Compressed air piping systems
We have simple and very reliable systems of modular piping consisting of pipes, couplings, end boxes and the necessary mounting material, so if you are going to distribute compressed air, both in small workplaces and large halls, we recommend compressed air pipe distribution systems Push Air, SicoAir and AIRnet as the number 1 choice! At the same time, we offer you the possibility of your own design, which we will professionally arrange. If you want more information on both the systems and how to create your own design, click continue.
Piping system design
STEP 1 - system selection
In our catalogue, you can choose from several piping systems that differ in size, connection method, choice of pipe material, working pressure and the medium for which the piping system can be used.
Piping system | SQ | THE | Slovakia |
![]() |
![]() |
![]() |
|
Diameters | 15 - 18 - 22 - 28 | 15 - 18 - 22 - 28 | Ø20 to 158 mm |
Max. clutch pressure | 12.5 bar | 15 bar | 12.5 bar |
Joining | plug connectors | plug connectors | screw nut |
Trumpets | plastic, aluminum | plastic, aluminum | aluminum |
Couplings | nylon PA6 | brass | nylon PA6 |
Media | air | air | air, vacuum, nitrogen |
YEAR 2 - selection of pipe shape
Two concepts are used in the design of the piping architecture: direct and looped piping. The direct line is a simpler and cheaper option, where one backbone pipe runs from the compressor station to the end point. The backbone of the circuit pipe is a closed circuit, which can be additionally filled with further backbone partitions. Despite the significantly higher investment, the circuit line provides significant advantages. The length of the piping route to the furthest point is significantly reduced, which reduces the pressure gradient and allows the compressor to operate at a lower pressure and therefore at a lower energy cost. If shut-off valves are installed on the backbone, it is possible to shut off certain sections of the pipeline if rework and modifications are required.
STEP 3 - Determining the pipe dimensionIn order to determine the required pipe diameter and sizing of couplings, it is useful to create a situation drawing which should include the dimensions of the hall or workshop, the route of the backbone, the individual leads and the location of the shut-off valves. Also determine the expected flow rate in the pipes. Next, plot the starting point and the furthest point to determine the longest distance of the pipeline route. In our case, this distance is 250 m. |
![]() |
Once you have the necessary data, use the piping sizing table found in the introduction to each piping system. In our case, we will use the table for the SR system circuit:
Pipe sizing - SR system |
|||||||||||||
Length | Flow rate (l/min) | ||||||||||||
100 | 200 | 300 | 500 | 750 | 1 000 | 1 500 | 2 000 | 3 000 | 4 000 | 6 000 | 8 000 | 10 000 | |
25 m | 20 | 20 | 20 | 20 | 20 | 20 | 25 | 25 | 32 | 32 | 40 | 40 | 40 |
50 m | 20 | 20 | 20 | 20 | 20 | 20 | 25 | 25 | 32 | 40 | 40 | 40 | 40 |
75 m | 20 | 20 | 20 | 20 | 25 | 25 | 25 | 32 | 32 | 40 | 40 | 40 | 40 |
100 m | 20 | 20 | 20 | 20 | 25 | 25 | 25 | 32 | 40 | 40 | 40 | 40 | 40 |
150 m | 20 | 20 | 20 | 25 | 25 | 25 | 32 | 32 | 40 | 40 | 40 | 40 | 50 |
200 m | 20 | 20 | 20 | 25 | 25 | 25 | 32 | 40 | 40 | 40 | 40 | 40 | 50 |
250 m | 20 | 20 | 20 | 25 | 32 | 32 | 32 | 40 | 40 | 40 | 40 | 50 | 50 |
300 m | 20 | 20 | 20 | 32 | 32 | 32 | 40 | 40 | 40 | 40 | 50 | 50 | 63 |
400 m | 20 | 20 | 25 | 32 | 32 | 32 | 40 | 40 | 40 | 40 | 50 | 50 | 63 |
500 m | 20 | 20 | 25 | 32 | 32 | 40 | 40 | 40 | 40 | 40 | 50 | 63 | 63 |
STEP 4 - Spare length of fittings
The dimension of the pipe is also influenced by the pipe's segmentation. Every bend, turn, fitting or shut-off valve puts resistance to the air flow, creates turbulence and increases the pressure gradient. After the preliminary selection of the dimension from the previous table, it is still necessary to make a correction of the selected dimension using the table and the calculation, the so-called replacement length of the fittings.
Replacement length table fittings | ||||||||||
Piping system | Pipe diameter (mm) | |||||||||
15 | 18 | 20 | 22 | 25 | 28 | 32 | 40 | 50 | 63 | |
Knee | 0,7 | 1,0 | 1,2 | 1,3 | 1,4 | 1,5 | 1,7 | 2,0 | 2,5 | 3,5 |
T-piece | 0,8 | 1,0 | 1,4 | 1,5 | 1,8 | 2,0 | 2,1 | 2,5 | 3,0 | 4,0 |
Reduction 2D --> D | 0,4 | 0,5 | 0,5 | 0,5 | 0,6 | 0,6 | 0,7 | 0,7 | 0,8 | 1,0 |
Ball cock | 0,1 | 0,2 | 0,3 | 0,3 | 0,4 | 0,4 | 0,5 | 0,5 | 0,6 | 0,7 |
Example: | 1 × elbow | 1 × 2.0 m = 2.0 m |
8 × T-piece | 8 × 2.5 m = 20.0 m | |
4 × ball valve | 4 × 0,5 m = 2,0 m |
The total replacement length of the fittings is 24 m.
Now we re-determine the pipe dimension in step 3 for a new length of 250 + 24 = 274 m.
From the reading we can see that the pipe dimension has not changed and remains 40 mm.
IMPORTANT NOTICE !
The values shown are for compressed air, working pressure 7 bar and maximum pressure gradient 0.5 bar. For other operating conditions, please contact us and we will be happy to prepare an individual design of the piping solution.
Compressed air distribution systems:
- TA - simple system of threaded pipes and couplings for workshops and industrial plants with pipes from 15 to 28 mm
- AIRnet - a high-end connection system that can be installed by a single worker, made of lightweight aluminium tubes with outer diameters from 20 to 63 mm
- SR - extremely efficient modular system with minimal pressure gradient for compressed air distribution in craft and industry
- SICOalu2 - aesthetically perfect, modular system for craft and maintenance workshops, car and tyre workshops, laboratories
- SICO110 - modular system with large aluminium profiles for large compressed air installations
How to design a compressed air distribution system
- Start with a plan of your operation, plotting compressor locations, obstructions and take-off points
- Choose direct (lower acquisition costs) or looped (closed loop suitable for larger plants, slightly higher costs)
- Determine the maximum consumption
- Choose from the above modular systems which suits your operation best
- Determine the diameter of the pipes and fasteners
- If anything is difficult for you, please do not hesitate to let us know on +420 311 532 091 or info@kompresory-vzduchotechnika.cz, we will be happy to advise you
What else you can use when distributing air:
📏 We offer piping in the following diameters:
-
Pipework TA 15 - 28 mm dimensions
-
SQ piping 15 - 28 mm dimensions
-
SICOAIR piping with union nut 20 - 63 mm
-
AIRnet piping 20 - 63 mm dimensions
-
SICOALU2 piping aluminium profiles
-
Piping SICO110 aluminium profiles large
best-selling products

