Pressure vessels and air receivers 4000 l

A 4000 l air receiver can be chosen from five vertical pressure vessels: two rated down to −20 °C for 12 and 16 bar, two high-pressure vessels for 32 and 42 bar and one oxygen vessel for 12 bar. All five are made of carbon steel to Directive 2014/68/EU on pressure equipment (PED).
Standard air receivers for heated compressor rooms go up to 3000 l. From 4000 l upwards, our range only includes vessels that withstand frost and are also intended for group 1 fluids, including oxygen. You will find smaller volumes and the other versions in our overview of all pressure vessels and air receivers.
Five 4000 l air receivers side by side
All five have the same diameter and height, so they take up the same space, but for the high-pressure vessels the floor has to carry more weight. They differ in pressure and finish; you will find the dimensions and connections on the product pages of the vessels.
| Pressure vessels and air receivers 4000 l | |||||
|---|---|---|---|---|---|
| Vessel or kit | Design | Finish | Working pressure | Medium | Category |
| Vertical pressure vessel for oxygen 4000 l - 12 bar | vertical | white RAL 9010 paint, ALM inside | 12 bar | oxygen | Oxygen vessels |
| Vertical low-temperature pressure vessel for fluids 4000 l - 12 bar | vertical | paint, hot-dip zinc or ALM | 12 bar | air, oil, nitrogen, oxygen, argon or helium | Vessels down to −20 °C and for group 1 fluids |
| Vertical low-temperature pressure vessel for fluids 4000 l - 16 bar | vertical | paint, hot-dip zinc or ALM | 16 bar | air, oil, nitrogen, oxygen, argon or helium | Vessels down to −20 °C and for group 1 fluids |
| Vertical pressure vessel 4000 l - 32 bar | vertical | paint or hot-dip zinc | 32 bar | air, oil, nitrogen, oxygen, argon or helium | High-pressure vessels for 32 and 42 bar |
| Vertical pressure vessel 4000 l - 42 bar | vertical | paint or hot-dip zinc | 42 bar | air, oil, nitrogen, oxygen, argon or helium | High-pressure vessels for 32 and 42 bar |
The 12- and 16-bar vessels are made painted, galvanised or with the ALM internal coating, and the high-pressure vessels painted or galvanised. The oxygen vessel always has white RAL 9010 paint and the ALM coating inside.
#showmore#
Which pressure to choose
The pressure on the vessel’s data plate must be at least as high as the maximum pressure that can enter it. A compressor that cuts out at no more than 11 bar goes with a 12-bar vessel. If it cuts out higher, it needs a 16-bar vessel.
A 32-bar vessel belongs downstream of a high-pressure compressor, and a 42-bar vessel serves pipework with an even higher pressure, for example in the PET industry or at test stations. All of them withstand temperatures from −20 °C; the upper limit is +80 °C, and +100 °C for the 32-bar vessel.
The safety valve must open at no more than the vessel’s pressure rating and must be able to discharge the full output of the compressor. How to match the volume and pressure of the vessel to the compressor is explained in our advice centre on choosing an air receiver.
A tank for compressed air, nitrogen and oxygen
Both the vessels rated down to −20 °C and the high-pressure vessels are intended for group 1 fluids except hydrogen, so besides compressed air and nitrogen they can hold argon, helium, oil and even oxygen. They are suitable as the central air receiver of a compressor station, or as a nitrogen or oxygen reservoir downstream of a generator.
The oxygen vessel VVA4000-12-OX is intended for oxygen and other group 1 fluids; for compressed air, choose another vessel. It differs from the VVP4000-12 of the same size in its finish: it is always white on the outside (RAL 9010 powder coating) and has a baked ALM epoxy coating inside.
With oxygen, the fittings, seals and lubricants must also be designed for oxygen. Neither oil nor grease must come into contact with oxygen.


Outdoors, in frost and on dampers
All five vessels withstand frost down to −20 °C, so they can stand outdoors or in a hall that is not heated in winter. The galvanised version is best suited to outdoor use, and in frost the condensate needs to be drained before it freezes.
Vibration dampers belong under the foot plates, and the vessel is not rigidly anchored to the floor or to any structure.
The vessels bear the CE marking and come with a declaration of conformity and instructions for use and maintenance. Inspections and their intervals are set by national regulations according to the vessel’s volume and pressure; you will find an overview for the Czech Republic in our article on inspection intervals.
Where next: neighbouring volumes and parameters
The smaller and larger sizes, plus overviews by pressure, finish and directive in which 4000 l vessels are listed together with other volumes.
| Neighbouring volumes and related pages | ||
|---|---|---|
| Page | What you will find | Items |
| Pressure vessels 3000 l | smaller volume, plus standard and horizontal vessels, a stainless steel and a vacuum vessel | 14 |
| Pressure vessels 5000 l | larger volume, with an 8-bar vessel as well | 6 |
| Pressure vessels for 16 bar | 16-bar vessels from 270 to 10000 l | 19 |
| Vessels with ALM coating | for contact with food, including oxygen vessels | 38 |
| Galvanised vessels | hot-dip galvanised vessels for outdoor use and damp conditions | 78 |
| Vessels to the Pressure Equipment Directive (PED) | large, stainless steel, high-pressure and oxygen vessels | 87 |
Ventilek’s tip
Fit the vessel only with fittings rated for the same pressure. The safety valve, the pressure gauge, the shut-off valves and the hoses must all withstand the pressure on the vessel’s data plate. A single part rated for a lower pressure is the weakest point of the entire pipework.
- Is a 4000 l air receiver vertical or horizontal?
- Vertical. All five 4000 l vessels are vertical and have the same diameter and height.
- Which 4000 l vessel for a compressor up to 10 bar?
- A 12-bar vessel: painted for a dry hall, galvanised for outdoors or damp conditions, and with the ALM coating where the air comes into contact with food.
- Which 4000 l vessels are suitable for oxygen?
- All of them. The oxygen vessel is white and has the ALM coating inside, but the vessels rated down to −20 °C and the high-pressure vessels can also take oxygen. The fittings, seals and lubricants must be designed for oxygen.
- Do the vessels have an inspection opening?
- Not as standard; all connections are threaded. For the high-pressure and oxygen vessels, the manufacturer can supply a handhole or a manhole on request.
- Does a 4000 l vessel need regular inspections?
- Yes. It is pressure equipment under the PED, and the types of inspection and their intervals are set by national regulations.
Send us the output and cut-out pressure of your compressor and the medium you want to store. We will recommend which of the 4000-litre vessels suits them.
Product sorting
List of products
A vertical pressure vessel for oxygen, 4000 l at 12 bar, for a central oxygen reserve. White RAL 9010 paint, ALM epoxy coating inside.