a welded design and traps solid particles larger than 20 µm. It withstands up to +150 °C.
The SPFIW20 filter comes in 12 sizes (G 1/4" to 3") with flows of 1,250 to 60,000 l/min at 7 bar; working pressure up to 14 bar. It is one of the twelve stages of the SPF filters — the housing is the same for all stages, only the element differs.
SPFIW20 filters by size
The size determines the connection and the flow. Each size has its own PF range spare element.
| SPFIW20 filters and spare elements by size | ||||||
|---|---|---|---|---|---|---|
| Filter | Connection | l/min at 7 bar | Nm³/h at 7 bar | Height A × diameter C | Weight | Spare element |
| SPFIW20-005 | G 1/4" | 1,250 | 75 | 225 × 76.1 mm | 1.9 kg | PFIW20-005V |
| SPFIW20-007 | G 3/8" | 1,750 | 105 | 251 × 76.1 mm | 2 kg | PFIW20-007V |
| SPFIW20-010 | G 1/2" | 2,500 | 150 | 258 × 76.1 mm | 2.1 kg | PFIW20-010V |
| SPFIW20-018 | G 3/4" | 3,750 | 225 | 282 × 76.1 mm | 2.3 kg | PFIW20-018V |
| SPFIW20-030 | G 1" | 5,250 | 315 | 299 × 88.9 mm | 3.1 kg | PFIW20-030V |
| SPFIW20-047 | G 1 1/4" | 7,000 | 420 | 359 × 88.9 mm | 3.4 kg | PFIW20-047V |
| SPFIW20-070 | G 1 1/2" | 10,000 | 600 | 395 × 114.3 mm | 4.7 kg | PFIW20-070V |
| SPFIW20-094 | G 2" | 15,000 | 900 | 464 × 114.3 mm | 5.3 kg | PFIW20-094V |
| SPFIW20-150 | G 2" | 21,000 | 1,260 | 592 × 114.3 mm | 6 kg | PFIW20-150V |
| SPFIW20-175 | G 2 1/2" | 28,000 | 1,680 | 743 × 139.7 mm | 11.4 kg | PFIW20-175V |
| SPFIW20-200 | G 3" | 40,000 | 2,400 | 995 × 139.7 mm | 12 kg | PFIW20-200V |
| SPFIW20-240 | G 3" | 60,000 | 3,600 | 1,029 × 168.3 mm | 18 kg | PFIW20-240V |
The flows apply to a pressure of 7 bar and a temperature of +20 °C. Dimensions and weights according to the manufacturer; you will find further data on the product page of each filter.
#showmore#
When to use it
The welded pre-filter IW20 is the second design of the 20 µm stage alongside the sintered pre-filter I20 and goes in the same place in the filtration. It does not trap oil; the manufacturer does not state an ISO 8573-1 class for it.
The element is made entirely of stainless steel and, like the housing, withstands up to +150 °C.
Where to place it

At the start of the filtration or after the SPFN25 coarse filter, before the SPFN5 basic filter or the SPFM fine pre-filter — instead of the SPFI20 sintered pre-filter.
Flow by pressure
The catalogue flows apply to a pressure of 7 bar and a temperature of +20 °C. At a different pressure, they are multiplied by the correction factor: 1.88 at 14 bar.
| SPFIW20 filter flow in l/min by pressure | ||||
|---|---|---|---|---|
| Size (connection) | 4 bar | 7 bar | 10 bar | 14 bar |
| 005 (G 1/4") | 788 | 1,250 | 1,725 | 2,350 |
| 007 (G 3/8") | 1,103 | 1,750 | 2,415 | 3,290 |
| 010 (G 1/2") | 1,575 | 2,500 | 3,450 | 4,700 |
| 018 (G 3/4") | 2,363 | 3,750 | 5,175 | 7,050 |
| 030 (G 1") | 3,308 | 5,250 | 7,245 | 9,870 |
| 047 (G 1 1/4") | 4,410 | 7,000 | 9,660 | 13,160 |
| 070 (G 1 1/2") | 6,300 | 10,000 | 13,800 | 18,800 |
| 094 (G 2") | 9,450 | 15,000 | 20,700 | 28,200 |
| 150 (G 2") | 13,230 | 21,000 | 28,980 | 39,480 |
| 175 (G 2 1/2") | 17,640 | 28,000 | 38,640 | 52,640 |
| 200 (G 3") | 25,200 | 40,000 | 55,200 | 75,200 |
| 240 (G 3") | 37,800 | 60,000 | 82,800 | 112,800 |
Element and maintenance

A PF range element is fitted in the housing — for example, the PFIW20-010V for the SPFIW20-010. The same element also fits the PF, HPF, WFIT, WFIF, WFIW and WHFIT process filters of the same size. The working temperature of the element is +1.5 to +150 °C.
