Pressure vessels and air receivers 8000 l

Pressure vessels of 8000 l come in two pressure ratings: the VVP8000-8 for 8 bar and the VVP8000-12 for 12 bar. Both are vertical and the same size, withstand frost down to −20 °C and are made painted in RAL 5015 or hot-dip galvanised.
The 12-bar vessel serves as the central air receiver of an operation with a large and variable air demand, where the compressors need time to start up. The 8-bar vessel is a large reservoir for lower-pressure networks, downstream of low-pressure compressors or nitrogen and oxygen generators.
Both can hold compressed air, nitrogen, argon, helium, oil and even oxygen. All the other sizes and categories are shown in our overview of pressure vessels and air receivers.
8000 l vessels: 8 or 12 bar
Both have the same diameter and height and the same finishes. They differ in pressure and in the source they go with.
| Pressure vessels and air receivers 8000 l | |||||
|---|---|---|---|---|---|
| Vessel or kit | Design | Finish | Working pressure | Medium | Category |
| Vertical low-temperature pressure vessel for fluids 8000 l - 8 bar | vertical | paint or hot-dip zinc | 8 bar | air, oil, nitrogen, oxygen, argon or helium | Vessels down to −20 °C and for group 1 fluids |
| Vertical low-temperature pressure vessel for fluids 8000 l - 12 bar | vertical | paint or hot-dip zinc | 12 bar | air, oil, nitrogen, oxygen, argon or helium | Vessels down to −20 °C and for group 1 fluids |
We do not offer an 8000 l vessel for 16 bar. For 16 bar, choose a volume of 6000 or 10000 l.
#showmore#
When 8 bar is enough
The 8-bar vessel is for systems that work at no more than 8 bar. Neither the compressor nor the generator may deliver more into it, so set the safety valve no higher than 8 bar.
The 12-bar vessel goes with a compressor whose cut-out pressure is no more than 11 bar. In both cases, the flow capacity of the safety valve must cover the full output of the compressor or generator.
How to derive the size of the air receiver from the compressor output and the pattern of air demand is explained in our advice centre on choosing a pressure vessel.
Finish, frost and condensate
For a dry or heated hall, the painted VVP vessel with its external RAL 5015 powder coating is enough. For outdoors and damp conditions, the galvanised VVG, hot-dip galvanised inside and out, is a better choice.
The working temperature is −20 to +80 °C, so the vessel can also stand outdoors. In winter, keep an eye on the condensate so that it does not freeze in the bottom connection, and drain it regularly, by hand for example with a condensate drain valve.

Fittings and inspections
The vessels are supplied without fittings. As a minimum, they need a safety valve, a pressure gauge, a shut-off valve and a condensate drain, all designed for the medium the vessel will hold.
Both vessels are manufactured to Directive 2014/68/EU on pressure equipment (PED). Inspections and their intervals are set by national regulations; what an operator in the Czech Republic must arrange is described in our article on operator obligations.
Other sizes and overviews
The neighbouring volumes of 6000 and 10000 l, and the overviews of 12-bar vessels, painted vessels and vessels to the PED, which also include the 8000 l vessels.
| Where next from the 8000 l vessels | ||
|---|---|---|
| Page | What you will find | Items |
| Pressure vessels 6000 l | smaller volume, for 12 and 16 bar | 2 |
| Pressure vessels 10000 l | the largest volume, for 8, 12 and 16 bar | 3 |
| Pressure vessels for 12 bar | 12-bar vessels, including oxygen and fully equipped ones | 29 |
| Painted vessels | painted vessels from 5 to 10000 l | 112 |
| Vessels to the Pressure Equipment Directive (PED) | pressure equipment to Directive 2014/68/EU | 87 |
Ventilek’s tip
Dampers, not bolts. The vessel is not rigidly anchored to the floor or to any structure. Vibration dampers belong under the three foot plates, and vibration from the compressor is then not transmitted to the welds.
- Where can I find a vessel of around 8000 l for 16 bar?
- For 16 bar, the nearest volumes are 6000 and 10000 l. The 8000 l vessel is offered only for 8 and 12 bar.
- What can I store in the vessel?
- Compressed air, nitrogen, argon, helium, oil and oxygen, that is, also group 1 fluids except hydrogen.
- Does the vessel have an inspection opening?
- No, the standard vessel only has threaded connections.
- What pressure should the safety valve be set to?
- No higher than the pressure on the vessel’s data plate, i.e. 8 or 12 bar. Its flow capacity must cover the full output of the compressor or generator.
Deciding between 8 and 12 bar? Tell us what pressure your network needs and what you will store in the vessel. You can choose a compressor for the vessel in our overview of compressors.