High-pressure activated carbon column TACHP-100-50 – 100 bar, 50 Nm³/h

Code: TACHP-100-50
New
Not rated Rating details
€5 628,07 / pcs €4 651,30 excl. VAT Measure price:
up to 14 days
Delivery to:
30.11.2026
Delivery options

High-pressure activated carbon column TACHP-100-50 for a working pressure of 100 bar and a flow of 50 Nm³/h. Removes oil vapours below 0.003 mg/m³, connection G 3/8.

Detailed information

Free shipping
Free shipping
For purchases over 5,000 CZK
We guarantee
We guarantee
Extended warranty and service
Discount voucher
Discount voucher
For every purchase
Return of goods within 14 days
Return of goods within 14 days
Completely at our expense

Product detailed description

The Omega Air high-pressure activated carbon column TACHP-100-50 traps oil vapours from compressed air at pressures up to 100 bar. The nominal flow is 50 Nm³/h and less than 0.003 mg/m³ of oil remains at the outlet.

It belongs to the range of TACHP high-pressure activated carbon columns.

Technical data

ParameterValue
Pressure class100 bar
Nominal flow50 Nm³/h at 100 bar and +20 °C
ConnectionG 3/8
Working temperature+1.5 to +45 °C
Residual oil vapour contentless than 0.003 mg/m³
Dimensions A × B × C1,250 × 340 × 580 mm
Weight50 kg
Service kitTACHP-100-50S

Flow under other conditions

At lower pressure the column handles less: for example, at 80 bar 40 Nm³/h (50 × 0.80).

Pressure factor – class 100 bar

Pressure bar5060708090100
Factor0.500.600.700.800.901.00

Air temperature factor

Temperature °C202530354045
Factor1.000.980.970.920.860.75

Service kit and carbon charge

Activated carbon is replaced every 12 months or earlier, the service kit TACHP-100-50S is used for the replacement. Check the oil content once a month.

Installation and maintenance

A coalescing microfilter is recommended upstream of the TACHP column and a 1 µm dust filter is required downstream. The oil content is checked once a month, the activated carbon is replaced every 12 months or earlier. The column also serves as a safeguard against oil carry-over if filtration fails.

Additional parameters

Category: Compressed air dryers for compressors
Pressure: 100 bar
Connecting: 3/8"
Dimensions: 580 × 340 × 1,250 mm
Flow: 833 l/min
Service interval: monthly oil content check
ISO class: 0/1 - ISO 8573.1
Product type: Complete filter
Equipment: Activated carbon
Residual oil: 0.003 mg/m³
Dryer type: Activated carbon
Filtration stage: Activated carbon

Product rating

Be the first who will post an article to this item!

Do not fill out this field

How would you rate this product? Choose 1 to 5 stars, where 1 is the worst and 5 is the best rating.

Security check

By submitting your review you agree to the privacy policy

Omega Air is a Slovenian manufacturer of compressed air treatment equipment based in Ljubljana. Founded in 1988, the company now has 370 employees and exports to more than 80 countries. It has its own development team and patents and carries out almost all production in its own facilities.

We mainly offer industrial filters up to 420 bar with replacement elements, stainless steel process and sterile filters, refrigeration, desiccant and membrane dryers, activated carbon columns, oil-water separators and condensate drains. They are used in workshops and large plants, in food, pharmaceuticals, chemicals and paint shops.

Omega Air AAF filter, IHP and WFIT stainless steel filters with elements, ADRY desiccant dryer and RDS refrigeration dryerSlovenian manufacturer
1988year the Slovenian company was founded
80+countries Omega Air exports to
420 barhighest pressure of CHP and IHP filters
0.01 µmmicrofilter and sterile element

Omega Air filters, dryers and separators

Omega Air AAF compressed air filter

Industrial filters up to 50 bar

Filters for standard air lines. AAF and BF ranges up to 16 bar, BFHP up to 25 bar and HF up to 50 bar. The element sets the filtration grade.

  • from coarse filter to activated carbon
  • G 1/8" to 3" thread or DN80 to DN300 flanges
  • AAFHT for hot air up to +120 °C
View filters
Omega Air IHP stainless steel high-pressure filter with element

CHP and IHP high-pressure filters

For 100, 250 and 420 bar. CHP housings are nickel-plated carbon steel, IHP housings stainless steel.

  • 8 sizes with G 1/4" to 2" thread
  • flow 667 to 11,917 l/min at 7 bar
  • six grades up to activated carbon
View filters
Omega Air HPF stainless steel process filter with element

Stainless steel process filters

1.4404 stainless steel for food and pharma. Six ranges up to 14 and 50 bar with thread, flanges or welding ends.

  • 12 filtration grades in each range
  • sterile element in the PF and HPF ranges
  • flow 1,250 to 352,000 l/min at 7 bar
View filters
Omega Air refrigeration dryer for compressed air

RDS refrigeration dryers

Dew point +3 °C for most plants. The air cools down in the dryer, water condenses and the drain removes it without losing air.

  • 18 sizes, 333 to 31,667 l/min
  • working pressure up to 16 bar
  • controller shows the dew point
View dryers
Omega Air ADRY desiccant dryer with inlet and outlet filter

ADRY desiccant dryers

Very dry air, dew point −40 °C. Moisture is captured by desiccant in two alternating columns.

  • 9 sizes, 6 to 200 Nm³/h
  • dew point −25 or −70 °C on request
  • inlet and outlet filter included
View dryers
Omega Air MADRY membrane dryer with filters

MADRY membrane dryers

They dry without electricity. Water vapour passes through the wall of hollow fibres, dry air stays inside.