Plastic pipe PA12 for compressed air piping. Pipe size 22/18 mm with recommended operating pressure 13 bar. Classic blue colour as marking for air ducts. Easy connection with...

90° elbow of the Classic AIRnet series with a clearance of 63 mm. The couplings are characterised by their simple assembly. Operating pressure 13 bar, operating temperature -20...

AIRnet tap with thread G3/4" - 63 mm. The couplings are characterised by their simple and quick assembly. Operating pressure 13 bar, operating temperature -20 to +70 °C. UV,...

AIRnet Classic straight coupling with 63 mm clearance. The couplings are characterised by their simple assembly. Operating pressure 13 bar, operating temperature -20 to +70 °C....

T-coupling of the Classic AIRnet series with a clearance of 63 mm. The couplings are characterised by their simple and quick assembly. Operating pressure 13 bar, operating...

Airnet 25 mm pipe clamp. The entire Airnet system is easy to install. Operating pressure 13 bar, operating temperature -20 to +70 °C. UV, oil and corrosion resistant.

Bracket mounting arm 300 mm wide. The entire Airnet system is easy to install. Operating pressure 13 bar, operating temperature -20 to +70 °C. UV, oil and corrosion resistant.

Modern aluminium piping for compressed air in blue colour. Diameter 20/17.4 mm with operating pressure 13 bar, operating temperature -20 to +70 °C. UV, oil and corrosion...

Flange support for 100 mm dimension. The system is characterised by its simple and quick installation. Operating pressure 13 bar, operating temperature -20 to +70 °C.

Modern aluminium piping for compressed air in blue colour. Diameter 25/22.2 mm with operating pressure 13 bar, operating temperature -20 to +70 °C. UV, oil and corrosion...

Airnet end box G1/2", 20 mm clearance. The couplings are characterised by their simple and quick assembly. Operating pressure 13 bar, operating temperature -20 to +70 °C. UV,...

40 mm AIRnet plug of the PF series. The couplings are characterised by their simple and quick assembly. Operating pressure 13 bar, operating temperature -20 to +70 °C. UV, oil...

