Industrial compressed air filters ISO 8573.1
Get rid of mechanical impurities and oil from compressed air efficiently with our extensive filtration programme. Not only will you get better quality compressed air to suit more applications, but you will also extend the life of many compressor system components. If the above matters to you, please feel free to explore our filtration category properly. You will find Omega Air filters, B-Air filters or NGF and Mark filters. We also offer new filter, catalyst and adsorption inserts for all filters. More about the whole program and filtering principles in the sequel.
#ShowMore#
Why is it necessary to filter compressed air?
The compressed air produced by your compressor - whether piston or screw - is not of good quality without post-treatment and is not suitable for many applications. This is because the compressor inlet filter only captures part of the mechanical impurities. However, they are not the only problem that degrades the quality of the produced air.
What does the produced compressed air contain?
- mechanical impurities
- humidity
- oil vapours (if it is an oil compressor)
This harmful triple combination is causing great trouble for any equipment that is connected to the compressor. Pneumatic tools - over time, they lose power and increase consumption, corrode inside, destroy seals, clog holes, become stuck and negatively affect the quality of work. Its lifetime is shortened many times over. Imagine what untreated compressed air can do to the individual components of a large automated line full of valves, cylinders and variously controlled moving parts. Shutting down a line for servicing can cost a company hundreds of thousands.
Compressed air quality
Compressed air quality is described in standardsiSO 8573-1 with seven classes, from 0 to 6. This guideline is crucial for every operator, as it sets out the exact quality requirements for different applications. Each class has a prescribed maximum content of solids, water and oil. We go into detail about this issue in this article, which will give you advice on how to choose water filters to connect behind your compressor: How to filter compressed air
In addition to the filters themselves, you may also be interested in:
- filter inserts for activated carbon filters
- filter inserts for microfilters
- filter inserts for dust filters
- catalytic filter inserts
- adsorption filter inserts
- air filter cartridge contamination indicators
Filters according to the quality class of solid impurities:
- quality class 1
- quality class 2
- quality class 3
- quality class 4
- quality class 5
- quality class 6
- quality class 7
Industrial filters divided according to condensate discharge:
-
Omega air filters; 16 to 64 bar
-
High pressure filters CHP/IHP; carbon and stainless steel up to 400 bar
-
NGF air filtration; including clogging indication
-
Stainless steel process filters; air and gas distribution
-
Sterile stainless steel filters; SFS and SPF filtration
-
Vacuum filters; filtration for vacuum
-
PPA filter system; for painting equipment
-
B-AIR filtration; for breathable air
-
Filters in AFS design; silicone-free filtration
-
Accessories for filters; inserts, indications,...
Bestsellers

AAFS microfilter in 3" design to remove micro impurities up to 0.01 um from compressed air according to ISO 8573-1 class 1. Body with easily removable container and designed for...

AAFS microfilter in 3" design to remove micro impurities up to 0.01 um from compressed air according to ISO 8573-1 class 1. Body with easily removable container and designed for...

AAFM pre-filter in 3" design for removal of fine impurities up to 0.1 um from compressed air according to ISO 8573-1 class 2. Body with easily removable container and designed...

AAFP basic filter in 3" design to remove basic mechanical impurities up to 3 um from compressed air according to ISO 8573-1 class 6. Body with easily removable container and...

AAFM pre-filter in 3" design for removal of fine impurities up to 0.1 um from compressed air according to ISO 8573-1 class 2. Body with easily removable container and designed...

AAFC cyclone separator in 3" design with a flow rate of 36,000 l/min for partial removal of condensate from compressed air. Here the flow changes to rotational and due to the...

AAFR dust filter in 3" design to remove dust impurities up to 1 um from compressed air according to ISO 8573-1 class 3. Body with easily removable container and designed for a...

AAFR dust filter in 3" design to remove dust impurities up to 1 um from compressed air according to ISO 8573-1 class 3. Body with easily removable container and designed for a...

AAFB 3" coarse filter to remove the largest mechanical impurities up to 15 um from compressed air according to ISO 8573-1 class 7. Body with easily removable container and...

AAFB 3" coarse filter to remove the largest mechanical impurities up to 15 um from compressed air according to ISO 8573-1 class 7. Body with easily removable container and...

HFPA activated carbon filter with G3" connection thread for use in areas with high corrosive environments. Filtration capacity up to 0.01 um. Maximum working pressure up to 50...

Adsorption filter with activated carbon for compressed air from Hankison NGF series type CF according to ISO. Filter size F17 with 3" female thread connection. The filter is not...

