Compressed air filtration pressure 16 to 64 bar, Page 5
-
Professional air filtration AAF; threaded version up to 16 bar
-
Professional air filtration BF; flanged version up to 16 bar
-
HF professional filtration; threaded version up to 50 bar
Bestsellers

AFM filters are used to remove the largest mechanical impurities from compressed air up to 0.1 um according to ISO 8573-1 class 2. Body with easily removable container and...

AFM filters are used to remove the largest mechanical impurities from compressed air up to 0.1 um according to ISO 8573-1 class 2. Body with easily removable container and...

Replacement catalytic filters (hopcalite) for OMEGA AIR - AAFH2-198. Suitable for removing CO andCO2 to the level of breathable air from compressed air according to ISO 8573-1...

Replacement filter with activated carbon AAFA2 for OMEGA AIR AAFA2-780. Use as a filter to remove residual oil content of oil vapours and aerosols with < 0.005 mg/m3from...

Replacement microfilter cartridge with filtration capacity of 0.01 µm for OMEGA AIR AAFS-1000 microfilters. Recommended replacement 12 months or every 4,000 MH and when clogging...

Replacement microfilter cartridge with filtration capacity of 0.01 µm for OMEGA AIR AAFS-1500 and AAFS-1680 microfilters. Recommended replacement 12 months or every 4,000 MH and...

Service kit for condensate evacuator IED for eelectronic IED triggers. The devices are primarily designed to drain condensed water from the filter vessels.

Replacement fine filter cartridge with 0.1 µm filtration capacity for OMEGA AIR AAFM-35 and AAFM-60 pre-filters. Recommended replacement 12 months or every 4,000 MH and when...

AAFC cyclone separator in 3" design with a flow rate of 36,000 l/min for partial removal of condensate from compressed air. Here the flow changes to rotational and due to the...

Replacement filter with activated carbon AAFA for OMEGA AIR AAFA-120. Absorption of residual oil, oil vapours and aerosols with a content of < 0.005 mg/m³ from compressed air...

AAFM pre-filter in 2" design for removal of fine impurities up to 0.1 um from compressed air according to ISO 8573-1 class 2. Body with easily removable container and designed...

Replacement basic filter cartridge with 3 µm filtration capacity for OMEGA AIR AAFP-120 filter. Recommended replacement 12 months or every 4,000 MH and when clogging of the...

Replacement microfiltration cartridge with filtration capacity of 0.01 µm for OMEGA AIR AAFS-335 microfilters. Recommended replacement 12 months or every 4,000 MH and when...

AAFM 1 1/2" pre-filter for removing fine impurities up to 0.1 um from compressed air according to ISO 8573-1 class 2. Body with easily removable container and designed for a...

AAFA 2" activated carbon filter for absorption of residual oil, oil vapours and aerosols with < 0,005 mg/m3 from compressed air according to ISO 8573-1 class 1. Body with easily...

Electronic timed condensate drain for compressed air systems up to 50 bar, operating on a time switching valve. External mounting on the filter body with 1/2" thread. Simple...

AAFB 2" coarse filter for removal of the largest mechanical impurities up to 15 um from compressed air according to ISO 8573-1 class 7. Body with easily removable container and...

Removes mechanical dirt up to 0.01 um and oil according to ISO 8573-1 class 1. Connection with internal pipe threads 1 1/2". The design allows a flow rate of up to 6667 l/min....

AAFA 2" activated carbon filter for absorption of residual oil, oil vapours and aerosols with < 0,005 mg/m3 from compressed air according to ISO 8573-1 class 1. Body with easily...

AAFM pre-filter in 3" design for removal of fine impurities up to 0.1 um from compressed air according to ISO 8573-1 class 2. Body with easily removable container and designed...

AAFMS2 1 1/2" molecular sieve capsule filter designed to prevent moisture leakage into the air during shutdown of adsorption dryers according to ISO 8573-1 class 1. Body with...

AAFMS2 1 1/2" molecular sieve capsule filter designed to prevent moisture leakage into the air during shutdown of adsorption dryers according to ISO 8573-1 class 1. Body with...

Removes mechanical dirt up to 0.01 um and oil according to ISO 8573-1 class 1. Connection by internal pipe threads 1". The design allows a flow rate of up to 3400 l/min. Special...

Removes mechanical dirt up to 0.01 um and oil according to ISO 8573-1 class 1. Connection by internal pipe threads 1/2". The design allows a flow rate of up to 1187 l/min....

Removes mechanical dirt up to 0.01 um and oil according to ISO 8573-1 class 1. Connection with 2" internal pipe threads. The design allows a flow rate of up to 13,317 l/min....

Removes mechanical dirt up to 0.01 um and oil according to ISO 8573-1 class 1. Connection with 2" internal pipe threads. The design allows a flow rate of up to 8233 l/min....

Removes mechanical dirt up to 0.01 um and oil according to ISO 8573-1 class 1. Connection with 3/4" internal pipe threads. The design allows a flow rate of up to 1867 l/min....

Adsorption filter with activated carbon AAFA2 in 1 1/2" version for absorption of residual oil, oil vapours and aerosols with < 0,005 mg/m3 from compressed air according to ISO...

Adsorption filter with activated carbon AAFA2 in 1 1/2" version for absorption of residual oil, oil vapours and aerosols with < 0,005 mg/m3 from compressed air according to ISO...

Adsorption filter with activated carbon AAFA2 in 1" version for absorption of residual oil, oil vapours and aerosols with < 0,005 mg/m3 from compressed air according to ISO...

Adsorption filter with activated carbon AAFA2 in 1" version for absorption of residual oil, oil vapours and aerosols with < 0,005 mg/m3 from compressed air according to ISO...

Float-operated condensate drain valve for compressed air systems up to 20 bar. Version AOK20B for external mounting on the filter body with 1/2" thread.

AAFP 1" basic filter for removal of basic mechanical impurities up to 3 um from compressed air according to ISO 8573-1 class 6. Body with easily removable container and designed...

AAFP basic filter in 3" design to remove basic mechanical impurities up to 3 um from compressed air according to ISO 8573-1 class 6. Body with easily removable container and...

Removes mechanical contaminants up to 3 um in size according to ISO 8573-1 class 6. Connection with internal pipe threads 1 1/2". Designed to allow flow rates up to 6667 l/min....

Removes mechanical contaminants up to 3 um in size according to ISO 8573-1 class 6. Connection with internal pipe threads 1 1/2". The design allows flow rates up to 4700 l/min....

Removes mechanical contaminants up to 3 um in size according to ISO 8573-1 class 6. Connection by internal pipe threads 1". The design allows flow rates up to 3400 l/min....

Removes mechanical contaminants up to 3 um in size according to ISO 8573-1 class 6. Connection by internal pipe threads 1/2". Designed to allow flow rates up to 1187 l/min....

Removes mechanical contaminants up to 3 um in size according to ISO 8573-1 class 6. Connection with 2" internal pipe threads. Designed to allow flow rates up to 13,317 l/min....

Removes mechanical contaminants up to 3 um in size according to ISO 8573-1 class 6. Connection with 2" internal pipe threads. Designed for flow rates up to 8233 l/min. Special...