Remote Compressor Monitoring: Deployment Plan for Technicians

The technician is currently mounting a pressure sensor on the compressor piping.

Remote compressor monitoring ensures continuous measurement of pressure, flow, temperature and vibration, and sends warnings before a failure occurs. Industry estimates suggest that typical operation loses up to approximately one-fifth of compressed air due to leaks. Systems built on protocols such as OPC UA or Modbus detect this loss within days, not months. Kompresory-vzduchotechnika.cz offers local support in designing and installing such a solution.

The main benefits can be summarized in three points:

  • lower energy consumption thanks to early detection of leaks and overloads,
  • fewer emergency repairs, because deviations are addressed before they develop into a failure,
  • maintenance planned according to the actual condition of the machine, not according to a calendar.

Professional tip: Before you start selecting sensors, measure the compressor's current weekly energy consumption. Without a baseline value, you won't know whether monitoring actually saved anything.

Key findings

Remote monitoring only works when it combines the right metrics, reliable connectivity and a clearly defined pilot step before full deployment.

Point Details
Main benefit Combining pressure, flow and vibration reveals a leak or failure before it causes a shutdown.
Leak losses Expert estimates indicate a loss of up to 20% of compressed air due to unaddressed leaks.
Protocol selection Modbus TCP and OPC UA are suitable for wired networks, NB‑IoT and LoRaWAN for remote locations.
Pilot before scaling Verification on 1 to 3 machines over a period of 4 to 6 weeks will show the real return on investment.
Supplier selection Kompresory-vzduchotechnika.cz offers audit, installation, integration, and continuous service as a single package.

Contents

What exactly remote compressor monitoring means

Remote compressor monitoring is a system that measures the machine's operating parameters using sensors, transmits the data via a gateway to a cloud-based or local platform, and evaluates it against set limits. A control unit such as the Elektronikon Nano can monitor pressure, temperature, and operating modes in real time and make them accessible via an application such as SMARTLINK, from anywhere the technician has internet access.

The system works in two modes:

  • active monitoring – the technician reviews the data themselves and looks for deviations,
  • passive monitoring – the system automatically sends an alert only when a value exceeds the threshold.

Deployment is divided into a cloud solution, where data travels to a remote server, and a local network (LAN), which integrates data directly into SCADA via Modbus TCP, OPC UA, or Profinet. The choice depends on whether the company prefers remote access from multiple locations, or a closed network with full control over the data.

Which variables to monitor and what thresholds to set

Monitoring a single variable on its own does not reveal much. The real diagnostic value comes from combining pressure, flow, and vibration, as this shows whether the problem stems from a leak, bearing wear, or compressor overload.

The technician is performing vibration measurement on the compressor bearing.

Variable Why monitor it Sensor type Example threshold value
Pressure Reveals leaks and undersized piping Piezoelectric pressure sensor A drop of more than 0.5 bar compared to the operating pressure
Flow rate Shows actual air consumption vs. machine output Flow meter (thermal or vortex) Deviation above planned consumption
Temperature Signals overheating of the oil or motor Thermocouple / resistance sensor Above the operating temperature for oil-lubricated compressors
Vibration Reveals bearing wear and imbalance Accelerometer Above the vibration value typical for the given machine
Motor current Indicates mechanical overload Current transformer Deviation above the rated value
Operating hours Service interval planning Counter in the control unit Approaching manufacturer's service interval
Air leaks Direct energy loss Acoustic leak detector Estimated loss of over 5% of total output

The estimate that leaks account for a loss of up to approximately one-fifth of compressed air applies to the entire range of industrial piping systems, not just the compressor itself. A persistent deviation lasting longer than one shift is no longer noise, but a signal for intervention. More on how to evaluate vibrations in practice is described in the guide to monitoring compressor vibrations.

Professional tip: Combine pressure, flow, and vibration in a single graph. A pressure drop without a flow drop usually indicates a leak, while a drop in both accompanied by increasing vibration indicates a mechanical fault.

What components make up a monitoring system

The system consists of four layers, and if one is missing, the entire solution loses its purpose.

  • Sensors – measure pressure, temperature, vibration, and current directly on the machine; when selecting them, IP65 or higher protection rating, accuracy, and vibration resistance are decisive factors.
  • Gateway – aggregates data from sensors and converts it from industrial protocols into a format readable by the cloud or SCADA.
  • Cloud or software platform – stores history, generates overviews, and triggers alarms; a system such as SMARTLINK can log data at intervals of just a few minutes, giving the technician a fast reaction time.
  • Notification module – sends alerts by e-mail, SMS, or to an app as soon as a value exceeds the set threshold.

Above these four layers sits a central control unit, the so-called optimizer, which distributes the load among multiple compressors according to current demand.

Evenly distributing operating hours among the machines extends the lifespan of the entire compressor fleet and at the same time reduces energy consumption, as the system shuts down machines that are not needed at a given moment.

The principle of central control and its practical benefits are discussed in the article on parallel compressor control.

Which protocol and connection to choose for your operation

The choice of connectivity determines the reliability of the entire system, not just the data transfer speed.

  • Modbus TCP – a standard for integration into an existing SCADA system, low latency, but limited security without additional encryption.
  • OPC UA – a modern replacement for Modbus with a built-in security layer, suitable for larger operations with multiple systems.
  • MQTT – a lightweight protocol ideal for cloud transfers from remote locations with limited bandwidth.
  • NB-IoT and LoRaWAN – wireless technologies for locations without cable infrastructure, such as outdoor compressor stations.

For a hall with dozens of measuring points and an existing SCADA system, Modbus TCP or OPC UA over a wired network makes sense. For a remote location where cable routing is costly, NB-IoT or LoRaWAN is worthwhile. For critical operations, we recommend a backed-up network path and edge computing, which filters noise directly at the source before the data travels to the cloud.