Adsorption filter with activated carbon for compressed air from Hankison NGF series type CF according to ISO. Filter size F16 with 3" internal thread connection. The filter is...

AAFP basic filter in 3" design to remove basic mechanical impurities up to 3 um from compressed air according to ISO 8573-1 class 6. Body with easily removable container and...

Hankison 's NGF series SF type basic ISO filter for compressed air. Filter size F17 with 3" female thread connection. The filter is equipped with a clogging indicator and an...

Hankison 's NGF series SF type basic ISO filter for compressed air. Filter size F16 with 3" internal thread connection. The filter is equipped with a clogging indicator and an...

Hankison 's NGF series NGF type PF basic ISO compressed air filtration. Filter size F17 with 3" female thread connection. The filter is equipped with a clogging indicator and an...

Hankison 's NGF series NGF type PF basic ISO compressed air filtration. Filter size F16 with 3" internal thread connection. The filter is equipped with a clogging indicator and...

The AFSS-2006V filter cartridge, designed for industrial painting applications, eliminates paint deteriorating contaminants. Filtration capacity 0,01 um, maximum working...

Filter cartridge for medical vacuum filter MVAC-2406V. Applications mainly in medical devices. Working pressure 20 to 2000 mbar, maximum flow up to 5750 l/min.

The AFSM-2006 filter cartridge, designed for application in industrial painting, eliminates impurities that degrade paint quality. Filtration capacity 0,1 um, maximum working...

Designed for industrial painting applications, the AFSM-2406 filter cartridge eliminates paint deteriorating contaminants. Filtration capacity 0,1 um, maximum working pressure...

The AFSS-2406V filter cartridge, designed for industrial painting applications, eliminates paint deteriorating contaminants. Filtration capacity 0,01 um, maximum working...

Filter cartridge for medical vacuum filter MVAC-2006V. Applications mainly in medical devices. Working pressure 20 to 2000 mbar, maximum flow up to 4500 l/min.

Filter insert for PVACM vacuum microfilter designed to protect vacuum pumps and vacuum pumps from solid impurities. Filtration capacity up to 0.01 um. Working pressure 20 to...

Filter insert for PVACM vacuum microfilter designed to protect vacuum pumps and vacuum pumps from solid impurities. Filtration capacity up to 0.01 um. Working pressure 20 to...

Filter insert for PVACP vacuum pre-filter designed to protect vacuum pumps and vacuum pumps from solid impurities. Filtration capacity up to 3 um. Working pressure 20 to 2000...

Filter insert for PVACP vacuum pre-filter designed to protect vacuum pumps and vacuum pumps from solid impurities. Filtration capacity up to 3 um. Working pressure 20 to 2000...

AAFA 3" activated carbon filter for absorption of residual oil, oil vapours and aerosols with < 0,005 mg/m3 from compressed air according to ISO 8573-1 class 1. Body with easily...

AAFA 3" activated carbon filter for absorption of residual oil, oil vapours and aerosols with < 0,005 mg/m3 from compressed air according to ISO 8573-1 class 1. Body with easily...

HFPA sterile cartridge filter with G3" connection thread for use in high corrosive environments. Filtration capacity up to 0.01 um. Maximum working pressure up to 50 bar,...

HFPM microfilter with G3" connection thread for use in areas with high corrosive environments. Filtration capacity up to 0.01 um. Maximum working pressure up to 50 bar, maximum...

Microfilter for compressed air from Hankison NGF series UF type according to ISO. Filter size F17 with 3" female thread connection. The filter is equipped with a clogging...

Microfilter for compressed air from Hankison NGF series UF type according to ISO. Filter size F16 with 3" internal thread connection. The filter is equipped with a clogging...

PFM microfilter with G3" connection thread for use in areas with high corrosive environments. Filtration capacity up to 0.1 um. Maximum working pressure is 12 bar, maximum flow...

PFM microfilter with G3" connection thread for use in areas with high corrosive environments. Filtration capacity up to 0.1 um. Maximum working pressure is 12 bar, maximum flow...

PFS microfilter with G3" connection thread for use in areas with high corrosive environments. Filtration capacity up to 0.01 um. Maximum working pressure is 12 bar, maximum...

PFS microfilter with G3" connection thread for use in areas with high corrosive environments. Filtration capacity up to 0.01 um. Maximum working pressure is 12 bar, maximum...

SPFM microfilter with G3" connection thread for high efficiency filtration of compressed air, process air and industrial gases. Filtration capacity up to 0.01 um. Maximum...

SPFM microfilter with G3" connection thread for high efficiency filtration of compressed air, process air and industrial gases. Filtration capacity up to 0.01 um. Maximum...