The filter is supplied with an element, without a condensate drain. You will find all elements among the PF range spare elements.
Replace the element at least once every 12 months. Once a year, also check the housing for visible damage.
The same stage in other ranges
Stage IW20 also comes in process filters: PFIW20 up to 14 bar, HPFIW20 up to 50 bar, WFITIW20 up to 14 bar, WFIFIW20 up to 14 bar, WFIWIW20 up to 14 bar and WHFITIW20 up to 50 bar. The elements are the same for all ranges.
Ventilek’s tip
Two designs of the 20 µm stage. The sintered pre-filter I20 and the welded IW20 have the same filtration rating and temperature up to +150 °C and go in the same place in the filtration.
- What filtration rating does the SPFIW20 pre-filter have?
- The element traps particles larger than 20 µm. The manufacturer does not state an ISO 8573-1 class for it.
- How does it differ from the SPFI20?
- Both elements are made of sintered stainless steel 1.4404 with a filtration rating of 20 µm; the IW20 element is of a welded design.
- When should the element be replaced?
- At least once every 12 months.
Bestsellers
Product sorting
List of products
With a G 1/4" connection and a flow of 1,250 l/min at 7 bar, the SPFIW20-005 welded pre-filter traps solid contaminants larger than 20 µm and protects the finer stages after it....
With a G 3/8" connection and a flow of 1,750 l/min at 7 bar, the SPFIW20-007 welded pre-filter traps solid contaminants larger than 20 µm and protects the finer stages after it....
With a G 1/2" connection and a flow of 2,500 l/min at 7 bar, the SPFIW20-010 welded pre-filter traps solid contaminants larger than 20 µm and protects the finer stages after it....
With a G 3/4" connection and a flow of 3,750 l/min at 7 bar, the SPFIW20-018 welded pre-filter traps solid contaminants larger than 20 µm and protects the finer stages after it....
With a G 1" connection and a flow of 5,250 l/min at 7 bar, the SPFIW20-030 welded pre-filter traps solid contaminants larger than 20 µm and protects the finer stages after it....
With a G 1 1/4" connection and a flow of 7,000 l/min at 7 bar, the SPFIW20-047 welded pre-filter traps solid contaminants larger than 20 µm and protects the finer stages after...
With a G 1 1/2" connection and a flow of 10,000 l/min at 7 bar, the SPFIW20-070 welded pre-filter traps solid contaminants larger than 20 µm and protects the finer stages after...
With a G 2" connection and a flow of 15,000 l/min at 7 bar, the SPFIW20-094 welded pre-filter traps solid contaminants larger than 20 µm and protects the finer stages after it....
With a G 2" connection and a flow of 21,000 l/min at 7 bar, the SPFIW20-150 welded pre-filter traps solid contaminants larger than 20 µm and protects the finer stages after it....
With a G 2 1/2" connection and a flow of 28,000 l/min at 7 bar, the SPFIW20-175 welded pre-filter traps solid contaminants larger than 20 µm and protects the finer stages after...
With a G 3" connection and a flow of 40,000 l/min at 7 bar, the SPFIW20-200 welded pre-filter traps solid contaminants larger than 20 µm and protects the finer stages after it....
With a G 3" connection and a flow of 60,000 l/min at 7 bar, the SPFIW20-240 welded pre-filter traps solid contaminants larger than 20 µm and protects the finer stages after it....