Průmyslové vzduchové filtry ISO 8573 pro tlak 20 až 2000 mbar, Page 6
-
Omega air filters; 16 to 64 bar
-
High pressure filters CHP/IHP; carbon and stainless steel up to 400 bar
-
NGF air filtration; including clogging indication
-
Stainless steel process filters; air and gas distribution
-
Sterile stainless steel filters; SFS and SPF filtration
-
Vacuum filters; filtration for vacuum
-
PPA filter system; for painting equipment
-
B-AIR filtration; for breathable air
-
Filters in AFS design; silicone-free filtration
-
Accessories for filters; inserts, indications,...
Product sorting
List of products
Electronic pressure gauge designed to check and monitor the condition of the filter cartridge. The condition of the filter cartridge is determined by the pressure gradient, the...
Replacement cyclone cartridge for liquid water filtration AAFC-60V. Recommended replacement 12 months or every 4,000 MH and upon indication of clogging of the filter element by...
Designed to accurately display the pressure gradient value of the filter cartridge. Dial with coloured fields - red to indicate both wear and tear of the insert. Optimized...
Replacement cyclone cartridge for liquid water filtration AAFC-78V. Recommended replacement 12 months or every 4,000 MH and upon indication of clogging of the filter element by...
AAFR dust filter in 1 1/2" design to remove dust impurities up to 1 um from compressed air according to ISO 8573-1 class 3. Body with easily removable container and designed for...
Float-operated condensate drain valve for compressed air systems up to 20 bar. Version AOK20B for external mounting on the filter body with 1/2" thread.
AAFP basic filter in 3/8" design to remove basic mechanical impurities up to 3 um from compressed air according to ISO 8573-1 class 6. Body with easily removable container and...
AAFC cyclone separator in 1" design with a flow rate of 3,300 l/min for partial removal of condensate from compressed air. Here the flow changes to rotational and due to the...
Electronic IEDs are primarily designed to drain condensed water from filter vessels. Equipped with LED indicator and test button. Operating temperature +1,5 °C to +65 °C,...
The HFS filter insert removes mechanical impurities and oil from the compressed air. Borosilicate microfibre insert with a filtration capacity of up to 0.01 μm. Working pressure...
Hankison 's NGF series SF type basic ISO filter for compressed air. Filter size F07 with 3/4" female thread connection. The filter is equipped with a clogging indicator and an...
Prefilter for compressed air from Hankison NGF series of HF type according to ISO. Filter size F04 with 1/2" female thread connection. The filter is equipped with a clogging...
Electronic timed condensate drain for compressed air systems up to 50 bar, operating on a time switching valve. External mounting on the filter body with 1/2" thread. Simple...
Replacement filter cartridge PFI20 for filter with filtration capacity up to 20 um and working pressure 16 bar. Operating temperature up to 150°C.
The IEDC electronic skimmers with alarm output for remote monitoring and with the possibility of service connection for obtaining operating data from the device are primarily...
Electronic condensate drain from a compressed air system up to 16 bar, operating on a timed valve switching. External mounting on the filter body using a 1/2" thread. Simple...
Replacement microfiltration cartridge with filtration capacity of 0.01 µm for OMEGA AIR AAFS-335 microfilters. Recommended replacement 12 months or every 4,000 MH and when...
AAFS microfilter in 3/8" design to remove micro impurities up to 0.01 um from compressed air according to ISO 8573-1 class 1. Body with easily removable container and designed...
Replacement cyclone cartridge for liquid water filtration AAFC-510V. Recommended replacement 12 months or every 4,000 MH and upon indication of clogging of the filter element by...
Replacement dust filter cartridge with 1 µm filtration capacity for OMEGA AIR AAFR-78 filter. Recommended replacement 12 months or every 4,000 MH and when clogging of the filter...
AAFA activated carbon filter in 1/4" version for absorption of residual oil, oil vapours and aerosols with < 0,005 mg/m3 from compressed air according to ISO 8573-1 class 1....
Kit for wall mounting and connecting filters. The set consists of two angles that are attached to the edges of the filter and allow subsequent mounting on the wall. Connecting...
AAFM pre-filter in 3" design for removal of fine impurities up to 0.1 um from compressed air according to ISO 8573-1 class 2. Body with easily removable container and designed...
AAFS microfilter in 3" design to remove micro impurities up to 0.01 um from compressed air according to ISO 8573-1 class 1. Body with easily removable container and designed for...
Magnetic differential pressure gauge VPG60 for indication of filter cartridge blockage in vacuum systems with LED signaling. Designed for mounting from the top of the filters...
Replacement fine filter cartridge with 0.1 µm filtration capacity for OMEGA AIR AAFM-78 pre-filter. Recommended replacement 12 months or every 4,000 MH and when clogging of the...
AAFM 1 1/2" pre-filter for removing fine impurities up to 0.1 um from compressed air according to ISO 8573-1 class 2. Body with easily removable container and designed for a...
Float-operated condensate drain valve for compressed air systems up to 13 bar. Version AOK13PA for external mounting on the filter body with 1/2" thread.
Replacement basic filter cartridge with 3 µm filtration capacity for OMEGA AIR AAFP-35 and AAFP-60 filters. Recommended replacement 12 months or every 4,000 MH and when clogging...
Kit for wall mounting and connecting filters. The set consists of two angles that are attached to the edges of the filter and allow subsequent mounting on the wall. Connecting...
Electronic time release condensate drain with 24V DC voltage from compressed air system up to 420 bar, working on time switching valve. External mounting on the filter body with...
Replacement sintered bronze 15 µm filter cartridge for OMEGA AIR AAFB-120 filter. Recommended replacement 12 months or every 4,000 MH and when clogging of the filter cartridge...
AAFP basic filter in 3/8" design to remove basic mechanical impurities up to 3 um from compressed air according to ISO 8573-1 class 6. Body with easily removable container and...
Replacement fine filter cartridge with 0.1 µm filtration capacity for OMEGA AIR AAFM-780 pre-filter. Recommended replacement 12 months or every 4,000 MH and when clogging of the...
Replacement microfilter cartridge with filtration capacity of 0.01 µm for OMEGA AIR AAFS-25 and AAFS-30 microfilters. Recommended replacement 12 months or every 4,000 MH and...
AAFC cyclone separator in 3" design with a flow rate of 36,000 l/min for partial removal of condensate from compressed air. Here the flow changes to rotational and due to the...
Replacement filter with activated carbon AAFA2 for OMEGA AIR AAFA2-198. Use as a filter to remove residual oil content of oil vapours and aerosols with < 0.005 mg/m3from...
Electronic timed condensate drain for compressed air systems up to 150 bar, operating on a time switching valve. External mounting on the filter body with 1/2" thread. Simple...