How to deploy remote monitoring step by step

It makes sense to divide the deployment into five phases that follow one another, each verifying whether continuing makes economic sense.

  1. Compressed air system audit – map the existing compressors, piping, and known weak points.
  2. Selection of metrics and sensors – depending on the type of operation, you determine which variables from the previous table have priority.
  3. Pilot deployment on 1 to 3 machines – verifies the functionality of sensors, data transfer, and notifications in real operation.
  4. Evaluation of key performance indicators (KPI) – you compare energy consumption, number of failures, and downtime duration before and after deployment.
  5. Scaling to the entire operation – once the benefits are confirmed, you expand the system to the remaining machines.

Before starting the pilot, check this checklist:

  • calibration of all sensors against a reference gauge,
  • synchronization of timestamps between sensors and the platform,
  • testing notifications on a simulated deviation,
  • backup of the configuration before going live.

It makes sense to run the pilot for at least four to six weeks in order to cover normal operational fluctuations as well as at least one service intervention. A shorter period usually does not provide enough data for a reliable comparison. The procedure after installation, including bleeding the system, is described in the compressor bleeding guide.

How much remote monitoring costs and when it pays off

How much does remote monitoring cost and when will it pay off — overview diagram

The price is affected by five items: sensors, gateway, installation, software platform licenses, and data connectivity. A service contract for regular inspection and calibration is often added to this.

A simple formula for estimating return on investment looks like this:

  • ROI = (energy savings + reduced repair costs − solution costs) / solution costs

If monitoring detects and fixes a leak that cost the company approximately one fifth of the compressor's output, the energy savings alone will often cover part of the investment within one year. Add to that a lower number of emergency service call-outs thanks to planned maintenance based on the actual condition of the machine, not on a fixed schedule, and the payback period shortens even further. You can find specific savings calculations for specific compressor types in the energy savings guide.

How to secure data between the operational and IT networks

The connection between the operational network (OT) and IT infrastructure is the most common weak point of the entire deployment if it is underestimated from the start.

  1. Network segmentation – compressor monitoring has its own VLAN separated from the rest of the production network.
  2. Transmission encryption – a VPN tunnel or TLS encryption between the gateway and the cloud platform.
  3. Access rights management – each technician has their own login credentials, not a shared account.
  4. Regular firmware updates – gateways and sensors need patches just like computers do.

This includes clear rules for the data itself:

  • the historical data retention period meets the needs of service, typically 12 to 24 months,
  • data ownership clearly remains with the operator, not with the software vendor,
  • service teams have read-only access, not administrator rights, unless necessary,
  • audit logs record every intervention in the alarm configuration.

What to look for when choosing a remote monitoring provider

The provider determines whether the system actually works after installation, or just collects data that nobody evaluates.

  1. Check whether the provider offers local service support, not just hardware sales.
  2. Find out which industrial protocols the provider commonly integrates and whether they have reference installations of a similar scale.
  3. Require a clearly defined SLA for service interventions, including response time in the event of a failure.
  4. Ask about spare parts availability and their delivery time.

Kompresory-vzduchotechnika.cz covers these requirements with a complete offering ranging from turnkey solution design through installation to energy audits and round-the-clock service.

A good provider will propose a pilot verification on one or two machines before offering a quote, rather than immediately supplying sensors for the entire operation. If they don't offer this option, it's more about selling hardware than providing a real solution.

When requesting a quote, ask specifically: how long calibration takes after installation, what format the output data is in, and who handles service when a sensor stops communicating.

Note from technician Zdeněk: what is most often underestimated in practice

The most common mistake when installing sensors is placing them too close to a vibration source, which distorts the measured values and leads to false alarms. Never calibrate right after starting the machine, but only after it has warmed up to operating temperature. One pilot on two machines once showed me a leak that the operator had overlooked for months, because no pressure gauge on the panel displayed it.

How Kompresory-vzduchotechnika.cz will help you with deployment

Kompresory-vzduchotechnika.cz approaches remote monitoring differently than a supplier who just ships a box of sensors. We offer a complete process from an audit of the existing compressed air system through sensor and gateway design, installation, integration into your SCADA network, all the way to an energy audit that calculates the real payback before an investment decision is made.

Compressors-air handling

Standard cooperation begins with a non-binding contact, followed by a technical audit of the operation, design of a pilot solution on one to three machines, and only after its evaluation, delivery for the entire operation. Thanks to our local service network, we handle sensor and gateway failures without weeks of waiting for a spare part.

If you want to find out where your operation is losing the most compressed air, take a look at our pneumatics and hydraulics offer and request a non-binding consultation on the energy audit of your compressor fleet.

Recommended sources and further reading

Frequently Asked Questions

What is remote compressor monitoring?

It is a system of sensors, a gateway and a software platform that continuously monitors the compressor's pressure, temperature, vibrations and other variables and alerts you to deviations via the internet.

Which protocol is the most reliable for monitoring?

It depends on the operation: OPC UA and Modbus TCP are suitable for wired networks and SCADA integration, while NB‑IoT and LoRaWAN are suitable for remote locations without wired infrastructure.

How long does a pilot monitoring deployment take?

A pilot phase on 1 to 3 machines typically lasts 4 to 6 weeks, which covers normal operating fluctuations as well as at least one service intervention.

How much can be saved by detecting leaks?

Industry estimates indicate that unaddressed leaks cost a facility up to approximately one-fifth of the compressed air produced, so their early detection often translates into savings already within the first year.

Where to request installation and servicing of the system?

Kompresory-vzduchotechnika.cz provides the audit, design, installation and continuous servicing of remote monitoring, including an energy audit of your facility.