Get rid of mechanical impurities and oil from compressed air efficiently with our extensive filtration programme. Not only will you get better quality compressed air to suit more applications, but you will also extend the life of many compressor system components. If the above matters to you, please feel free to explore our filtration category properly. You will find Omega Air filters, B-Air filters or NGF and Mark filters. We also offer new filter, catalyst and adsorption inserts for all filters. More about the whole program and filtering principles in the sequel.
#ShowMore#
Why is it necessary to filter compressed air?
The compressed air produced by your compressor - whether piston or screw - is not of good quality without post-treatment and is not suitable for many applications. This is because the compressor inlet filter only captures part of the mechanical impurities. However, they are not the only problem that degrades the quality of the produced air.
What does the produced compressed air contain?
- mechanical impurities
- humidity
- oil vapours (if it is an oil compressor)
This harmful triple combination is causing great trouble for any equipment that is connected to the compressor. Pneumatic tools - over time, they lose power and increase consumption, corrode inside, destroy seals, clog holes, become stuck and negatively affect the quality of work. Its lifetime is shortened many times over. Imagine what untreated compressed air can do to the individual components of a large automated line full of valves, cylinders and variously controlled moving parts. Shutting down a line for servicing can cost a company hundreds of thousands.
Compressed air quality
Compressed air quality is described in standardsiSO 8573-1 with seven classes, from 0 to 6. This guideline is crucial for every operator, as it sets out the exact quality requirements for different applications. Each class has a prescribed maximum content of solids, water and oil. We go into detail about this issue in this article, which will give you advice on how to choose water filters to connect behind your compressor: How to filter compressed air
In addition to the filters themselves, you may also be interested in:
- filter inserts for activated carbon filters
- filter inserts for microfilters
- filter inserts for dust filters
- catalytic filter inserts
- adsorption filter inserts
- air filter cartridge contamination indicators
Filters according to the quality class of solid impurities:
- quality class 1
- quality class 2
- quality class 3
- quality class 4
- quality class 5
- quality class 6
- quality class 7
Industrial filters divided according to condensate discharge:
-
Omega air filters; 16 to 64 bar
-
High pressure filters CHP/IHP; carbon and stainless steel up to 400 bar
-
NGF air filtration; including clogging indication
-
Stainless steel process filters; air and gas distribution
-
Sterile stainless steel filters; SFS and SPF filtration
-
Vacuum filters; filtration for vacuum
-
PPA filter system; for painting equipment
-
B-AIR filtration; for breathable air
-
Filters in AFS design; silicone-free filtration
-
Accessories for filters; inserts, indications,...
Bestsellers
List of products
AAFC cyclone separator in 1 1/2" design with a flow rate of 8,500 l/min for partial removal of condensate from compressed air. Here the flow changes to rotational and due to the...
AAFP basic filter in 1 1/2" design for removal of basic mechanical impurities up to 3 um from compressed air according to ISO 8573-1 class 6. Body with easily removable...
AAFM 1 1/2" pre-filter for removing fine impurities up to 0.1 um from compressed air according to ISO 8573-1 class 2. Body with easily removable container and designed for a...
AAFM 1 1/2" pre-filter for removing fine impurities up to 0.1 um from compressed air according to ISO 8573-1 class 2. Body with easily removable container and designed for a...
AAFR dust filter in 1 1/2" design to remove dust impurities up to 1 um from compressed air according to ISO 8573-1 class 3. Body with easily removable container and designed for...
AAFS 1 1/2" microfilter to remove micro impurities up to 0.01 um from compressed air according to ISO 8573-1 class 1. Body with easily removable container and designed for a...
AAFA activated carbon filter in 1 1/2" version for absorption of residual oil, oil vapours and aerosols with < 0,005 mg/m3 from compressed air according to ISO 8573-1 class 1....
AAFS 1 1/2" microfilter to remove micro impurities up to 0.01 um from compressed air according to ISO 8573-1 class 1. Body with easily removable container and designed for a...
AAFA activated carbon filter in 1 1/2" version for absorption of residual oil, oil vapours and aerosols with < 0,005 mg/m3 from compressed air according to ISO 8573-1 class 1....
MVAC medical vacuum filter with G1 1/2" connection thread designed for effective removal of solid and liquid impurities and bacteria from the suction side of vacuum pumps....
AAFP basic filter in 1 1/2" design for removal of basic mechanical impurities up to 3 um from compressed air according to ISO 8573-1 class 6. Body with easily removable...
AAFR dust filter in 1 1/2" design to remove dust impurities up to 1 um from compressed air according to ISO 8573-1 class 3. Body with easily removable container and designed for...
CHP2A activated carbon filter with G1 1/2" connection thread designed to effectively remove solid impurities, oil, water and other impurities from compressed air up to 0.005 um....
