Spare elements and pressure gauge for BFHP flanged filters

Spare elements and the differential pressure gauge for Omega Air BFHP flanged filters up to 25 bar. The 76090 element is the same for all sizes and differs only in the filtration stage; depending on the size, the filter has 1 to 20 elements. They are the same elements as in the BF flanged filters.
The element determines the filtration stage, and the filter housing is the same for all stages — when replacing, fit an element of the same stage.
Elements by stage
The codes lead to the product pages of the elements.
| Stage | Spare element | Filtration rating | Filter material | Element replacement |
|---|---|---|---|---|
| B coarse filter | BFB-0240V | 15 µm | sintered brass | once a year or at 350 mbar |
| P basic filter | BFP-0240V | 3 µm | acrylic fibres and cellulose | once a year or at 350 mbar |
| R dust filter | BFR-0240V | 1 µm | borosilicate microfibres | once a year or at 350 mbar |
| M fine pre-filter | BFM-0240V | 0.1 µm | borosilicate microfibres | once a year or at 350 mbar |
| S microfilter | BFS-0240V | 0.01 µm | borosilicate microfibres | once a year or at 350 mbar |
| A activated carbon | BFA-0240V | – | activated carbon | within 6 months at the latest |
#showmore#
Number of elements by filter size
| Size | Flange | Flow at 7 bar | Number of elements |
|---|---|---|---|
| 0240 | DN80 | 1,680 Nm³/h | 1 |
| 0300 | DN100 | 3,150 Nm³/h | 2 |
| 0450 | DN125 | 4,700 Nm³/h | 3 |
| 0600 | DN150 | 6,300 Nm³/h | 4 |
| 0900 | DN150 | 9,400 Nm³/h | 6 |
| 1200 | DN200 | 12,550 Nm³/h | 8 |
| 1500 | DN200 | 15,700 Nm³/h | 10 |
| 1800 | DN250 | 18,850 Nm³/h | 12 |
| 2500 | DN250 | 25,100 Nm³/h | 16 |
| 3000 | DN300 | 31,400 Nm³/h | 20 |
When to replace the element
Replace elements B, P, R, M and S once a year, or earlier when the pressure drop reaches 350 mbar. Activated carbon elements A within 6 months at the latest — they are replaced by time, not by pressure drop. According to the manufacturer, the sintered element B can be cleaned in an ultrasonic bath or by back-flushing. Depressurise the filter before replacing the elements.
MDHI 50 differential pressure gauge

The differential pressure gauge shows the pressure drop across the filter elements, so you know when to replace them. It measures a differential pressure of 0 to 1 bar, works up to 50 bar and is mounted on top of the filter. The MDHI 50-K version comes with connecting tubes and fittings for the filter.
Order of stages

In the direction of flow: coarse filter B, basic filter P, dust filter R, fine pre-filter M, microfilter S and activated carbon A. The fine pre-filter M goes before the microfilter S, and the microfilter S before activated carbon A.
Product sorting
List of products
The MDHI 50 differential pressure gauge shows the pressure drop of the filter element on HF filters with pressures up to 50 bar. Range 0 to 1 bar, 2 × G 1/8" connection,...
The MDHI 50-K differential pressure gauge shows the pressure drop of the filter element on HF filters with pressures up to 50 bar. Range 0 to 1 bar, 2 × G 1/8" connection,...
Spare element BFA-0240V for BFA activated carbon filters of all sizes, diameter 90 mm, height 760 mm. Recommended replacement within 6 months at the latest.
Spare element BFB-0240V for BFB coarse filters of all sizes, diameter 90 mm, height 760 mm. Recommended replacement once a year or at a pressure drop of 350 mbar.
Spare element BFM-0240V for BFM fine pre-filters of all sizes, diameter 90 mm, height 760 mm. Recommended replacement at least once a year or at a pressure drop of 350 mbar.
Spare element BFP-0240V for BFP basic filters of all sizes, diameter 90 mm, height 760 mm. Recommended replacement at least once a year or at a pressure drop of 350 mbar.
Spare element BFR-0240V for BFR dust filters of all sizes, diameter 90 mm, height 760 mm. Recommended replacement at least once a year or at a pressure drop of 350 mbar.