  • 12 sizes, 50 to 3,000 l/min
  • dew point down to −40 °C, up to 12 bar
  • fine pre-filter and microfilter included
View dryers
Omega Air TAC activated carbon column

TAC activated carbon columns

They capture oil vapours that filters let through. The air flows through a bed of granular activated carbon.

  • outlet oil below 0.003 mg/m³
  • 19 sizes, 6 to 1,200 Nm³/h
  • up to 16 bar, high-pressure TACHP up to 420 bar
View columns
Omega Air WOS oil-water separators in four sizes

WOS oil-water separators

They separate oil from condensate. Oil stays in the polypropylene fibre and activated carbon fills, water flows out.

  • residual oil below 10 ppm
  • 4 sizes for compressors up to 35.5 m³/min
  • fills are replaced once a year
View separators

Not sure which filtration grades you need? The calculator in industrial filtration puts them together by application, pressure and flow, including condensate drainage.

Filtration calculator

Omega Air range side by side

Group, series, rating and use
GroupSeriesRatingUse
Industrial filtersAAF, AAFHT, BF, BFHP, HFup to 16, 25 and 50 barcompressed air lines, hot air up to +120 °C
High-pressure filtersCHP, IHP100, 250 and 420 barhigh-pressure lines
Stainless steel process filtersPF, HPF, WFIT, WFIF, WFIW, WHFITup to 14 and 50 barfood, pharmaceuticals, chemicals
Sterile filtersSF, SPFup to 10 and 14 barsterile air, they also retain bacteria
Filters for special applicationsAAFS, PPA, B-AIR, AAFO2, HFO2, P-VAC, M-VACup to 16 and 50 bar, vacuum from 20 mbarpaint shops, breathing air, oxygen, vacuum pumps
Cyclone separatorsAAFC, HFC, CHP, IHP, CS, SFHup to 16, 50 and 420 barliquid water and oil right after the compressor
Refrigeration dryersRDS, RDLup to 16 and 13 bardew point +3 and +5 °C
Desiccant dryersADRY, B-DRY, F-DRY4 to 16 bardew point −40 °C, −25 or −70 °C on request
Membrane dryersMADRYup to 12 bardew point down to −40 °C without electricity
Activated carbon columnsTACM, TAC, TACF, TACHPup to 16 bar, TACHP up to 420 baroil vapours, oil below 0.003 mg/m³
Oil-water separatorsWOS, WOSMcompressors up to 35.5 m³/minoil from condensate below 10 and 20 ppm
Condensate drainsMCD, AOK, TD, AD20up to 420 barmanual, float, timed and electronic

The manufacturer states filter and dryer flows at 7 bar. All sizes and grades are on the page of each group.

How to put compressed air treatment together

1. Define the quality

Choose the ISO 8573-1 purity class for the application: three numbers for solid particles, water and oil. A workshop needs 3:4:4, painting 1:4:1 and food in direct contact 1:2:1.

2. Order the grades

A separator or basic filter goes right after the compressor, followed by the dryer and the finer grades. Always place the 0.1 µm fine pre-filter before the 0.01 µm microfilter and activated carbon only after the microfilter.

3. Choose the size

Select the filter and dryer by compressor flow and line pressure. Flows are given at 7 bar; at lower pressure a filter passes less air.

4. Maintain

Replace elements once a year, sooner if the pressure drop rises. Remove condensate with a drain and replace the WOS separator fills once a year.

Frequently asked questions

What is the difference between a fine pre-filter and a microfilter?
A fine pre-filter captures particles down to 0.1 µm and oil to 0.1 mg/m³, a microfilter down to 0.01 µm and 0.01 mg/m³. The pre-filter always goes before the microfilter to protect its element.
How do I find a replacement element for an Omega Air filter?
The element has the same code as the filter with the letter V at the end: the AAFP-78 filter takes the AAFP-78V element. Most elements are replaced once a year, sooner if the indicator shows a higher pressure drop.
Which Omega Air dryer should I choose?
For workshops and most plants an RDS refrigeration dryer with a +3 °C dew point is enough. Very dry air or lines exposed to frost need an ADRY desiccant dryer with a −40 °C dew point. The MADRY membrane dryer needs no electricity and suits small flows right at the machine.
Where does an activated carbon column go?
After the dryer and a 0.01 µm microfilter, which captures oil droplets and aerosol. The column then removes oil vapours below 0.003 mg/m³. A 1 µm dust filter goes after it to catch dust from the carbon.
What is an oil-water separator for?
Condensate from an oil-lubricated compressor contains oil and must not go into the sewer untreated. The WOS separator captures the oil in its fills and water flows out with less than 10 ppm residual oil. The discharge limit is set by the local sewer regulations.
Which condensate drains does Omega Air make?
Manual MCD drains, float AOK drains that work without electricity, timed TD drains up to 420 bar and the electronic AD20. It senses the level with a capacitive sensor and drains condensate without losing air.

Most Omega Air product pages have a technical data sheet or drawing to download; AAF filters and ADRY and MADRY dryers also come with a manual in Czech. Omega Air is a brand of the Slovenian company OMEGA AIR d.o.o. Ljubljana.

Manufacturing company : OMEGA AIR d.o.o. Ljubljana
Address : Cesta Dolomitskega odreda 10, 1000 Ljubljana, Slovenia
E-mail : info@omega-air.si