Compressed air treatment units: filter, regulator, lubricator, Page 15
-
P2 treatment units
-
Treatment units A2
-
B2 treatment units
-
I3 treatment units
-
I8 treatment units
-
Futura treatment units
-
Combibloc treatment units
-
Standard treatment units
-
Treatment units A1X
Bestsellers
Product sorting
List of products
A replacement FUTURA regulator diaphragm with control piston and sealing ring. Use it when the regulator does not hold pressure or vents continuously. In potentially explosive...
A replacement FUTURA regulator diaphragm with control piston and sealing ring. Use it when the regulator does not hold pressure or vents continuously. In potentially explosive...
A replacement FUTURA regulator diaphragm with control piston and sealing ring. Use it when the regulator does not hold pressure or vents continuously. In potentially explosive...
A replacement sealing cone for the regulator valve of a size 1 COMBIBLOC unit. During maintenance, the cone is removed together with the element; its O-ring and guide pin are...
A replacement spring cover for FUTURA pressure regulators and filter regulators. It serves as a replacement for a damaged cover.
A replacement spring cover for FUTURA pressure regulators and filter regulators. It serves as a replacement for a damaged cover.
A replacement spring cover for FUTURA pressure regulators and filter regulators. It serves as a replacement for a damaged cover.
Replacement polycarbonate filter bowl for A2 units with a 1/2" thread: filter A2F-12, filter regulator A2S-12 and air treatment unit A2U-12.
Replacement polycarbonate filter bowl for A2 units with a 1/4" thread: filter A2F-14, filter regulator A2S-14 and air treatment unit A2U-14.
A replacement bowl for FUTURA filters, filter regulators and units. Replace it when it is damaged or leaking. A damaged bowl may not safely withstand the pressure.
A replacement bowl for FUTURA filters, filter regulators and units. Replace it when it is damaged or leaking. A damaged bowl may not safely withstand the pressure.
A replacement bowl for FUTURA filters, filter regulators and units. Replace it when it is damaged or leaking. A damaged bowl may not safely withstand the pressure.
A replacement bowl for FUTURA filters, filter regulators and units. Replace it when it is damaged or leaking. A damaged bowl may not safely withstand the pressure.
A replacement bowl for FUTURA filters, filter regulators and units. Replace it when it is damaged or leaking. A damaged bowl may not safely withstand the pressure.
A replacement bowl for FUTURA filters, filter regulators and units. Replace it when it is damaged or leaking. A damaged bowl may not safely withstand the pressure.
A replacement bowl for FUTURA filters, filter regulators and units. Replace it when it is damaged or leaking. A damaged bowl may not safely withstand the pressure.
A replacement bowl for FUTURA filters, filter regulators and units. Replace it when it is damaged or leaking. A damaged bowl may not safely withstand the pressure.
A replacement bowl for FUTURA filters, filter regulators and units. Replace it when it is damaged or leaking. A damaged bowl may not safely withstand the pressure.
A replacement bowl for FUTURA filters, filter regulators and units. Replace it when it is damaged or leaking. A damaged bowl may not safely withstand the pressure.
Replacement filter bowl for plastic I3 units with G 1/8" and G 1/4" threads: FWA filters, FDM filter regulators and WE two-piece units.
Replacement polycarbonate lubricator bowl for A2 units with a 3/8" thread: lubricator A2L-38 and air treatment unit A2U-38.
A replacement bowl for FUTURA lubricators and units. It serves as a replacement for a damaged lubricator bowl.
Safety precision pressure regulator FUTURA RP14-10F-SI, size 1: G 1/4" thread, setting range 0.5–10 bar, accuracy ±25 mbar, flow 2,000 l/min, inlet pressure up to 16 bar, with...
Safety precision pressure regulator FUTURA RP14-1F-SI, size 1: G 1/4" thread, setting range 0.1–1 bar, accuracy ±25 mbar, flow 2,000 l/min, inlet pressure up to 16 bar, with...
Safety precision pressure regulator FUTURA RP14-8F-SI, size 1: G 1/4" thread, setting range 0.5–8 bar, accuracy ±25 mbar, flow 2,000 l/min, inlet pressure up to 16 bar, with...
Safety pressure regulator FUTURA R10-8F-SI, size 4: G 1" thread, setting range 0.5–8 bar, flow 14,200 l/min, inlet pressure up to 16 bar, with lockable ball valve and soft-start...
Safety pressure regulator FUTURA R12-8F-SI, size 2: G 1/2" thread, setting range 0.5–8 bar, flow 5,200 l/min, inlet pressure up to 16 bar, with lockable ball valve and...
Safety pressure regulator FUTURA R14-8F-SI, size 1: G 1/4" thread, setting range 0.5–8 bar, flow 2,000 l/min, inlet pressure up to 16 bar, with lockable ball valve and...
Safety pressure regulator FUTURA R34-8F-SI, size 4: G 3/4" thread, setting range 0.5–8 bar, flow 14,200 l/min, inlet pressure up to 16 bar, with lockable ball valve and...
Safety pressure regulator FUTURA R38-8F-SI, size 1: G 3/8" thread, setting range 0.5–8 bar, flow 2,500 l/min, inlet pressure up to 16 bar, with lockable ball valve and...
Safety pressure regulator FUTURA R382-8F-SI, size 2: G 3/8" thread, setting range 0.5–8 bar, flow 4,500 l/min, inlet pressure up to 16 bar, with lockable ball valve and...