CHP2P basic filter with G1 1/2" connection thread designed to effectively remove solid impurities, oil, water and other impurities from compressed air up to 3 um. Maximum...
Dust filter CHP2R with G1 1/2" connection thread designed to effectively remove dust, oil, water and other impurities from compressed air up to 1 um. Maximum working pressure up...
The CHP2S microfilter with G1 1/2" connection thread is designed to effectively remove solid impurities, oil, water and other impurities from compressed air up to 0.01 um....
CHP2M pre-filter with G1 1/2" connection thread designed for effective removal of solid impurities, oil, water and other impurities from compressed air up to 0.1 um. Maximum...
Adsorption filter with activated carbon for compressed air from Hankison NGF series type CF according to ISO. Filter size F11 with 1 1/2" female threads. The filter is not...
Adsorption filter with activated carbon for compressed air from Hankison NGF series type CF according to ISO. Filter size F10 with 1 1/2" female threads. The filter is not...
Vacuum microfilter PVACM with G1 1/2" connection thread for protection of vacuum pumps and vacuum pumps against solid impurities. Filtration capacity up to 0.01 um. Working...
Vacuum microfilter PVACM with G1 1/2" connection thread for protection of vacuum pumps and vacuum pumps against solid impurities. Filtration capacity up to 0.01 um. Working...
Filter insert for PVACP vacuum pre-filter designed to protect vacuum pumps and vacuum pumps from solid impurities. Filtration capacity up to 3 um. Working pressure 20 to 2000...
Filter insert for PVACP vacuum pre-filter designed to protect vacuum pumps and vacuum pumps from solid impurities. Filtration capacity up to 3 um. Working pressure 20 to 2000...
Vacuum pre-filter PVACP with G1 1/2" connection thread for protection of vacuum pumps and vacuum pumps against solid impurities. Filtration capacity up to 3 um. Working pressure...
Vacuum pre-filter PVACP with G1 1/2" connection thread for protection of vacuum pumps and vacuum pumps against solid impurities. Filtration capacity up to 3 um. Working pressure...
Adsorption filter with activated carbon AAFA2 in 1 1/2" version for absorption of residual oil, oil vapours and aerosols with < 0,005 mg/m3 from compressed air according to ISO...
Adsorption filter with activated carbon AAFA2 in 1 1/2" version for absorption of residual oil, oil vapours and aerosols with < 0,005 mg/m3 from compressed air according to ISO...
AAFB coarse filter in 1 1/2" design to remove the largest mechanical impurities up to 15 um from compressed air according to ISO 8573-1 class 7. Body with easily removable...
AAFB coarse filter in 1 1/2" design to remove the largest mechanical impurities up to 15 um from compressed air according to ISO 8573-1 class 7. Body with easily removable...
Filter insert for PVACM vacuum microfilter designed to protect vacuum pumps and vacuum pumps from solid impurities. Filtration capacity up to 0.01 um. Working pressure 20 to...
Filter insert for PVACM vacuum microfilter designed to protect vacuum pumps and vacuum pumps from solid impurities. Filtration capacity up to 0.01 um. Working pressure 20 to...
AAFMS2 1 1/2" molecular sieve capsule filter designed to prevent moisture leakage into the air during shutdown of adsorption dryers according to ISO 8573-1 class 1. Body with...
AAFMS2 1 1/2" molecular sieve capsule filter designed to prevent moisture leakage into the air during shutdown of adsorption dryers according to ISO 8573-1 class 1. Body with...
HFPA activated carbon filter with G1 1/2" connection thread for use in areas with high corrosive environments. Filtration capacity up to 0.01 um. Maximum working pressure up to...
CHP1A activated carbon filter with G1 1/2" connection thread designed to effectively remove solid impurities, oil, water and other impurities from compressed air up to 0.005 um....
CHP4A activated carbon filter with G1 1/2" connection thread designed to effectively remove solid impurities, oil, water and other impurities from compressed air up to 0.005 um....
The AFA2-130V filter cartridge provides superior breathable air treatment. Filtration provided through activated carbon. Working pressure up to 16 bar, maximum flow rate 13,000...
The AFA2-85V filter cartridge provides superior breathable air treatment. Filtration provided through activated carbon. Working pressure up to 16 bar, maximum flow rate 8500 l/min.
Removes mechanical contaminants up to 3 um in size according to ISO 8573-1 class 6. Connection with internal pipe threads 1 1/2". Designed to allow flow rates up to 6667 l/min....
Removes mechanical contaminants up to 3 um in size according to ISO 8573-1 class 6. Connection with internal pipe threads 1 1/2". The design allows flow rates up to 4700 l/min....