Filtration, regulation and treatment of compressed air, Page 8
-
Treatment units; basic units for air
-
Industrial filtration; ISO 8573 - ISO 12500
-
Air dryers; air moisture removal
-
Pressure regulators; precision robust design
-
Cyclone separators; cyclone filtration principle
-
Water-oil separators; separates water from oil
Bestsellers

Hankison filter cartridge for the PF series air filter type F04. The filter insert is suitable for easy replacement by means of a thread in the filter. The maximum pressure of...

Basic 5 um air filter with 1/2" connection for compressed air and neutral gases with a flow rate of 3,500 l/min. Design according to ATEX II 2G2D. Maximum inlet pressure 1,5 -...

Shut-off valve in 3/8" design with flow rate up to 4 500 l/min FUTURA series up to 16 bar. Designed for compressed air and for neutral gases complying with ATEX II 2G2D....

Metal filter for filtration of compressed air from a compressor at 20 um to 18 bar with a maximum flow rate of 11,000 l/min. Connection 1" pipe thread. Possibility to change the...

Compressed air treatment units in metal design up to 18 bar. Lubricator in 1" size with a flow rate of up to 16,000 l/min for compressed air lubrication of e.g. pneumatic tools....

Compressed air treatment units in metal design with inlet up to 18 bar. Compressed air control 0 - 12 bar with a flow rate of 4,500 l/min in 1" size. Application mainly in...

Compressed air condensation dryer for dew point +3°C. Maximum inlet pressure is 14 bar with a flow rate of up to 380 m³/hr (6,333 l/min) and connection via G1 1/4" male thread....

The filters are used to remove the largest mechanical impurities from compressed air up to 1 um according to ISO 8573-1 class 3. Body with easily removable container and...

Hankison filter cartridge for SF series air filter type F02. The filter insert is suitable for easy replacement by means of a thread in the filter. The maximum pressure of the...

Hankison filter cartridge for SF series air filter type F03. The filter insert is suitable for easy replacement by means of a thread in the filter. The maximum pressure of the...

Prefilter for compressed air from Hankison NGF series of HF type according to ISO. Filter size F08 with 1" female thread connection. The filter is equipped with a clogging...

Futura Treatment Units - Compressed Air Pressure Regulators, Designed for compressed air with or without oil and for neutral gases, Designed according to ATEX II 2G2D, Maximum...

Replacement dust filter cartridge with 1 µm filtration capacity for OMEGA AIR AAFR-198 filter. Recommended replacement 12 months or every 4,000 MH and when clogging of the...

Replacement dust filter cartridge with 1 µm filtration capacity for OMEGA AIR AAFR-335. Recommended replacement 12 months or every 4,000 MH and when clogging of the filter...

Replacement dust filter cartridge with 1 µm filtration capacity for OMEGA AIR AAFR-510 filter. Recommended replacement 12 months or every 4,000 MH and when clogging of the...

Replacement dust filter cartridge with 1 µm filtration capacity for OMEGA AIR AAFR-780. Recommended replacement 12 months or every 4,000 MH and when clogging of the filter...

Absorption filter with 0.005 um activated carbon, 3/8" connection, for compressed air and neutral gases with a flow rate of 700 l/min. Design according to ATEX II 2G2D. Maximum...

Replacement basic filter cartridge with 3 µm filtration capacity for OMEGA AIR AAFP-780 filter. Recommended replacement 12 months or every 4,000 MH and when clogging of the...

Hankison 's NGF series NGF type PF basic ISO compressed air filtration. Filter size F03 with 3/8" female threads. The filter is equipped with a clogging indicator and an...

Basic AFP filters according to ISO 8573.1 with a filtration capacity of 3 um and an efficiency of 99.9%. FPRO filters are used to remove the largest mechanical impurities from...

Replacement fine filter cartridge with 0.1 µm filtration capacity for OMEGA AIR AAFM-335 pre-filter. Recommended replacement 12 months or every 4,000 MH and when clogging of the...

Replacement fine filter cartridge with 0.1 µm filtration capacity for OMEGA AIR AAFM-510 pre-filter. Recommended replacement 12 months or every 4,000 MH and when clogging of the...

Replacement fine filter cartridge with 0.1 µm filtration capacity for OMEGA AIR AAFM-780 pre-filter. Recommended replacement 12 months or every 4,000 MH and when clogging of the...

Compressed air condensation dryer for dew point +3°C. The maximum inlet pressure is 14 bar with a flow rate of up to 100 m³/hr (1,666 l/min) and connection via a G3/4" male...

Metal filter for filtration of compressed air from a compressor at 20 um to 18 bar with a maximum flow of 1,300 l/min. Connection 1/4" pipe thread. Possibility to change the...

Futura Treatment Units - Compressed Air Pressure Regulators, Designed for compressed air with or without oil and for neutral gases, Designed according to ATEX II 2G2D, Maximum...

Filter cartridge for HFR filter to remove mechanical impurities from compressed air. Acrylic fibre and cellulose liner with a filtration capacity of up to 1 μm. Working pressure...

Futura Treatment Units - Compressed Air Pressure Regulators, Designed for compressed air with or without oil and for neutral gases, Designed according to ATEX II 2G2D, Maximum...

Replacement filter with activated carbon AAFA2 for OMEGA AIR AAFA2-78. Use as a filter to remove residual oil content of oil vapours and aerosols with < 0.005 mg/m3from...

Replacement microfiltration cartridge with filtration capacity of 0.01 µm for OMEGA AIR AAFS-2160 microfilters. Recommended replacement 12 months or every 4,000 MH and when...

The HFS filter insert removes mechanical impurities and oil from the compressed air. Borosilicate microfibre insert with a filtration capacity of up to 0.01 μm. Working pressure...

Replacement diaphragm for A2 - A2MR-12 pressure regulators. Simple diaphragm exchange for re-adjusting the air pressure from 0.5 - 8 bar. Suitable for the following units :...

AAFP basic filter in 3/8" design to remove basic mechanical impurities up to 3 um from compressed air according to ISO 8573-1 class 6. Body with easily removable container and...

AAFP basic filter in 1/4" design for removal of basic mechanical impurities up to 3 um from compressed air according to ISO 8573-1 class 6. Body with easily removable container...

AAFP basic filter in 3/8" design to remove basic mechanical impurities up to 3 um from compressed air according to ISO 8573-1 class 6. Body with easily removable container and...

Hankison filter cartridge for UF series air microfilter type F10. The filter insert is suitable for easy replacement by means of a thread in the filter. The maximum pressure of...

AAFP 1" basic filter for removal of basic mechanical impurities up to 3 um from compressed air according to ISO 8573-1 class 6. Body with easily removable container and designed...

Regulators for pressure reduction of compressed air and other non-volatile and non-toxic gases. Maximum inlet pressure 40 bar, various outlet pressures, operating temperature...

Replacement cartridge WOS-8A for water-oil separators. Active carbon filtration. Residual oil less than 10 ppm. The maximum flow rate is 8000 l/min.

Replacement cartridge WOS-8P for water-oil separators. Filtration via PP filter insert. Residual oil less than 10 ppm. The maximum flow rate is 8000 l/min.