Industrial compressed air filters ISO 8573.1
Get rid of mechanical impurities and oil from compressed air efficiently with our extensive filtration programme. Not only will you get better quality compressed air to suit more applications, but you will also extend the life of many compressor system components. If the above matters to you, please feel free to explore our filtration category properly. You will find Omega Air filters, B-Air filters or NGF and Mark filters. We also offer new filter, catalyst and adsorption inserts for all filters. More about the whole program and filtering principles in the sequel.
#ShowMore#
Why is it necessary to filter compressed air?
The compressed air produced by your compressor - whether piston or screw - is not of good quality without post-treatment and is not suitable for many applications. This is because the compressor inlet filter only captures part of the mechanical impurities. However, they are not the only problem that degrades the quality of the produced air.
What does the produced compressed air contain?
- mechanical impurities
- humidity
- oil vapours (if it is an oil compressor)
This harmful triple combination is causing great trouble for any equipment that is connected to the compressor. Pneumatic tools - over time, they lose power and increase consumption, corrode inside, destroy seals, clog holes, become stuck and negatively affect the quality of work. Its lifetime is shortened many times over. Imagine what untreated compressed air can do to the individual components of a large automated line full of valves, cylinders and variously controlled moving parts. Shutting down a line for servicing can cost a company hundreds of thousands.
Compressed air quality
Compressed air quality is described in standardsiSO 8573-1 with seven classes, from 0 to 6. This guideline is crucial for every operator, as it sets out the exact quality requirements for different applications. Each class has a prescribed maximum content of solids, water and oil. We go into detail about this issue in this article, which will give you advice on how to choose water filters to connect behind your compressor: How to filter compressed air
In addition to the filters themselves, you may also be interested in:
- filter inserts for activated carbon filters
- filter inserts for microfilters
- filter inserts for dust filters
- catalytic filter inserts
- adsorption filter inserts
- air filter cartridge contamination indicators
Filters according to the quality class of solid impurities:
- quality class 1
- quality class 2
- quality class 3
- quality class 4
- quality class 5
- quality class 6
- quality class 7
Industrial filters divided according to condensate discharge:
-
Omega air filters; 16 to 64 bar
-
High pressure filters CHP/IHP; carbon and stainless steel up to 400 bar
-
NGF air filtration; including clogging indication
-
Stainless steel process filters; air and gas distribution
-
Sterile stainless steel filters; SFS and SPF filtration
-
Vacuum filters; filtration for vacuum
-
PPA filter system; for painting equipment
-
B-AIR filtration; for breathable air
-
Filters in AFS design; silicone-free filtration
-
Accessories for filters; inserts, indications,...
Bestsellers

Replacement cyclone insert for liquid water filtration AAFC-120V. Recommended replacement 12 months or every 4,000 MH and upon indication of clogging of the filter element by...

AAFC cyclone separator in 1/2" design with a flow rate of 1,300 l/min for partial removal of condensate from compressed air. Here the flow changes to rotational and due to the...

The set allows the combination of 2 filters with different filtration capabilities into one block. Reduction of space required for installation. For filtration sizes AF-33 to...

The set allows the combination of 3 filters with different filtration capabilities into one block. Reduction of space required for installation. For filtration sizes AF-33 to...

AAFC cyclone separator in 3/8" design with a flow rate of 1,000 l/min for partial removal of condensate from compressed air. Here the flow changes to rotational and due to the...

Replacement cyclone cartridge for liquid water filtration AAFC-60V. Recommended replacement 12 months or every 4,000 MH and upon indication of clogging of the filter element by...

Replacement cyclone cartridge for liquid water filtration AAFC-78V. Recommended replacement 12 months or every 4,000 MH and upon indication of clogging of the filter element by...

Hankison 's NGF series SF type basic ISO filter for compressed air. Filter size F02 with 1/4" female thread connection. The filter is equipped with a clogging indicator and an...

MDM40 - basic version. Magnetic differential pressure gauges for displaying the orientation state of the filter cartridge. Fitted with dial with indicative scale and green/red...

Wall mounting kit. The set consists of angles that are attached to the edges of the filter and allow subsequent mounting on the wall. Fast and elegant installation that everyone...

AAFC cyclone separator in 3/4" design with a flow rate of 2,000 l/min for partial removal of condensate from compressed air. Here the flow changes to rotational and due to the...

Replacement fine filter cartridge with 0.1 µm filtration capacity for OMEGA AIR AAFM-35 and AAFM-60 pre-filters. Recommended replacement 12 months or every 4,000 MH and when...

Wall mounting kit. The set consists of angles that are attached to the edges of the filter and allow subsequent mounting on the wall. Fast and elegant installation that everyone...

