Manifold module B2T-2 in size 2 for B2 units with 3/8" and 1/2" threads: four G 1/4" branch ports, dimensions 20 × 60 × 60 mm. It takes air from within the assembly, for example...
A2 compressed air pressure regulator with a G 1/2" thread, inlet pressure up to 10 bar and a setting range of 0.5 to 8.5 bar. Flow 6000 l/min, painted aluminium body, pressure...
Compact plastic I3 compressed air filter with a G 1/4" thread and a 20 µm element, inlet pressure up to 13 bar. Flow 1200 l/min, transparent 16 cm³ bowl with semi-automatic...
Replacement metal lubricator bowl NOK3 with sight glass, volume 379 cm³, for I8 units with thread 3/4" and 1": N34, N10.
Spare mounting bracket for the A2 regulator A2R-12 and filter regulator A2S-12 in size 1/2". Use it to fix the regulator to a wall.
A2 filter regulator with a G 1" thread: 5 µm sintered bronze element, setting 0.5 to 8.5 bar, inlet pressure up to 10 bar, flow 7000 l/min. Semi-automatic drain, pressure gauge...
Two-piece B2 compressed air treatment unit with a G 3/4" thread: pressure regulator with 20 µm filter and lubricator. Inlet pressure up to 18 bar, setting 0 to 12 bar, flow 4600...
Metal B2 compressed air microfilter with a G 1/2" thread and 0.01 µm filtration for pressure up to 18 bar. Flow 4300 l/min, manual condensate drain. It is always installed after...
Replacement NBR regulator diaphragm for A2 units with a 1/4" thread: regulator A2R-14, filter regulator A2S-14 and air treatment unit A2U-14.
The mounting bracket with screws fixes a single FUTURA component to a wall or machine frame. Remove the rear cover plate of the component before mounting. The bracket holds the...
A2 compressed air filter with a G 1" thread and a 5 µm sintered bronze element. Inlet pressure up to 10 bar, flow 7000 l/min, 130 cm³ polycarbonate bowl with semi-automatic...
Miniature plastic compressed air filter with a G 1/4" thread for pressure up to 12 bar. Filter rating 20 µm, flow 1200 l/min, 16 cm³ bowl with manual condensate drain.
Metal B2 compressed air microfilter with a G 3/8" thread and 0.01 µm filtration for pressure up to 18 bar. Flow 4300 l/min, manual condensate drain. It is always installed after...
Replacement NBR regulator diaphragm for A2 units with a 3/8" thread: regulator A2R-38, filter regulator A2S-38 and air treatment unit A2U-38.
Connection kit B2CK-2 for two components of B2 air treatment units in size 2 with 3/8" and 1/2" threads: two screws and a sealing ring. It joins a filter, regulator, lubricator...
Two-piece B2 compressed air treatment unit with a G 3/8" thread: pressure regulator with 20 µm filter and lubricator. Inlet pressure up to 18 bar, setting 0 to 12 bar, flow 2500...
Replacement polycarbonate lubricator bowl for A2 units with a 1/2" thread: lubricator A2L-12 and air treatment unit A2U-12.
The connection kit with bracket joins two FUTURA components of the same size and at the same time fixes the unit to a wall. For an assembly of three to four components, two kits...
Replacement polycarbonate lubricator bowl for A2 units with a 1" thread: lubricator A2L-10 and air treatment unit A2U-10.
Replacement polycarbonate filter bowl for A2 units with a 3/8" thread: filter A2F-38, filter regulator A2S-38 and air treatment unit A2U-38.
Replacement polycarbonate filter bowl for A2 units with a 1" thread: filter A2F-10, filter regulator A2S-10 and air treatment unit A2U-10.
Replacement NBR regulator diaphragm for A2 units with a 1/2" thread: regulator A2R-12, filter regulator A2S-12 and air treatment unit A2U-12.
A replacement sintered 5 µm filter element for FUTURA filters and filter regulators, and also for the filters in units. The element gradually clogs. Replace it when the pressure...
Ball valve with exhaust FUTURA K38-F, size 1: G 3/8" thread, flow 1,900 l/min, inlet pressure up to 16 bar, for ATEX environments.
Metal I8 compressed air lubricator (air line oiler) with a G 1" thread, inlet pressure up to 18 bar and a flow of 16000 l/min. Metal 379 cm³ oil bowl, fine dose adjustment with...
A2 compressed air filter with a G 1/4" thread and a 5 µm sintered bronze element. Inlet pressure up to 10 bar, flow 750 l/min, 15 cm³ polycarbonate bowl with semi-automatic...
Metal B2 compressed air microfilter with a G 1/4" thread and 0.01 µm filtration for pressure up to 18 bar. Flow 1750 l/min, manual condensate drain. It is always installed after...
A2 compressed air filter with a G 3/8" thread and a 5 µm sintered bronze element. Inlet pressure up to 10 bar, flow 1500 l/min, 20 cm³ polycarbonate bowl with semi-automatic...
The connection kit joins two FUTURA components of the same size regardless of their thread. It contains two frames, screws and a sealing ring. This lets you assemble a unit from...
Two-piece B2 compressed air treatment unit with a G 1" thread: pressure regulator with 20 µm filter and lubricator. Inlet pressure up to 18 bar, setting 0 to 12 bar, flow 4600...
Metal B2 compressed air lubricator (air line oiler) with a G 3/4" thread, inlet pressure up to 18 bar and a flow of 16000 l/min. The oil dose is set with the screw on top;...
Metal B2 compressed air lubricator (air line oiler) with a G 1" thread, inlet pressure up to 18 bar and a flow of 16000 l/min. The oil dose is set with the screw on top; painted...
Mounting bracket for the A2 filter A2F-12 and lubricator A2L-12 in size 1/2". Use it to fix the filter or lubricator to a wall.
Ball valve with exhaust FUTURA K14-F, size 1: G 1/4" thread, flow 1,900 l/min, inlet pressure up to 16 bar, for ATEX environments.
Pilot-operated metal B2 pressure regulator with a G 1/2" thread, inlet pressure up to 18 bar and a flow of 4500 l/min. The outlet pressure is set by an air signal through the G...
A replacement bowl for FUTURA activated carbon filters. It has no drain, because the activated carbon filter does not drain condensate. It serves as a replacement for a damaged...