Compressed air filtration pressure 16 to 64 bar, Page 5
-
Professional air filtration AAF; threaded version up to 16 bar
-
Professional air filtration BF; flanged version up to 16 bar
-
HF professional filtration; threaded version up to 50 bar
Bestsellers

Electronic IEDs are primarily designed to drain condensed water from filter vessels. Equipped with LED indicator and test button. Operating temperature +1,5 °C to +65 °C,...

Electronic pressure gauge designed to check and monitor the condition of the filter cartridge. The condition of the filter cartridge is determined by the pressure gradient, the...

Electronic pressure gauge designed to check and monitor the condition of the filter cartridge. The condition of the filter cartridge is determined by the pressure gradient, the...

Float valve for condensate discharge from compressed air system working on float principle. Version AOK16B for internal mounting of filter vessels using 1/2" thread.

Removes mechanical dirt up to 0.01 um and oil according to ISO 8573-1 class 1. Connection by internal pipe threads 1/2". The design allows a flow rate of up to 1187 l/min....

AFM filters are used to remove the largest mechanical impurities from compressed air up to 0.1 um according to ISO 8573-1 class 2. Body with easily removable container and...

Removes mechanical dirt up to 0.1 um and oil according to ISO 8573-1 class 2. Connection by internal pipe threads 1/2". The design allows a flow rate of up to 1187 l/min....

Replacement filter with activated carbon AAFA2 for OMEGA AIR AAFA2-780. Use as a filter to remove residual oil content of oil vapours and aerosols with < 0.005 mg/m3from...

Service kit for condensate evacuator IED for eelectronic IED triggers. The devices are primarily designed to drain condensed water from the filter vessels.

Electronic timed condensate drain for compressed air systems up to 16 bar, operating on a time switching valve. External mounting on the filter body with 1/2" thread. Simple...

AAFA activated carbon filter in 1/2" version for absorption of residual oil, oil vapours and aerosols with < 0,005 mg/m3 from compressed air according to ISO 8573-1 class 1....

Replacement cyclone cartridge for liquid water filtration AAFC-1500V. Recommended replacement 12 months or every 4,000 MH and upon indication of clogging of the filter element...

Replacement basic filter cartridge with 3 µm filtration capacity for OMEGA AIR AAFP-120 filter. Recommended replacement 12 months or every 4,000 MH and when clogging of the...

Replacement fine filter cartridge with 0.1 µm filtration capacity for OMEGA AIR AAFM-1500 and AAFM-1680 pre-filters. Recommended replacement 12 months or every 4,000 MH and when...

AAFC cyclone separator in 3" design with a flow rate of 36,000 l/min for partial removal of condensate from compressed air. Here the flow changes to rotational and due to the...

AAFS 1 1/2" microfilter to remove micro impurities up to 0.01 um from compressed air according to ISO 8573-1 class 1. Body with easily removable container and designed for a...

AAFA 2" activated carbon filter for absorption of residual oil, oil vapours and aerosols with < 0,005 mg/m3 from compressed air according to ISO 8573-1 class 1. Body with easily...

Replacement filter with activated carbon AAFA for OMEGA AIR AAFA-78. Use as a filter to remove residual oil content of oil vapours and aerosols with < 0.005 mg/m3from compressed...

Replacement filter with activated carbon AAFA for OMEGA AIR AAFA-120. Absorption of residual oil, oil vapours and aerosols with a content of < 0.005 mg/m³ from compressed air...

Replacement microfilter cartridge with filtration capacity of 0.01 µm for OMEGA AIR AAFS-120 microfilters. Recommended replacement 12 months or every 4,000 MH and when clogging...

Replacement basic filter cartridge with 3 µm filtration capacity for OMEGA AIR filter AAFP-198. Recommended replacement 12 months or every 4,000 MH and when clogging of the...

Electronic timed condensate drain for compressed air systems up to 50 bar, operating on a time switching valve. External mounting on the filter body with 1/2" thread. Simple...

Removes mechanical contaminants up to 1 um in size according to ISO 8573-1 class 3. Connection by internal pipe threads 1". The design allows a flow rate of up to 3400 l/min....

AAFS 1 1/2" microfilter to remove micro impurities up to 0.01 um from compressed air according to ISO 8573-1 class 1. Body with easily removable container and designed for a...

Removes mechanical dirt up to 0.1 um and oil according to ISO 8573-1 class 2. Connection by internal pipe threads 1". The design allows a flow rate of up to 3400 l/min. Special...

Replacement microfiltration cartridge with filtration capacity of 0.01 µm for OMEGA AIR AAFS-2160 microfilters. Recommended replacement 12 months or every 4,000 MH and when...

AAFM 1 1/2" pre-filter for removing fine impurities up to 0.1 um from compressed air according to ISO 8573-1 class 2. Body with easily removable container and designed for a...

Replacement fine filter cartridge with 0.1 µm filtration capacity for OMEGA AIR AAFM-2160 pre-filter. Recommended replacement 12 months or every 4,000 MH and when clogging of...

Replacement microfiltration cartridge with filtration capacity 0,01 µm for OMEGA AIR AAFS-2760 microfilters. Recommended replacement 12 months or every 4,000 MH and when...

Adsorption filter with activated carbon AAFA2 in 1" version for absorption of residual oil, oil vapours and aerosols with < 0,005 mg/m3 from compressed air according to ISO...

Replacement filter with activated carbon AAFA for OMEGA AIR AAFA-1000. Absorption of residual oil, oil vapours and aerosols with a content of < 0.005 mg/m³ from compressed air...

Replacement basic filter cartridge with 3 µm filtration capacity for OMEGA AIR AAFP-335 filter. Recommended replacement 12 months or every 4,000 MH and when clogging of the...

Electronic timed condensate drain for compressed air systems up to 420 bar, operating on a time switching valve. External mounting on the filter body with 1/4" thread. Simple...

Electronic time release condensate drain with 24V DC voltage from compressed air system up to 420 bar, working on time switching valve. External mounting on the filter body with...

AAFM pre-filter in 2" design for removal of fine impurities up to 0.1 um from compressed air according to ISO 8573-1 class 2. Body with easily removable container and designed...

AAFM pre-filter in 3" design for removal of fine impurities up to 0.1 um from compressed air according to ISO 8573-1 class 2. Body with easily removable container and designed...

AAFMS2 1 1/2" molecular sieve capsule filter designed to prevent moisture leakage into the air during shutdown of adsorption dryers according to ISO 8573-1 class 1. Body with...

AAFMS2 1 1/2" molecular sieve capsule filter designed to prevent moisture leakage into the air during shutdown of adsorption dryers according to ISO 8573-1 class 1. Body with...

Removes mechanical dirt up to 0.01 um and oil according to ISO 8573-1 class 1. Connection by internal pipe threads 1". The design allows a flow rate of up to 3400 l/min. Special...

Removes mechanical dirt up to 0.01 um and oil according to ISO 8573-1 class 1. Connection by internal pipe threads 1/2". The design allows a flow rate of up to 1187 l/min....