Designed to accurately display the pressure gradient value of the filter cartridge. Dial with coloured fields - red to indicate both wear and tear of the insert. Optimized...

Replacement microfilter cartridge with filtration capacity of 0.01 µm for OMEGA AIR AAFS-25 and AAFS-30 microfilters. Recommended replacement 12 months or every 4,000 MH and...

AFM filters are used to remove the largest mechanical impurities from compressed air up to 0.1 um according to ISO 8573-1 class 2. Body with easily removable container and...

Dust filter AAFR in 1/2" design to remove dust impurities up to 1 um from compressed air according to ISO 8573-1 class 3. Body with easily removable container and designed for a...

Replacement cyclone cartridge for liquid water filtration AAFC-510V. Recommended replacement 12 months or every 4,000 MH and upon indication of clogging of the filter element by...

AAFC cyclone separator in 1" design with a flow rate of 3,300 l/min for partial removal of condensate from compressed air. Here the flow changes to rotational and due to the...

AFM filters are used to remove the largest mechanical impurities from compressed air up to 0.1 um according to ISO 8573-1 class 2. Body with easily removable container and...

AAFM pre-filter in 2 1/2" design to remove fine impurities up to 0.1 um from compressed air according to ISO 8573-1 class 2. Body with easily removable container and designed...

AAFC cyclone separator in 1 1/2" design with a flow rate of 8,500 l/min for partial removal of condensate from compressed air. Here the flow changes to rotational and due to the...

AAFA activated carbon filter in 1/4" version for absorption of residual oil, oil vapours and aerosols with < 0,005 mg/m3 from compressed air according to ISO 8573-1 class 1....

Electronic condensate drain from a compressed air system up to 16 bar, operating on a timed valve switching. External mounting on the filter body using a 1/2" thread. Simple...

AAFM 1 1/2" pre-filter for removing fine impurities up to 0.1 um from compressed air according to ISO 8573-1 class 2. Body with easily removable container and designed for a...

Magnetic differential pressure gauges to indicate the pressure gradient of the filter cartridge. MDM60E - equipped with LED signalling when the insert is dropped. Designed for...

AAFA activated carbon filter in 1/4" version for absorption of residual oil, oil vapours and aerosols with < 0,005 mg/m3 from compressed air according to ISO 8573-1 class 1....

Replacement cyclone cartridge for liquid water filtration AAFC-198V. Recommended replacement 12 months or every 4,000 MH and upon indication of clogging of the filter element by...

AAFC 2" cyclone separator with a flow rate of 16,667 l/min for partial removal of condensate from compressed air. Here the flow changes to rotational and due to the rotation and...

AAFS 2 1/2" microfilter for removal of micro impurities up to 0.01 um from compressed air according to ISO 8573-1 class 1. Body with easily removable container and designed for...

AAFP basic filter in 2 1/2" design to remove basic mechanical impurities up to 3 um from compressed air according to ISO 8573-1 class 6. Body with easily removable container and...

Connection set for easy connection of two or more filters into one block in 1/2" threaded design. Universal design allowing the connection of filters from different...

Replacement filter with activated carbon AAFA2 for OMEGA AIR AAFA2-120. Use as a filter to remove residual oil content of oil vapours and aerosols with < 0.005 mg/m3from...

Hankison filter cartridge for HF series air filter type F02. The filter insert is suitable for easy replacement by means of a thread in the filter. The maximum pressure of the...

Replacement fine filter cartridge with 0.1 µm filtration capacity for OMEGA AIR AAFM-25 and AAFM-30 pre-filters. Recommended replacement 12 months or every 4,000 MH and when...

AAFA activated carbon filter in 1/2" version for absorption of residual oil, oil vapours and aerosols with < 0,005 mg/m3 from compressed air according to ISO 8573-1 class 1....

Replacement sintered bronze 15 µm filter cartridge for OMEGA AIR AAFB-1000 filter. Recommended replacement 12 months or every 4,000 MH and when clogging of the filter cartridge...

Replacement microfilter cartridge with filtration capacity 0,01 µm for OMEGA AIR AAFS-198 microfilters. Recommended replacement 12 months or every 4,000 MH and when clogging of...

Replacement dust filter cartridge with 1 µm filtration capacity for OMEGA AIR AAFR-25 and AAFR-30 filters. Recommended replacement 12 months or every 4,000 MH and when clogging...

Replacement filter with capsule and molecular sieve for OMEGA AIR - AAFH2-120. Designed as a fuse against moisture leakage into the air during shutdown of ISO 8573-1 class 1...