45° elbow of the PF AIRnet series with 40 mm clearance. The couplings are characterised by their simple assembly. Operating pressure 13 bar, operating temperature -20 to +70 °C....

Tap with coupling series PF AIRnet 20 - 50 mm. The couplings are characterised by their simple and quick assembly. Operating pressure 13 bar, operating temperature -20 to +70...

Airnet pipe clamp 80 mm. The entire Airnet system is easy to install. Operating pressure 13 bar, operating temperature -20 to +70 °C. UV, oil and corrosion resistant.

90° elbow of the PF AIRnet series with a clearance of 20 mm. The couplings are characterised by their simple assembly. Operating pressure 13 bar, operating temperature -20 to...

T-coupling series PF AIRnet with G1/2" thread and 25 mm coupling. The couplings are characterised by their simple and quick assembly. Operating pressure 13 bar, operating...

Connecting adapter Airnet G1", 40 mm clearance. The couplings are characterised by their simple and quick assembly. Operating pressure 13 bar, operating temperature -20 to +70...

Modern aluminium pipework for inert gases, green in colour, 5.7 m long. Diameter 25/22 mm with operating pressure 13 bar, operating temperature -20 to +70 °C. UV, oil and...

AIRnet tap with thread G1/2" - 25 mm. The couplings are characterised by their simple and quick assembly. Operating pressure 13 bar, operating temperature -20 to +70 °C. UV,...

Reduced T-coupling series PF AIRnet with a clearance of 50 - 20 mm. The couplings are characterised by their simple and quick assembly. Operating pressure 13 bar, operating...

Reduced T-coupling series PF AIRnet with a clearance of 50 - 25 mm. The couplings are characterised by their simple and quick assembly. Operating pressure 13 bar, operating...

Tap with coupling series PF AIRnet 25 - 80 mm. The couplings are characterised by their simple and quick assembly. Operating pressure 13 bar, operating temperature -20 to +70...

Classic AIRnet T-coupling with G2" thread and 63 mm coupling. The couplings are characterised by their simple and quick assembly. Operating pressure 13 bar, operating...

Detachable coupling with external thread G3/4", clearance 20 mm. The couplings are characterised by their simple and quick assembly. Operating pressure 13 bar, operating...

AIRnet plug PF 63 mm series. The couplings are characterised by their simple and quick assembly. Operating pressure 13 bar, operating temperature -20 to +70 °C. UV, oil and...

T-coupling series PF AIRnet with G3/4" thread and 25 mm coupling. The couplings are characterised by their simple and quick assembly. Operating pressure 13 bar, operating...

Airnet clamp base for pipes 40 - 50 mm. The entire Airnet system is easy to install. Operating pressure 13 bar, operating temperature -20 to +70 °C. UV, oil and corrosion...

AIRnet straight coupling with R2" - 63 mm male thread. The couplings are characterised by their simple and quick assembly. Operating pressure 13 bar, operating temperature -20...

AIRnet straight coupling with external thread R2 1/2" - 63 mm. The couplings are characterised by their simple and quick assembly. Operating pressure 13 bar, operating...

Connecting adapter Airnet G1 1/2", 50 mm clearance. The couplings are characterised by their simple and quick assembly. Operating pressure 13 bar, operating temperature -20 to...

big AIRnet 90° elbow with 100 mm clearance. The couplings are characterised by their simple assembly. Operating pressure 13 bar, operating temperature -20 to +70 °C. UV, oil...

AIRnet Classic series reducers with 50 - 63 mm clearance. The reducers are characterised by their simple assembly. Operating pressure 13 bar, operating temperature -20 to +70...

Shut-off valve with 80 mm coupling and G3" thread. The system is characterised by its simple and quick installation. Operating pressure 13 bar, operating temperature -20 to +70...

Ball valve series PF Airnet with 40 mm couplings. The system is characterised by its simple and quick installation. Operating pressure 13 bar, operating temperature -20 to +70...

AIRnet flexible hose with a diameter of 80 mm and a length of 1500 mm. Direct design with flange connection DN160. The entire Airnet system is easy to install. Operating...

Classic AIRnet T-coupling with a clearance of 80 mm. The couplings are characterised by their simple and quick assembly. Operating pressure 13 bar, operating temperature -20 to...

T-coupling series PF AIRnet with G2 1/2" thread and 80 mm coupling. The couplings are characterised by their simple and quick assembly. Operating pressure 13 bar, operating...

Ball valve series PF Airnet with G2" thread and 50 mm coupling. The system is characterised by its simple and quick installation. Operating pressure 13 bar, operating...

AIRnet straight coupling with external thread R3" - 80 mm. The couplings are characterised by their simple and quick assembly. Operating pressure 13 bar, operating temperature...